Amperometric biosensors: Why might the response show a logarithmic dependence on analyte concentration?

IF 4.2 3区 工程技术 Q2 ELECTROCHEMISTRY
Electrochemistry Communications Pub Date : 2025-12-01 Epub Date: 2025-10-22 DOI:10.1016/j.elecom.2025.108064
Morgan P. Milner , Stanislav V. Sokolov , Richard G. Compton
{"title":"Amperometric biosensors: Why might the response show a logarithmic dependence on analyte concentration?","authors":"Morgan P. Milner ,&nbsp;Stanislav V. Sokolov ,&nbsp;Richard G. Compton","doi":"10.1016/j.elecom.2025.108064","DOIUrl":null,"url":null,"abstract":"<div><div>Amperometric biosensors of different designs are often reported as having a logarithmic dependency on the target concentration. This paper provides a physicochemical basis for this behaviour if the adsorption of the analyte follows the Temkin Adsorption Isotherm over the range of concentrations of interest either by directly controlling the amount adsorbed or indirectly via the effect on the electrochemical rate constant.</div></div>","PeriodicalId":304,"journal":{"name":"Electrochemistry Communications","volume":"181 ","pages":"Article 108064"},"PeriodicalIF":4.2000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrochemistry Communications","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1388248125002048","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

Abstract

Amperometric biosensors of different designs are often reported as having a logarithmic dependency on the target concentration. This paper provides a physicochemical basis for this behaviour if the adsorption of the analyte follows the Temkin Adsorption Isotherm over the range of concentrations of interest either by directly controlling the amount adsorbed or indirectly via the effect on the electrochemical rate constant.
安培生物传感器:为什么响应可能显示对分析物浓度的对数依赖?
不同设计的安培生物传感器通常被报道为对目标浓度具有对数依赖性。本文为这种行为提供了物理化学基础,如果被分析物的吸附在感兴趣的浓度范围内遵循Temkin吸附等温线,要么直接控制吸附量,要么间接通过对电化学速率常数的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Electrochemistry Communications
Electrochemistry Communications 工程技术-电化学
CiteScore
8.50
自引率
3.70%
发文量
160
审稿时长
1.2 months
期刊介绍: Electrochemistry Communications is an open access journal providing fast dissemination of short communications, full communications and mini reviews covering the whole field of electrochemistry which merit urgent publication. Short communications are limited to a maximum of 20,000 characters (including spaces) while full communications and mini reviews are limited to 25,000 characters (including spaces). Supplementary information is permitted for full communications and mini reviews but not for short communications. We aim to be the fastest journal in electrochemistry for these types of papers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书