Evaluation of the Radiopacity, pH, and Calcium Ion Release of Calcium Silicate and Epoxy Resin-based Endodontic Cements.

Q3 Dentistry
Iranian Endodontic Journal Pub Date : 2025-01-01 Epub Date: 2025-10-14 DOI:10.22037/iej.v20i1.48935
Milagros Judith Loyola-Cano, Carmen Rosa García-Rupaya
{"title":"Evaluation of the Radiopacity, pH, and Calcium Ion Release of Calcium Silicate and Epoxy Resin-based Endodontic Cements.","authors":"Milagros Judith Loyola-Cano, Carmen Rosa García-Rupaya","doi":"10.22037/iej.v20i1.48935","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Endodontic cements are essential materials for achieving successful root canal treatment. Therefore, they must present adequate physicochemical properties to ensure optimal clinical performance. This study aimed to evaluate radiopacity, pH, and calcium ion release of calcium silicate- and epoxy resin-based cements/sealers.</p><p><strong>Materials and methods: </strong>Four materials were evaluated: Vioseal, AH-Plus, AH-Plus Bioceramic Sealer, and MTA Angelus. Ten cylindrical specimens (10 mm diameter, 1 mm height) per group were prepared for each tested property, totaling 80 samples. The same specimens were used for pH and calcium ion release, while separate specimens were used for radiopacity. All samples were stored at 37<sup>°</sup>C and 95% humidity. Radiopacity was assessed by digital radiography using an aluminum step wedge (1-10 mm). pH was measured at 1, 7, and 14 days using a calibrated digital pH meter. Calcium ion release was determined using atomic absorption spectrophotometry. Data were analyzed using Kruskal-Wallis and Dwass-Steel-Critchlow-Fligner post hoc tests (<i>P</i><0.05).</p><p><strong>Results: </strong>Vioseal and AH-Plus showed the highest radiopacity values (9.98±0.42 mm Al and 10.00±0.38 mm Al, respectively), while AH-Plus Bioceramic Sealer (9.04±0.28 mm Al) and MTA Angelus (4.72±0.40 mm Al) showed lower values. Regarding pH, AH-Plus Bioceramic presented the highest and most sustained alkaline value (up to 12.5), and AH-Plus the lowest (6.25±0.26). In calcium ion release, Vioseal showed the highest release on day 7 (29.4±3.12 ppm), while AH-Plus Bioceramic Sealer also peaked on day 7 (18.60±5.54 ppm); MTA Angelus presented its highest release on day 1 (11.80±1.00 ppm).</p><p><strong>Conclusion: </strong>All evaluated cements/sealers met the ISO 6876 standard for radiopacity. Calcium silicate-based cements showed an alkaline pH and sustained calcium ion release, whereas Vioseal presented an initially high and transient release.</p>","PeriodicalId":14534,"journal":{"name":"Iranian Endodontic Journal","volume":"20 1","pages":"e40"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12554232/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Endodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22037/iej.v20i1.48935","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Endodontic cements are essential materials for achieving successful root canal treatment. Therefore, they must present adequate physicochemical properties to ensure optimal clinical performance. This study aimed to evaluate radiopacity, pH, and calcium ion release of calcium silicate- and epoxy resin-based cements/sealers.

Materials and methods: Four materials were evaluated: Vioseal, AH-Plus, AH-Plus Bioceramic Sealer, and MTA Angelus. Ten cylindrical specimens (10 mm diameter, 1 mm height) per group were prepared for each tested property, totaling 80 samples. The same specimens were used for pH and calcium ion release, while separate specimens were used for radiopacity. All samples were stored at 37°C and 95% humidity. Radiopacity was assessed by digital radiography using an aluminum step wedge (1-10 mm). pH was measured at 1, 7, and 14 days using a calibrated digital pH meter. Calcium ion release was determined using atomic absorption spectrophotometry. Data were analyzed using Kruskal-Wallis and Dwass-Steel-Critchlow-Fligner post hoc tests (P<0.05).

