Use of a spot-check protocol to measure ventricular response rate in dogs with atrial fibrillation

IF 1.5 2区 农林科学 Q2 VETERINARY SCIENCES
Journal of Veterinary Cardiology Pub Date : 2026-02-01 Epub Date: 2025-10-14 DOI:10.1016/j.jvc.2025.10.002
M.I. Oliveira, G. Culshaw, S.-A. Dickson, R. Blake, Y. Martinez Pereira
{"title":"Use of a spot-check protocol to measure ventricular response rate in dogs with atrial fibrillation","authors":"M.I. Oliveira,&nbsp;G. Culshaw,&nbsp;S.-A. Dickson,&nbsp;R. Blake,&nbsp;Y. Martinez Pereira","doi":"10.1016/j.jvc.2025.10.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction/Objectives</h3><div>Fast ventricular response rates (VRRs) have negative prognostic value in atrial fibrillation (AF). Therapeutic recommendations for canine AF rely on measurements of VRR from ambulatory electrocardiograms (aECGs).</div></div><div><h3>Animals, Materials and methods</h3><div>Data from aECG of dogs with AF were prospectively acquired alongside VRR measurements obtained at home using a smartphone-based ECG device between 7:00 and 23:00. From these data, three protocols were outlined: (A) three eight-hourly spot-checks, (B) three six-hourly spot-checks, and (C) five predetermined spot-checks. The performance of the protocols was compared with aECG using mesor, mean and median VRR. The presence of circadian variation was explored using cosinor analysis.</div></div><div><h3>Results</h3><div>Eighteen aECGs were analysed, and 14 were used to test the spot-check protocols. The protocols showed moderate to strong correlation with aECG, with protocol B performing best (mean, r = 0.84, P=&lt;0.0001, bias −22.96, limits of agreement 24.4; median, r = 0.90, P=&lt;0.0001, bias −24.48, limits of agreement 22.04). Using a mean VRR &lt;125 beats per minute (bpm) as cut-off, 10 of 14 dogs (71.4%) had inadequate VRR control. All protocols correctly identified these dogs, with protocol A performing best for mean VRR &gt;140 bpm. Circadian variation in VRR was identified in 17 of 18 dogs (94%).</div></div><div><h3>Limitations</h3><div>This study is limited by the small population, highly prevalent inadequate VRR, non-standardised treatment, measurement artefacts and precise temporal alignment with aECG.</div></div><div><h3>Conclusions</h3><div>Spot-check protocols offer a practical, affordable alternative to aECG for VRR assessment in dogs with AF. We have established that mean VRR &gt;140 bpm in the protocol predicts inadequate rate control on aECG.</div></div>","PeriodicalId":48788,"journal":{"name":"Journal of Veterinary Cardiology","volume":"63 ","pages":"Pages 16-27"},"PeriodicalIF":1.5000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Cardiology","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1760273425001092","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction/Objectives

Fast ventricular response rates (VRRs) have negative prognostic value in atrial fibrillation (AF). Therapeutic recommendations for canine AF rely on measurements of VRR from ambulatory electrocardiograms (aECGs).

Animals, Materials and methods

Data from aECG of dogs with AF were prospectively acquired alongside VRR measurements obtained at home using a smartphone-based ECG device between 7:00 and 23:00. From these data, three protocols were outlined: (A) three eight-hourly spot-checks, (B) three six-hourly spot-checks, and (C) five predetermined spot-checks. The performance of the protocols was compared with aECG using mesor, mean and median VRR. The presence of circadian variation was explored using cosinor analysis.

Results

Eighteen aECGs were analysed, and 14 were used to test the spot-check protocols. The protocols showed moderate to strong correlation with aECG, with protocol B performing best (mean, r = 0.84, P=<0.0001, bias −22.96, limits of agreement 24.4; median, r = 0.90, P=<0.0001, bias −24.48, limits of agreement 22.04). Using a mean VRR <125 beats per minute (bpm) as cut-off, 10 of 14 dogs (71.4%) had inadequate VRR control. All protocols correctly identified these dogs, with protocol A performing best for mean VRR >140 bpm. Circadian variation in VRR was identified in 17 of 18 dogs (94%).

Limitations

This study is limited by the small population, highly prevalent inadequate VRR, non-standardised treatment, measurement artefacts and precise temporal alignment with aECG.

Conclusions

Spot-check protocols offer a practical, affordable alternative to aECG for VRR assessment in dogs with AF. We have established that mean VRR >140 bpm in the protocol predicts inadequate rate control on aECG.
使用抽查方案测量心房颤动犬的心室反应率。
简介/目的:快速心室反应率(VRRs)对房颤(AF)有负面预后价值。犬房颤的治疗建议依赖于动态心电图(aECGs)的VRR测量。动物、材料和方法:前瞻性地获取AF犬的aECG数据,并在7:00至23:00期间使用基于智能手机的ECG设备在家中获得VRR测量数据。根据这些数据,概述了三种方案:(A)三次每小时8次的抽查,(B)三次每小时6次的抽查,(C)五次预定的抽查。采用中观、平均和中位VRR与aECG进行比较。利用余弦分析探讨了昼夜节律变化的存在。结果:共分析18例aecg,其中14例用于检验抽查方案。方案与aECG表现出中度至强相关性,其中方案B表现最佳(平均,r = 0.84, P=140 bpm)。在18只狗中有17只(94%)发现了VRR的昼夜变化。局限性:本研究受限于人群少、高度普遍的VRR不足、非标准化治疗、测量伪影和与aECG精确的时间对齐。结论:抽查方案为房颤犬的VRR评估提供了一种实用、经济的替代方案。我们已经确定,方案中的平均VRR >140 bpm预示着aECG的心率控制不足。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Veterinary Cardiology
Journal of Veterinary Cardiology VETERINARY SCIENCES-
CiteScore
2.50
自引率
25.00%
发文量
66
审稿时长
154 days
期刊介绍: The mission of the Journal of Veterinary Cardiology is to publish peer-reviewed reports of the highest quality that promote greater understanding of cardiovascular disease, and enhance the health and well being of animals and humans. The Journal of Veterinary Cardiology publishes original contributions involving research and clinical practice that include prospective and retrospective studies, clinical trials, epidemiology, observational studies, and advances in applied and basic research. The Journal invites submission of original manuscripts. Specific content areas of interest include heart failure, arrhythmias, congenital heart disease, cardiovascular medicine, surgery, hypertension, health outcomes research, diagnostic imaging, interventional techniques, genetics, molecular cardiology, and cardiovascular pathology, pharmacology, and toxicology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书