{"title":"A screen-printed carbon electrode immobilized MXene-gold nanoparticles composite detects creatinine in micro-volume of human serum samples","authors":"Monika Chhillar , Poornima Bhatt , Anup Singh , Deepak Kukkar , Ashok Kumar , Ashok Kumar Yadav","doi":"10.1016/j.biosx.2025.100710","DOIUrl":null,"url":null,"abstract":"<div><div>Creatinine (CR), a non-protein nitrogenous compound, serves as an important clinical indicator for assessing renal function. This research reports the application of screen-printed electrodes modified with Ti<sub>3</sub>C<sub>2</sub>-based MXene-gold nanocomposites (SPCE/MXene/AuNPs) for the precise quantification of CR in human serum. The SPCE/MXene/AuNPs sensor leverages its interactions with CR to enhance redox electrochemical signals, leading to their amplified detection sensitivity. Under optimal conditions (pH 7.4), the SPCE/MXene/AuNPs sensor exhibited excellent analytical performance, with a linear detection range of 0.1–11 mg dL<sup>−1</sup>, a high correlation coefficient (R<sup>2</sup> = 0.99), and calculated detection and quantification limits of 0.018 mg dL<sup>−1</sup> and 0.06 mg dL<sup>−1</sup>, respectively. Additionally, these electrodes demonstrated minimal interference from common physiological compounds (glucose, ascorbic acid, glutathione, bilirubin, gentamicin, vancomycin, arginine globulin, histidine, urea, bovine serum albumin (BSA), and electrolytes [K<sup>+</sup>, Ca<sup>2+</sup>, SO<sub>4</sub><sup>2−</sup>, and Mg<sup>2+</sup>]). Furthermore, the developed sensor demonstrated excellent correlation (R<sup>2</sup> = 0.99) with the standard Jaffe method for CR assessment in human serum samples (n = 89) with a mean difference of −0.136 mg dL<sup>−1</sup> (95 % CI: 0.190 to −0.081 mg dL<sup>−1</sup>) and significant agreement confirmed by paired <em>t</em>-test (p < 0.0001). Only four samples exhibited false negatives (3.58, 3.02, 9.50, and 11.25 %). The sensor retained 94.7 % of its initial response after 15 days at 4 °C, and reproducibility was confirmed via overlapping CV cycles. Our investigation demonstrates the potential of our electrochemical sensor for accurate and reliable CR measurement in complex biological matrices.</div></div>","PeriodicalId":260,"journal":{"name":"Biosensors and Bioelectronics: X","volume":"27 ","pages":"Article 100710"},"PeriodicalIF":10.6100,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590137025001372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0
Abstract
Creatinine (CR), a non-protein nitrogenous compound, serves as an important clinical indicator for assessing renal function. This research reports the application of screen-printed electrodes modified with Ti3C2-based MXene-gold nanocomposites (SPCE/MXene/AuNPs) for the precise quantification of CR in human serum. The SPCE/MXene/AuNPs sensor leverages its interactions with CR to enhance redox electrochemical signals, leading to their amplified detection sensitivity. Under optimal conditions (pH 7.4), the SPCE/MXene/AuNPs sensor exhibited excellent analytical performance, with a linear detection range of 0.1–11 mg dL−1, a high correlation coefficient (R2 = 0.99), and calculated detection and quantification limits of 0.018 mg dL−1 and 0.06 mg dL−1, respectively. Additionally, these electrodes demonstrated minimal interference from common physiological compounds (glucose, ascorbic acid, glutathione, bilirubin, gentamicin, vancomycin, arginine globulin, histidine, urea, bovine serum albumin (BSA), and electrolytes [K+, Ca2+, SO42−, and Mg2+]). Furthermore, the developed sensor demonstrated excellent correlation (R2 = 0.99) with the standard Jaffe method for CR assessment in human serum samples (n = 89) with a mean difference of −0.136 mg dL−1 (95 % CI: 0.190 to −0.081 mg dL−1) and significant agreement confirmed by paired t-test (p < 0.0001). Only four samples exhibited false negatives (3.58, 3.02, 9.50, and 11.25 %). The sensor retained 94.7 % of its initial response after 15 days at 4 °C, and reproducibility was confirmed via overlapping CV cycles. Our investigation demonstrates the potential of our electrochemical sensor for accurate and reliable CR measurement in complex biological matrices.
期刊介绍:
Biosensors and Bioelectronics: X, an open-access companion journal of Biosensors and Bioelectronics, boasts a 2020 Impact Factor of 10.61 (Journal Citation Reports, Clarivate Analytics 2021). Offering authors the opportunity to share their innovative work freely and globally, Biosensors and Bioelectronics: X aims to be a timely and permanent source of information. The journal publishes original research papers, review articles, communications, editorial highlights, perspectives, opinions, and commentaries at the intersection of technological advancements and high-impact applications. Manuscripts submitted to Biosensors and Bioelectronics: X are assessed based on originality and innovation in technology development or applications, aligning with the journal's goal to cater to a broad audience interested in this dynamic field.