Evaluating the Clinical Validity of Commercially Available Virtual Reality Headsets for Visual Field Testing: A Systematic Review.

IF 1.8 Q2 Medicine
Jesús Vera, Alan N Glazier, Mark T Dunbar, Douglas Ripkin, Masoud Nafey
{"title":"Evaluating the Clinical Validity of Commercially Available Virtual Reality Headsets for Visual Field Testing: A Systematic Review.","authors":"Jesús Vera, Alan N Glazier, Mark T Dunbar, Douglas Ripkin, Masoud Nafey","doi":"10.3390/vision9040080","DOIUrl":null,"url":null,"abstract":"<p><p>Virtual reality (VR) technology has emerged as a promising alternative to conventional perimetry for assessing visual fields. However, the clinical validity of commercially available VR-based perimetry devices remains uncertain due to variability in hardware, software, and testing protocols. A systematic review was conducted following PRISMA guidelines to evaluate the validity of VR-based perimetry compared to the Humphrey Field Analyzer (HFA). Literature searches were performed across MEDLINE, Embase, Scopus, and Web of Science. Studies were included if they assessed commercially available VR-based visual field devices in comparison to HFA and reported visual field outcomes. Devices were categorized by regulatory status (FDA, CE, or uncertified), and results were synthesized narratively. Nineteen studies were included. Devices such as Heru, Olleyes VisuALL, and the Advanced Vision Analyzer showed promising agreement with HFA metrics, especially in moderate to advanced glaucoma. However, variability in performance was observed depending on disease severity, population type, and device specifications. Limited dynamic range and lack of eye tracking were common limitations in lower-complexity devices. Pediatric validation and performance in early-stage disease were often suboptimal. Several VR-based perimetry systems demonstrate clinically acceptable validity compared to HFA, particularly in certain patient subgroups. However, broader validation, protocol standardization, and regulatory approval are essential for widespread clinical adoption. These devices may support more accessible visual field testing through telemedicine and decentralized care.</p>","PeriodicalId":36586,"journal":{"name":"Vision (Switzerland)","volume":"9 4","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12551044/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vision (Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/vision9040080","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Virtual reality (VR) technology has emerged as a promising alternative to conventional perimetry for assessing visual fields. However, the clinical validity of commercially available VR-based perimetry devices remains uncertain due to variability in hardware, software, and testing protocols. A systematic review was conducted following PRISMA guidelines to evaluate the validity of VR-based perimetry compared to the Humphrey Field Analyzer (HFA). Literature searches were performed across MEDLINE, Embase, Scopus, and Web of Science. Studies were included if they assessed commercially available VR-based visual field devices in comparison to HFA and reported visual field outcomes. Devices were categorized by regulatory status (FDA, CE, or uncertified), and results were synthesized narratively. Nineteen studies were included. Devices such as Heru, Olleyes VisuALL, and the Advanced Vision Analyzer showed promising agreement with HFA metrics, especially in moderate to advanced glaucoma. However, variability in performance was observed depending on disease severity, population type, and device specifications. Limited dynamic range and lack of eye tracking were common limitations in lower-complexity devices. Pediatric validation and performance in early-stage disease were often suboptimal. Several VR-based perimetry systems demonstrate clinically acceptable validity compared to HFA, particularly in certain patient subgroups. However, broader validation, protocol standardization, and regulatory approval are essential for widespread clinical adoption. These devices may support more accessible visual field testing through telemedicine and decentralized care.

Abstract Image

评估商用虚拟现实头显的临床有效性,用于视野测试:系统回顾。
虚拟现实(VR)技术已经成为一种有前途的替代传统的视野测量技术。然而,由于硬件、软件和测试方案的差异,商用vr周边测量设备的临床有效性仍然不确定。根据PRISMA指南进行系统评价,与Humphrey Field Analyzer (HFA)相比,评估基于vr的视野测量的有效性。通过MEDLINE、Embase、Scopus和Web of Science进行文献检索。如果研究评估了市售的基于vr的视野设备与HFA的比较,并报告了视野结果,则纳入研究。器械按监管状态(FDA、CE或未认证)进行分类,并对结果进行叙述性综合。纳入了19项研究。Heru、Olleyes VisuALL和Advanced Vision Analyzer等设备显示出与HFA指标的良好一致性,特别是在中晚期青光眼中。然而,根据疾病严重程度、人群类型和设备规格,观察到性能的差异。有限的动态范围和缺乏眼动追踪是低复杂度设备的常见限制。儿童早期疾病的验证和表现往往不理想。与HFA相比,一些基于vr的视野测量系统显示出临床可接受的有效性,特别是在某些患者亚组中。然而,更广泛的验证、方案标准化和监管批准对于广泛的临床应用至关重要。这些设备可以通过远程医疗和分散护理支持更容易获得的视野测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Vision (Switzerland)
Vision (Switzerland) Health Professions-Optometry
CiteScore
2.30
自引率
0.00%
发文量
62
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书