Robotic Compounding for Whole-Brain Non-Invasive 3D Ultrasound Localization Microscopy

IF 1.8
Hatim Belgharbi;Francisco Santibanez;Paul A. Dayton;Gianmarco F. Pinton
{"title":"Robotic Compounding for Whole-Brain Non-Invasive 3D Ultrasound Localization Microscopy","authors":"Hatim Belgharbi;Francisco Santibanez;Paul A. Dayton;Gianmarco F. Pinton","doi":"10.1109/OJUFFC.2025.3617425","DOIUrl":null,"url":null,"abstract":"3D ultrasound localization microscopy (ULM) allows the extraction of anatomical and functional representations of vascular networks with a spatial resolution beyond the diffraction limit (<inline-formula> <tex-math>$\\sim \\lambda $ </tex-math></inline-formula>/10) by localizing injected microbubble (MB) contrast agents and tracking their positions over time. To advance this technology towards clinical diagnostics, the ability to obtain a large field of view (FOV) becomes a pressing necessity. One solution for large FOV imaging is automated stitching/compounding of multiple volume acquisitions. This is challenging for full-brain imaging, as the acquisition of images through the skull requires parallel positioning of the transducer surface relative to the skull to optimize ultrasound transmission. Herein, we demonstrate an automated positioning system that relies on predefined optimized orientations, enabling fast acquisition and positioning for rapid full-brain imaging. As an example of expanded FOV application, we achieved non-invasive full-brain imaging of an 8-week-old rat by collecting data across 11 transducer positions. To ensure optimal acoustic penetration through the intact skull, the transducer orientation was robotically positioned. We compared this approach with pure transducer translation. Additionally, we acquired whole-brain vasculature images from 4-week-old rats using 24 100-second scans of optimized transducer positions, comparing these results to a single-position 2400-second scan. Automated robotic compounding enabled the acquisition of full-brain vascular information while minimizing acquisition dead time. Optimized transducer angles enhanced the vascular network visualization across the brain, including challenging areas such as the cerebellum (10x improvement) and hindbrain (3.5x improvement). Moreover, our multi-position acquisition method allowed us to capture approximately four times more vascular volume transcranially, covering the entire rat brain, compared to the ~1 cm3 typically obtained with single-position acquisitions using the same transducer. This work demonstrates the benefit of automated robot-assisted multi-angle/multi-position acquisitions in ULM to acquire a volumetric field of view larger than otherwise possible with a single position acquisition, especially those through the skull.","PeriodicalId":73301,"journal":{"name":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","volume":"5 ","pages":"204-213"},"PeriodicalIF":1.8000,"publicationDate":"2025-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11192505","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11192505/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

3D ultrasound localization microscopy (ULM) allows the extraction of anatomical and functional representations of vascular networks with a spatial resolution beyond the diffraction limit ( $\sim \lambda $ /10) by localizing injected microbubble (MB) contrast agents and tracking their positions over time. To advance this technology towards clinical diagnostics, the ability to obtain a large field of view (FOV) becomes a pressing necessity. One solution for large FOV imaging is automated stitching/compounding of multiple volume acquisitions. This is challenging for full-brain imaging, as the acquisition of images through the skull requires parallel positioning of the transducer surface relative to the skull to optimize ultrasound transmission. Herein, we demonstrate an automated positioning system that relies on predefined optimized orientations, enabling fast acquisition and positioning for rapid full-brain imaging. As an example of expanded FOV application, we achieved non-invasive full-brain imaging of an 8-week-old rat by collecting data across 11 transducer positions. To ensure optimal acoustic penetration through the intact skull, the transducer orientation was robotically positioned. We compared this approach with pure transducer translation. Additionally, we acquired whole-brain vasculature images from 4-week-old rats using 24 100-second scans of optimized transducer positions, comparing these results to a single-position 2400-second scan. Automated robotic compounding enabled the acquisition of full-brain vascular information while minimizing acquisition dead time. Optimized transducer angles enhanced the vascular network visualization across the brain, including challenging areas such as the cerebellum (10x improvement) and hindbrain (3.5x improvement). Moreover, our multi-position acquisition method allowed us to capture approximately four times more vascular volume transcranially, covering the entire rat brain, compared to the ~1 cm3 typically obtained with single-position acquisitions using the same transducer. This work demonstrates the benefit of automated robot-assisted multi-angle/multi-position acquisitions in ULM to acquire a volumetric field of view larger than otherwise possible with a single position acquisition, especially those through the skull.
全脑无创三维超声定位显微镜的机器人复合
3D超声定位显微镜(ULM)可以通过定位注入的微泡(MB)造影剂并随时间跟踪其位置,以超过衍射极限的空间分辨率($\sim \lambda $ /10)提取血管网络的解剖和功能表征。为了将这项技术推向临床诊断,获得大视场(FOV)的能力成为迫切需要。大视场成像的一个解决方案是自动拼接/复合多个体积采集。这对于全脑成像来说是一个挑战,因为通过颅骨获取图像需要将换能器表面相对于颅骨平行定位,以优化超声传输。在此,我们展示了一个自动定位系统,该系统依赖于预定义的优化方向,能够快速获取和定位快速全脑成像。作为扩展视场应用的一个例子,我们通过收集11个换能器位置的数据,实现了一只8周大鼠的非侵入性全脑成像。为了确保最佳的声音穿透完整的颅骨,换能器的方向是机器人定位的。我们将这种方法与纯换能器翻译进行了比较。此外,我们通过24次100秒的优化换能器位置扫描获得了4周龄大鼠的全脑血管图像,并将这些结果与单次2400秒的扫描结果进行了比较。自动化的机器人合成使全脑血管信息的采集成为可能,同时最大限度地减少采集死时间。优化的换能器角度增强了整个大脑的血管网络可视化,包括小脑(改善10倍)和后脑(改善3.5倍)等具有挑战性的区域。此外,我们的多位置采集方法使我们能够捕获大约四倍多的血管体积,覆盖整个大鼠脑,而使用相同换能器的单位置采集通常获得1 cm3。这项工作证明了在ULM中,自动化机器人辅助的多角度/多位置采集的好处,它可以获得比单一位置采集更大的体积视野,特别是通过头骨的位置采集。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书