Kendall Benton, Emma Orcutt, Skyler Hollinbeck, Erik M. Grumstrup
{"title":"Optimizing Detection Schemes for Broadband Pump-Probe Microscopy","authors":"Kendall Benton, Emma Orcutt, Skyler Hollinbeck, Erik M. Grumstrup","doi":"10.1002/jemt.70092","DOIUrl":null,"url":null,"abstract":"<p>Although similar to more commonly implemented single wavelength approaches, broadband pump-probe or transient absorption microscopy presents unique experimental challenges due to the simultaneous requirements of a broadband probe pulse and a small sample volume. Here we provide an in-depth analysis of broadband detection schemes and their common noise sources to provide strategies for balancing the conflicting needs of high sensitivity and low probe fluence. We show that broadband pump-probe microscopy is atypically sensitive to laser shot noise and therefore, low pump on/off modulation frequencies, on the order of 100 s of Hz to a few kHz, are essential to measure small (<span></span><math>\n <semantics>\n <mrow>\n <mo>~</mo>\n <msup>\n <mn>10</mn>\n <mrow>\n <mo>−</mo>\n <mn>3</mn>\n </mrow>\n </msup>\n <mo>−</mo>\n <msup>\n <mn>10</mn>\n <mrow>\n <mo>−</mo>\n <mn>4</mn>\n </mrow>\n </msup>\n </mrow>\n </semantics></math>) amplitude transient spectra while remaining in the perturbative limit.</p>","PeriodicalId":18684,"journal":{"name":"Microscopy Research and Technique","volume":"89 4","pages":"551-556"},"PeriodicalIF":2.1000,"publicationDate":"2026-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12997396/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy Research and Technique","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jemt.70092","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ANATOMY & MORPHOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Although similar to more commonly implemented single wavelength approaches, broadband pump-probe or transient absorption microscopy presents unique experimental challenges due to the simultaneous requirements of a broadband probe pulse and a small sample volume. Here we provide an in-depth analysis of broadband detection schemes and their common noise sources to provide strategies for balancing the conflicting needs of high sensitivity and low probe fluence. We show that broadband pump-probe microscopy is atypically sensitive to laser shot noise and therefore, low pump on/off modulation frequencies, on the order of 100 s of Hz to a few kHz, are essential to measure small () amplitude transient spectra while remaining in the perturbative limit.
期刊介绍:
Microscopy Research and Technique (MRT) publishes articles on all aspects of advanced microscopy original architecture and methodologies with applications in the biological, clinical, chemical, and materials sciences. Original basic and applied research as well as technical papers dealing with the various subsets of microscopy are encouraged. MRT is the right form for those developing new microscopy methods or using the microscope to answer key questions in basic and applied research.