Results: Vioseal and AH-Plus showed the highest radiopacity values (9.98±0.42 mm Al and 10.00±0.38 mm Al, respectively), while AH-Plus Bioceramic Sealer (9.04±0.28 mm Al) and MTA Angelus (4.72±0.40 mm Al) showed lower values. Regarding pH, AH-Plus Bioceramic presented the highest and most sustained alkaline value (up to 12.5), and AH-Plus the lowest (6.25±0.26). In calcium ion release, Vioseal showed the highest release on day 7 (29.4±3.12 ppm), while AH-Plus Bioceramic Sealer also peaked on day 7 (18.60±5.54 ppm); MTA Angelus presented its highest release on day 1 (11.80±1.00 ppm).

Conclusion: All evaluated cements/sealers met the ISO 6876 standard for radiopacity. Calcium silicate-based cements showed an alkaline pH and sustained calcium ion release, whereas Vioseal presented an initially high and transient release.

Abstract Image

Abstract Image

Abstract Image

硅酸钙和环氧树脂基根管胶结物的透光度、pH值和钙离子释放的评价。
根管胶合剂是根管治疗成功的重要材料。因此,它们必须具有足够的物理化学性质,以确保最佳的临床性能。本研究旨在评估硅酸钙和环氧树脂基水泥/密封剂的透光性、pH值和钙离子释放。材料与方法:采用Vioseal、AH-Plus、AH-Plus生物陶瓷密封剂和MTA Angelus四种材料进行评价。每组制备10个圆柱形试样(直径10 mm,高1 mm),共80个试样。pH值和钙离子释放量采用同一标本,放射线透明度采用不同标本。所有样品在37°C和95%湿度下保存。采用铝制阶梯楔形片(1-10 mm)进行数字x线摄影评估放射不透明度。在第1、7和14天使用校准的数字pH计测量pH值。用原子吸收分光光度法测定钙离子释放量。采用Kruskal-Wallis和dwas -钢- critchlow - fligner事后检验对数据进行分析(结果:Vioseal和AH-Plus的放射不透明度值最高,分别为9.98±0.42 mm Al和10.00±0.38 mm Al), AH-Plus生物陶瓷Sealer(9.04±0.28 mm Al)和MTA Angelus(4.72±0.40 mm Al)的放射不透明度值较低。就pH值而言,AH-Plus生物陶瓷的碱性值最高且最持久(可达12.5),AH-Plus最低(6.25±0.26)。在钙离子释放方面,Vioseal在第7天释放最高(29.4±3.12 ppm), AH-Plus生物陶瓷Sealer在第7天也达到峰值(18.60±5.54 ppm);MTA Angelus在第1天释放量最高(11.80±1.00 ppm)。结论:所有评估的骨水泥/密封剂均符合ISO 6876标准。硅酸钙基水泥具有碱性和持续的钙离子释放,而Vioseal则具有初始高且短暂的释放。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Iranian Endodontic Journal
Iranian Endodontic Journal Dentistry-Dentistry (all)
CiteScore
1.30
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊介绍: The Iranian Endodontic Journal (IEJ) is an international peer-reviewed biomedical publication, the aim of which is to provide a scientific medium of communication for researchers throughout the globe. IEJ aims to publish the highest quality articles, both clinical and scientific, on all aspects of Endodontics. The journal is an official Journal of the Iranian Center for Endodontic Research (ICER) and the Iranian Association of Endodontists (IAE). The Journal welcomes articles related to the scientific or applied aspects of endodontics e.g. original researches, systematic reviews, meta-analyses, review articles, clinical trials, case series/reports, hypotheses, letters to the editor, etc. From the beginning (i.e. since 2006), the IEJ was the first open access endodontic journal in the world, which gave readers free and instant access to published articles and enabling them faster discovery of the latest endodontic research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书