Anh Nguyen, Andrew Civitello, Alexis Shafii, Gabriel Loor, Subhasis Chatterjee, O Howard Frazier, Kenneth Liao
{"title":"Evolution of Gastrointestinal Bleeding in Patients Supported With Continuous-Flow Left Ventricular Assist Devices.","authors":"Anh Nguyen, Andrew Civitello, Alexis Shafii, Gabriel Loor, Subhasis Chatterjee, O Howard Frazier, Kenneth Liao","doi":"10.1097/MAT.0000000000002597","DOIUrl":null,"url":null,"abstract":"<p><p>We assessed characteristics and risk factors of gastrointestinal (GI) bleeding in patients with continuous-flow left ventricular assist devices (CF-LVAD) in our institutional Intermacs database (2008-2023). Patient characteristics were reported as frequencies/proportions for categorical variables and as median/interquartile range (IQR) for continuous variables. Multivariable Cox proportional hazards regression identified GI bleeding risk factors. Among 1,030 CF-LVADs implanted, the median age was 58.5 years (IQR: 50.4-65.4), and 79.4% were male. Pre-implant Intermacs profile less than or equal to 3 was seen in 80.6%. Axial-flow LVADs were used in 55.2%, partially magnetically levitated centrifugal-flow in 30.7%, and fully magnetically levitated centrifugal-flow in 14.1%. GI bleeding occurred in 37.5% (13.9 per 100 person-years), with 65.3% rebleeding. Bleeding sources: 54.4% upper GI, 21.8% lower GI, and 23.8% unknown. The median time from LVAD implant to first GI bleeding was 5 months (IQR: 1-19); to any GI bleeding was 11 months (IQR: 2-31). Patients older than 50 years were three times more likely to develop GI bleeding (hazard ratio [HR]: 3.15, p < 0.001). Fully magnetically levitated centrifugal-flow LVADs reduced GI bleeding risk by four times compared to axial-flow LVADs (HR: 0.26, p < 0.001). Coronary artery disease (HR: 1.49, p = 0.022) and chronic kidney disease (HR: 1.91, p = 0.001) nearly double the risk of GI bleeding.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":"e222-e227"},"PeriodicalIF":2.2000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002597","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
We assessed characteristics and risk factors of gastrointestinal (GI) bleeding in patients with continuous-flow left ventricular assist devices (CF-LVAD) in our institutional Intermacs database (2008-2023). Patient characteristics were reported as frequencies/proportions for categorical variables and as median/interquartile range (IQR) for continuous variables. Multivariable Cox proportional hazards regression identified GI bleeding risk factors. Among 1,030 CF-LVADs implanted, the median age was 58.5 years (IQR: 50.4-65.4), and 79.4% were male. Pre-implant Intermacs profile less than or equal to 3 was seen in 80.6%. Axial-flow LVADs were used in 55.2%, partially magnetically levitated centrifugal-flow in 30.7%, and fully magnetically levitated centrifugal-flow in 14.1%. GI bleeding occurred in 37.5% (13.9 per 100 person-years), with 65.3% rebleeding. Bleeding sources: 54.4% upper GI, 21.8% lower GI, and 23.8% unknown. The median time from LVAD implant to first GI bleeding was 5 months (IQR: 1-19); to any GI bleeding was 11 months (IQR: 2-31). Patients older than 50 years were three times more likely to develop GI bleeding (hazard ratio [HR]: 3.15, p < 0.001). Fully magnetically levitated centrifugal-flow LVADs reduced GI bleeding risk by four times compared to axial-flow LVADs (HR: 0.26, p < 0.001). Coronary artery disease (HR: 1.49, p = 0.022) and chronic kidney disease (HR: 1.91, p = 0.001) nearly double the risk of GI bleeding.
期刊介绍:
ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world.
The official publication of the American Society for Artificial Internal Organs.