{"title":"A screen-printed carbon electrode immobilized MXene-gold nanoparticles composite detects creatinine in micro-volume of human serum samples","authors":"Monika Chhillar ,&nbsp;Poornima Bhatt ,&nbsp;Anup Singh ,&nbsp;Deepak Kukkar ,&nbsp;Ashok Kumar ,&nbsp;Ashok Kumar Yadav","doi":"10.1016/j.biosx.2025.100710","DOIUrl":null,"url":null,"abstract":"<div><div>Creatinine (CR), a non-protein nitrogenous compound, serves as an important clinical indicator for assessing renal function. This research reports the application of screen-printed electrodes modified with Ti<sub>3</sub>C<sub>2</sub>-based MXene-gold nanocomposites (SPCE/MXene/AuNPs) for the precise quantification of CR in human serum. The SPCE/MXene/AuNPs sensor leverages its interactions with CR to enhance redox electrochemical signals, leading to their amplified detection sensitivity. Under optimal conditions (pH 7.4), the SPCE/MXene/AuNPs sensor exhibited excellent analytical performance, with a linear detection range of 0.1–11 mg dL<sup>−1</sup>, a high correlation coefficient (R<sup>2</sup> = 0.99), and calculated detection and quantification limits of 0.018 mg dL<sup>−1</sup> and 0.06 mg dL<sup>−1</sup>, respectively. Additionally, these electrodes demonstrated minimal interference from common physiological compounds (glucose, ascorbic acid, glutathione, bilirubin, gentamicin, vancomycin, arginine globulin, histidine, urea, bovine serum albumin (BSA), and electrolytes [K<sup>+</sup>, Ca<sup>2+</sup>, SO<sub>4</sub><sup>2−</sup>, and Mg<sup>2+</sup>]). Furthermore, the developed sensor demonstrated excellent correlation (R<sup>2</sup> = 0.99) with the standard Jaffe method for CR assessment in human serum samples (n = 89) with a mean difference of −0.136 mg dL<sup>−1</sup> (95 % CI: 0.190 to −0.081 mg dL<sup>−1</sup>) and significant agreement confirmed by paired <em>t</em>-test (p &lt; 0.0001). Only four samples exhibited false negatives (3.58, 3.02, 9.50, and 11.25 %). The sensor retained 94.7 % of its initial response after 15 days at 4 °C, and reproducibility was confirmed via overlapping CV cycles. Our investigation demonstrates the potential of our electrochemical sensor for accurate and reliable CR measurement in complex biological matrices.</div></div>","PeriodicalId":260,"journal":{"name":"Biosensors and Bioelectronics: X","volume":"27 ","pages":"Article 100710"},"PeriodicalIF":10.6100,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590137025001372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

Abstract

Creatinine (CR), a non-protein nitrogenous compound, serves as an important clinical indicator for assessing renal function. This research reports the application of screen-printed electrodes modified with Ti3C2-based MXene-gold nanocomposites (SPCE/MXene/AuNPs) for the precise quantification of CR in human serum. The SPCE/MXene/AuNPs sensor leverages its interactions with CR to enhance redox electrochemical signals, leading to their amplified detection sensitivity. Under optimal conditions (pH 7.4), the SPCE/MXene/AuNPs sensor exhibited excellent analytical performance, with a linear detection range of 0.1–11 mg dL−1, a high correlation coefficient (R2 = 0.99), and calculated detection and quantification limits of 0.018 mg dL−1 and 0.06 mg dL−1, respectively. Additionally, these electrodes demonstrated minimal interference from common physiological compounds (glucose, ascorbic acid, glutathione, bilirubin, gentamicin, vancomycin, arginine globulin, histidine, urea, bovine serum albumin (BSA), and electrolytes [K+, Ca2+, SO42−, and Mg2+]). Furthermore, the developed sensor demonstrated excellent correlation (R2 = 0.99) with the standard Jaffe method for CR assessment in human serum samples (n = 89) with a mean difference of −0.136 mg dL−1 (95 % CI: 0.190 to −0.081 mg dL−1) and significant agreement confirmed by paired t-test (p < 0.0001). Only four samples exhibited false negatives (3.58, 3.02, 9.50, and 11.25 %). The sensor retained 94.7 % of its initial response after 15 days at 4 °C, and reproducibility was confirmed via overlapping CV cycles. Our investigation demonstrates the potential of our electrochemical sensor for accurate and reliable CR measurement in complex biological matrices.

Abstract Image

丝网印刷碳电极固定化mxene -金纳米颗粒复合材料检测微量人血清样品中的肌酐
肌酐(CR)是一种非蛋白氮化合物,是评价肾功能的重要临床指标。本研究报道了用ti3c2基MXene-金纳米复合材料(SPCE/MXene/AuNPs)修饰的丝网印刷电极用于人血清中CR的精确定量。SPCE/MXene/AuNPs传感器利用其与CR的相互作用来增强氧化还原电化学信号,从而提高了检测灵敏度。在最优条件(pH 7.4)下,SPCE/MXene/AuNPs传感器具有良好的分析性能,线性检测范围为0.1 ~ 11 mg dL−1,相关系数高(R2 = 0.99),计算检测限和定量限分别为0.018 mg dL−1和0.06 mg dL−1。此外,这些电极显示最小的干扰,从常见的生理化合物(葡萄糖,抗坏血酸,谷胱甘肽,胆红素,庆大霉素,万古霉素,精氨酸球蛋白,组氨酸,尿素,牛血清白蛋白(BSA)和电解质[K+, Ca2+, SO42−,和Mg2+])。此外,开发的传感器与人类血清样本(n = 89)中CR评估的标准Jaffe方法具有良好的相关性(R2 = 0.99),平均差异为- 0.136 mg dL - 1 (95% CI: 0.190至- 0.081 mg dL - 1),配对t检验证实了显著的一致性(p < 0.0001)。只有4个样本出现假阴性(3.58%、3.02、9.50和11.25%)。在4°C温度下,传感器在15天后保持了94.7%的初始响应,并且通过重叠的CV循环确认了重复性。我们的研究证明了我们的电化学传感器在复杂生物基质中精确可靠的CR测量的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biosensors and Bioelectronics: X
Biosensors and Bioelectronics: X Biochemistry, Genetics and Molecular Biology-Biophysics
CiteScore
4.60
自引率
0.00%
发文量
166
审稿时长
54 days
期刊介绍: Biosensors and Bioelectronics: X, an open-access companion journal of Biosensors and Bioelectronics, boasts a 2020 Impact Factor of 10.61 (Journal Citation Reports, Clarivate Analytics 2021). Offering authors the opportunity to share their innovative work freely and globally, Biosensors and Bioelectronics: X aims to be a timely and permanent source of information. The journal publishes original research papers, review articles, communications, editorial highlights, perspectives, opinions, and commentaries at the intersection of technological advancements and high-impact applications. Manuscripts submitted to Biosensors and Bioelectronics: X are assessed based on originality and innovation in technology development or applications, aligning with the journal's goal to cater to a broad audience interested in this dynamic field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书