Evaluating the Effect of Drug Loading on the Acoustic Response of Nanobubbles in Stable and Inertial Cavitation Regimes

IF 1.8
Muhammad Saad Khan;Victoria Bulycheva;Charlotte Ferworn;Omar Falou;Eric M. Strohm;Pinunta Nittayacharn;Elizabeth Berndl;Raffi Karshafian;Agata A. Exner;Michael C. Kolios
{"title":"Evaluating the Effect of Drug Loading on the Acoustic Response of Nanobubbles in Stable and Inertial Cavitation Regimes","authors":"Muhammad Saad Khan;Victoria Bulycheva;Charlotte Ferworn;Omar Falou;Eric M. Strohm;Pinunta Nittayacharn;Elizabeth Berndl;Raffi Karshafian;Agata A. Exner;Michael C. Kolios","doi":"10.1109/OJUFFC.2025.3618629","DOIUrl":null,"url":null,"abstract":"Nanobubbles (NBs) have been investigated as ultrasound contrast agents and drug delivery carriers in medical applications. Previous studies have reported the efficacy of NBs in imaging and therapy. However, ultrasound (US) exposure parameters for stable and inertial cavitation of NBs need to be investigated. This study examines passive cavitation detection of ultrasound signatures from two types of NBs across three pressure ranges using passive cavitation detection (PCD), aiming to investigate their cavitation behaviour with and without the inclusion of the chemotherapeutic drug, Doxorubicin (HDox). We compared the power spectral density (PSD) of non-drug loaded Propylene-Glycol Glycerol (PGG) NBs and HDox NBs under 300 kPa, 600 kPa, and 900 kPa pressures at 1 MHz fundamental frequency and 1% duty cycle. Our results indicate that NBs exhibit stable cavitation at 300 kPa, while a mix of inertial and stable cavitation occur at 600 and 900 kPa. The loading of NBs with HDox affects their acoustic activity. HDox NBs exhibit higher acoustic activity at 300 kPa, but their PCD signal profile becomes similar to PGG NBs at 600 kPa and 900 kPa. A numerical model was used to gain additional insight into some of the characteristics of the NB power spectra observed. Our simulations indicate that nonlinear bubble oscillations are characterized by distinctly pronounced harmonics, particularly the third harmonic, with this effect being even more prominent in smaller bubbles and lower ultrasound amplitudes. These findings will help determine ultrasound pulse parameters in imaging and therapeutic applications.","PeriodicalId":73301,"journal":{"name":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","volume":"5 ","pages":"190-203"},"PeriodicalIF":1.8000,"publicationDate":"2025-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11195190","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11195190/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Nanobubbles (NBs) have been investigated as ultrasound contrast agents and drug delivery carriers in medical applications. Previous studies have reported the efficacy of NBs in imaging and therapy. However, ultrasound (US) exposure parameters for stable and inertial cavitation of NBs need to be investigated. This study examines passive cavitation detection of ultrasound signatures from two types of NBs across three pressure ranges using passive cavitation detection (PCD), aiming to investigate their cavitation behaviour with and without the inclusion of the chemotherapeutic drug, Doxorubicin (HDox). We compared the power spectral density (PSD) of non-drug loaded Propylene-Glycol Glycerol (PGG) NBs and HDox NBs under 300 kPa, 600 kPa, and 900 kPa pressures at 1 MHz fundamental frequency and 1% duty cycle. Our results indicate that NBs exhibit stable cavitation at 300 kPa, while a mix of inertial and stable cavitation occur at 600 and 900 kPa. The loading of NBs with HDox affects their acoustic activity. HDox NBs exhibit higher acoustic activity at 300 kPa, but their PCD signal profile becomes similar to PGG NBs at 600 kPa and 900 kPa. A numerical model was used to gain additional insight into some of the characteristics of the NB power spectra observed. Our simulations indicate that nonlinear bubble oscillations are characterized by distinctly pronounced harmonics, particularly the third harmonic, with this effect being even more prominent in smaller bubbles and lower ultrasound amplitudes. These findings will help determine ultrasound pulse parameters in imaging and therapeutic applications.
稳态空化和惯性空化条件下药物负载对纳米气泡声响应的影响
纳米气泡(NBs)作为超声造影剂和药物传递载体在医学上的应用已被研究。先前的研究报道了NBs在成像和治疗方面的疗效。然而,需要对NBs稳定空化和惯性空化的超声暴露参数进行研究。本研究使用被动空化检测(PCD)对两种NBs在三个压力范围内的超声特征进行被动空化检测,旨在研究它们在包含化疗药物阿霉素(HDox)和不包含化疗药物的情况下的空化行为。我们比较了在1 MHz基频和1%占空比下,在300 kPa、600 kPa和900 kPa压力下,非载药丙二醇甘油(PGG) NBs和HDox NBs的功率谱密度(PSD)。结果表明,NBs在300 kPa时表现出稳定空化,而在600和900 kPa时则出现惯性空化和稳定空化的混合现象。负载HDox的NBs会影响其声活性。HDox NBs在300 kPa时表现出更高的声活性,但其PCD信号分布在600 kPa和900 kPa时与PGG NBs相似。一个数值模型被用来对观测到的NB功率谱的一些特征获得更多的了解。我们的模拟表明,非线性气泡振荡的特征是明显明显的谐波,特别是三次谐波,这种影响在较小的气泡和较低的超声振幅中更加突出。这些发现将有助于确定成像和治疗应用中的超声脉冲参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书