CXCL10 (IP-10) and anti-ZnT8 autoantibodies: Exploratory indicators of risk in pancreatic transplant rejection.

IF 1.9 Q2 MEDICINE, RESEARCH & EXPERIMENTAL
Biomarker Insights Pub Date : 2025-10-18 eCollection Date: 2025-01-01 DOI:10.1177/11772719251381963
Mikk Jäätma, Marko Murruste, Karri Kase, Kaja Metsküla, Raivo Uibo, Tamara Vorobjova
{"title":"CXCL10 (IP-10) and anti-ZnT8 autoantibodies: Exploratory indicators of risk in pancreatic transplant rejection.","authors":"Mikk Jäätma, Marko Murruste, Karri Kase, Kaja Metsküla, Raivo Uibo, Tamara Vorobjova","doi":"10.1177/11772719251381963","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Measurement of chemokine CXCL10 is a novel approach to assess the transplant rejection risk and to detect the rejection. While CXCL10 has shown itself to be useful in renal transplants, there are only a few studies on the association between pancreas transplantation and CXCL10. Furthermore, the importance of autoantibodies associated with type I diabetes in pancreas transplantation are relatively poorly understood.</p><p><strong>Objectives: </strong>To determine whether there is an association between CXCL10 plasma levels and graft rejection in simultaneous pancreas and kidney transplant recipients, and to assess the effects of pancreas autoantibodies on pancreatic transplant rejection.</p><p><strong>Design: </strong>A retrospective case-control study was conducted.</p><p><strong>Methods: </strong>In total of 23 individuals (11 male and 12 female, mean age 39.5 (SD ± 7.6) years) who underwent simultaneous pancreas and kidney transplantation, and in 8 healthy controls (evenly distributed in terms of gender, mean age 26.1 (SD ± 1.5) years) plasma samples were analyzed for CXCL10 and autoantibody levels using ELISA. The data was categorized into preoperative, perioperative and postoperative samples and were further juxtaposed in relation to rejection episodes.</p><p><strong>Results: </strong>Preoperative CXCL10 levels did not differ from those for healthy individuals, but they rose postoperatively (<i>P</i> = .02). The median preoperative plasma concentration of CXCL10 was 68 pg/ml and increased to 123 pg/ml postoperatively. A postoperative plasma CXCL10 cut-off value of 297 pg/ml was indicative of rejection. Postoperative autoantibodies were detected in 10 recipients, 4 of whom were positive for anti-ZnT8 autoantibodies, and 2 were positive for more than 1 type autoantibody. All recipients who were positive for anti-ZnT8 autoantibodies or for more than 1 type autoantibody experienced rejection.</p><p><strong>Conclusion: </strong>Elevated CXCL10 levels during the first 3 months after transplantation seem to be a risk factor for rejection. The post transplant presence of anti-ZnT8 autoantibodies was associated with transplant rejection.</p>","PeriodicalId":47060,"journal":{"name":"Biomarker Insights","volume":"20 ","pages":"11772719251381963"},"PeriodicalIF":1.9000,"publicationDate":"2025-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12541173/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomarker Insights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/11772719251381963","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Measurement of chemokine CXCL10 is a novel approach to assess the transplant rejection risk and to detect the rejection. While CXCL10 has shown itself to be useful in renal transplants, there are only a few studies on the association between pancreas transplantation and CXCL10. Furthermore, the importance of autoantibodies associated with type I diabetes in pancreas transplantation are relatively poorly understood.

Objectives: To determine whether there is an association between CXCL10 plasma levels and graft rejection in simultaneous pancreas and kidney transplant recipients, and to assess the effects of pancreas autoantibodies on pancreatic transplant rejection.

Design: A retrospective case-control study was conducted.

Methods: In total of 23 individuals (11 male and 12 female, mean age 39.5 (SD ± 7.6) years) who underwent simultaneous pancreas and kidney transplantation, and in 8 healthy controls (evenly distributed in terms of gender, mean age 26.1 (SD ± 1.5) years) plasma samples were analyzed for CXCL10 and autoantibody levels using ELISA. The data was categorized into preoperative, perioperative and postoperative samples and were further juxtaposed in relation to rejection episodes.

Results: Preoperative CXCL10 levels did not differ from those for healthy individuals, but they rose postoperatively (P = .02). The median preoperative plasma concentration of CXCL10 was 68 pg/ml and increased to 123 pg/ml postoperatively. A postoperative plasma CXCL10 cut-off value of 297 pg/ml was indicative of rejection. Postoperative autoantibodies were detected in 10 recipients, 4 of whom were positive for anti-ZnT8 autoantibodies, and 2 were positive for more than 1 type autoantibody. All recipients who were positive for anti-ZnT8 autoantibodies or for more than 1 type autoantibody experienced rejection.

Conclusion: Elevated CXCL10 levels during the first 3 months after transplantation seem to be a risk factor for rejection. The post transplant presence of anti-ZnT8 autoantibodies was associated with transplant rejection.

Abstract Image

Abstract Image

Abstract Image

CXCL10 (IP-10)和抗znt8自身抗体:胰腺移植排斥风险的探索性指标
背景:趋化因子CXCL10的测定是评估移植排斥风险和检测排斥反应的一种新方法。虽然CXCL10已被证明在肾移植中有用,但关于胰腺移植与CXCL10之间关系的研究却很少。此外,与1型糖尿病相关的自身抗体在胰腺移植中的重要性还相对缺乏了解。目的:探讨胰肾同时移植患者血浆CXCL10水平与移植排斥反应之间是否存在相关性,并评估胰腺自身抗体对胰腺移植排斥反应的影响。设计:采用回顾性病例对照研究。方法:对23例同时行胰肾移植患者(男性11例,女性12例,平均年龄39.5 (SD±7.6)岁)和8例健康对照(性别均匀分布,平均年龄26.1 (SD±1.5)岁)的血浆样本进行ELISA检测CXCL10和自身抗体水平。数据分为术前、围手术期和术后样本,并进一步与排斥事件并置。结果:术前CXCL10水平与健康人无差异,但术后CXCL10水平升高(P = 0.02)。术前CXCL10的中位血药浓度为68 pg/ml,术后升高至123 pg/ml。术后血浆CXCL10临界值297 pg/ml提示排斥反应。术后10例患者检测自身抗体,其中抗znt8自身抗体阳性4例,1型以上自身抗体阳性2例。所有抗znt8自身抗体阳性或1种以上自身抗体阳性的受体均发生排斥反应。结论:移植后3个月内CXCL10水平升高可能是排斥反应的危险因素。移植后抗znt8自身抗体的存在与移植排斥有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomarker Insights
Biomarker Insights MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
6.00
自引率
0.00%
发文量
26
审稿时长
8 weeks
期刊介绍: An open access, peer reviewed electronic journal that covers all aspects of biomarker research and clinical applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书