Michael Discher , Céline Bassinet , Hyoungtaek Kim
{"title":"Evaluating SMD resistors in electronic devices as accident dosimeters using red thermoluminescence","authors":"Michael Discher , Céline Bassinet , Hyoungtaek Kim","doi":"10.1016/j.radmeas.2025.107548","DOIUrl":null,"url":null,"abstract":"<div><div>Traditional protocols utilizing optically stimulated luminescence (OSL) and thermoluminescence (TL) of surface-mounted devices (SMDs) for retrospective dosimetry have demonstrated promising results, but limitations in sensitivity, especially for a limited number of SMD components, and small sample sizes, have prompted the exploration of alternative methods. The red thermoluminescence (RTL) protocol has emerged as a promising alternative, taking advantage of the strong TL emission of SMD components in the near-infrared spectral range.</div><div>The present study investigates the dosimetric performance of red thermoluminescence (TL) emission from surface-mounted devices (SMDs) and its potential for use in accident dosimetry. Key characteristics, such as intrinsic zero-dose signal, signal reproducibility, dose-response relationship, signal stability, and a dose recovery test, were systematically analysed. An irradiation experiment was conducted in which SMDs were exposed to 6 MV X-rays using LINAC, and subsequent dose reconstruction was carried out employing the RTL protocol. The experiments demonstrated that a new RTL protocol yields promising signal intensities, and successful dose reconstruction was achieved even after delayed readout, with fading corrections applied. Dose estimates obtained from single SMD resistors, both reference components and those extracted from a smartwatch, showed good agreement with reference dosimeters, with overestimations between 5 % and 24 %. These findings confirm that the RTL method includes sufficient sensitivity and the ability to analyse very limited sample quantities, particularly in scenarios where signal sensitivity is critical.</div></div>","PeriodicalId":21055,"journal":{"name":"Radiation Measurements","volume":"190 ","pages":"Article 107548"},"PeriodicalIF":1.8000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Measurements","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350448725001775","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/27 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Traditional protocols utilizing optically stimulated luminescence (OSL) and thermoluminescence (TL) of surface-mounted devices (SMDs) for retrospective dosimetry have demonstrated promising results, but limitations in sensitivity, especially for a limited number of SMD components, and small sample sizes, have prompted the exploration of alternative methods. The red thermoluminescence (RTL) protocol has emerged as a promising alternative, taking advantage of the strong TL emission of SMD components in the near-infrared spectral range.
The present study investigates the dosimetric performance of red thermoluminescence (TL) emission from surface-mounted devices (SMDs) and its potential for use in accident dosimetry. Key characteristics, such as intrinsic zero-dose signal, signal reproducibility, dose-response relationship, signal stability, and a dose recovery test, were systematically analysed. An irradiation experiment was conducted in which SMDs were exposed to 6 MV X-rays using LINAC, and subsequent dose reconstruction was carried out employing the RTL protocol. The experiments demonstrated that a new RTL protocol yields promising signal intensities, and successful dose reconstruction was achieved even after delayed readout, with fading corrections applied. Dose estimates obtained from single SMD resistors, both reference components and those extracted from a smartwatch, showed good agreement with reference dosimeters, with overestimations between 5 % and 24 %. These findings confirm that the RTL method includes sufficient sensitivity and the ability to analyse very limited sample quantities, particularly in scenarios where signal sensitivity is critical.
期刊介绍:
The journal seeks to publish papers that present advances in the following areas: spontaneous and stimulated luminescence (including scintillating materials, thermoluminescence, and optically stimulated luminescence); electron spin resonance of natural and synthetic materials; the physics, design and performance of radiation measurements (including computational modelling such as electronic transport simulations); the novel basic aspects of radiation measurement in medical physics. Studies of energy-transfer phenomena, track physics and microdosimetry are also of interest to the journal.
Applications relevant to the journal, particularly where they present novel detection techniques, novel analytical approaches or novel materials, include: personal dosimetry (including dosimetric quantities, active/electronic and passive monitoring techniques for photon, neutron and charged-particle exposures); environmental dosimetry (including methodological advances and predictive models related to radon, but generally excluding local survey results of radon where the main aim is to establish the radiation risk to populations); cosmic and high-energy radiation measurements (including dosimetry, space radiation effects, and single event upsets); dosimetry-based archaeological and Quaternary dating; dosimetry-based approaches to thermochronometry; accident and retrospective dosimetry (including activation detectors), and dosimetry and measurements related to medical applications.