Evaluating intra-fraction motion and its dosimetric impact in ethos online adaptive radiotherapy for prostate cancer.

IF 3.6 Q4 Medicine
Precision Radiation Oncology Pub Date : 2025-08-20 eCollection Date: 2025-09-01 DOI:10.1002/pro6.70013
Yoganathan Sa, Ahamed Basith, Rajeev Choudary Apsani, Venkada Manickam Gurusamy, Amine Khemissi, Satheesh Paloor, Saju Divakar, Sarah McCabe, Rabih Hammoud, Noora Al-Hammadi
{"title":"Evaluating intra-fraction motion and its dosimetric impact in ethos online adaptive radiotherapy for prostate cancer.","authors":"Yoganathan Sa, Ahamed Basith, Rajeev Choudary Apsani, Venkada Manickam Gurusamy, Amine Khemissi, Satheesh Paloor, Saju Divakar, Sarah McCabe, Rabih Hammoud, Noora Al-Hammadi","doi":"10.1002/pro6.70013","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluated the geometric and dosimetric uncertainties during online adaptive radiotherapy (ART) for prostate cancer.</p><p><strong>Methods: </strong>Sequential cone beam computed tomography (CBCT) scans from 52 sessions involving 13 patients were analyzed. An ART plan was generated using CBCT1, followed by a verification scan (CBCT2) acquired 13.1 ± 3.0 minutes before treatment delivery. New contours (prostate, seminal vesicles, bladder, rectum, and bowel) were delineated on CBCT2 and transferred to CBCT1 for dose distribution analysis. Three dimensional contour variations were quantified, new planning target volume (PTV) margins were calculated, and their dosimetric benefits were assessed.</p><p><strong>Results: </strong>No significant differences were observed in the high-dose volumes (V60 Gy and V57 Gy) of the bladder and rectum (<i>P</i> > 0.05). PTV margins were 2.6 mm, 2.4 mm, and 2.6 mm in the lateral, vertical, and longitudinal directions for the prostate, and 3.9 mm, 3.8 mm, and 4.3 mm for the seminal vesicles, respectively. These margin reductions led to a 37% reduction in the dose to the surrounding critical organs, while maintaining consistent target coverage.</p><p><strong>Conclusion: </strong>This study supports symmetric PTV margins of 3 mm for the prostate and 4.5 mm for the seminal vesicles in online ART, thereby contributing to the development of optimized treatment strategies for prostate cancer.</p>","PeriodicalId":32406,"journal":{"name":"Precision Radiation Oncology","volume":"9 3","pages":"202-209"},"PeriodicalIF":3.6000,"publicationDate":"2025-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12559917/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Precision Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/pro6.70013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study evaluated the geometric and dosimetric uncertainties during online adaptive radiotherapy (ART) for prostate cancer.

Methods: Sequential cone beam computed tomography (CBCT) scans from 52 sessions involving 13 patients were analyzed. An ART plan was generated using CBCT1, followed by a verification scan (CBCT2) acquired 13.1 ± 3.0 minutes before treatment delivery. New contours (prostate, seminal vesicles, bladder, rectum, and bowel) were delineated on CBCT2 and transferred to CBCT1 for dose distribution analysis. Three dimensional contour variations were quantified, new planning target volume (PTV) margins were calculated, and their dosimetric benefits were assessed.

Results: No significant differences were observed in the high-dose volumes (V60 Gy and V57 Gy) of the bladder and rectum (P > 0.05). PTV margins were 2.6 mm, 2.4 mm, and 2.6 mm in the lateral, vertical, and longitudinal directions for the prostate, and 3.9 mm, 3.8 mm, and 4.3 mm for the seminal vesicles, respectively. These margin reductions led to a 37% reduction in the dose to the surrounding critical organs, while maintaining consistent target coverage.

Conclusion: This study supports symmetric PTV margins of 3 mm for the prostate and 4.5 mm for the seminal vesicles in online ART, thereby contributing to the development of optimized treatment strategies for prostate cancer.

Abstract Image

Abstract Image

Abstract Image

评价分数内运动及其在ethos在线适应放射治疗前列腺癌中的剂量学影响。
目的:本研究评估前列腺癌在线适应性放疗(ART)的几何和剂量学不确定性。方法:对13例患者的52次连续锥形束计算机断层扫描(CBCT)进行分析。使用CBCT1生成ART计划,然后在治疗交付前13.1±3.0分钟进行验证扫描(CBCT2)。在CBCT2上描绘新的轮廓(前列腺、精囊、膀胱、直肠和肠道),并将其转移到CBCT1上进行剂量分布分析。对三维轮廓变化进行量化,计算新的规划靶体积(PTV)边际,并评估其剂量学效益。结果:大鼠膀胱和直肠高剂量容积(V60 Gy和V57 Gy)差异无统计学意义(P < 0.05)。前列腺PTV侧缘、纵缘和纵缘分别为2.6 mm、2.4 mm和2.6 mm,精囊PTV侧缘分别为3.9 mm、3.8 mm和4.3 mm。这些边际减少导致周围关键器官的剂量减少37%,同时保持一致的目标覆盖。结论:本研究支持在线ART中前列腺对称PTV边缘为3mm,精囊对称PTV边缘为4.5 mm,从而为前列腺癌优化治疗策略的制定做出贡献。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Precision Radiation Oncology
Precision Radiation Oncology Medicine-Oncology
CiteScore
1.20
自引率
0.00%
发文量
32
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书