{"title":"Pitfalls in ICU EEG Interpretation: A Retrospective Case Series.","authors":"Aybuke Acar, Brin E Freund, William O Tatum, Anteneh M Feyissa","doi":"10.1177/19418744251391257","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Electroencephalography (EEG) is increasingly used in intensive care units (ICUs), primarily for seizure detection. However, the complex clinical context of critically ill patients and the dynamic ICU environment can complicate interpretation. <b>Purpose:</b> To highlight common pitfalls in ICU EEG interpretation and strategies to distinguish epileptic seizures from mimics. <b>Research Design:</b> Retrospective case series. <b>Study Sample:</b> Five ICU patients undergoing continuous video EEG (cvEEG) for altered mental status, status epilepticus, or paroxysmal events, with underlying conditions including malignancy, autoimmune encephalitis, neuromodulation therapy, and drug-resistant epilepsy. <b>Results:</b> Physiological artifacts, such as non-epileptic rhythmic movements, and device-related artifacts (e.g., pacemakers, ventilators) can mimic epileptic seizures. Plateau waves from elevated intracranial pressure may produce deficits resembling epileptic seizures. Accurate differentiation requires attention to clinical context, EEG features, and video correlation. Maintaining a broad differential and avoiding diagnostic anchoring are also essential to prevent misdiagnosis and unnecessary antiseizure medication therapy. <b>Conclusions:</b> ICU EEG interpretation is challenged by artifacts and non-epileptic movements that mimic epileptic seizures. Awareness of these issues, along with a thoughtful, multidisciplinary approach, is critical for improving diagnostic accuracy and optimizing patient outcomes during cvEEG monitoring.</p>","PeriodicalId":46355,"journal":{"name":"Neurohospitalist","volume":" ","pages":"191-196"},"PeriodicalIF":0.6000,"publicationDate":"2025-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12535583/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurohospitalist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19418744251391257","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Electroencephalography (EEG) is increasingly used in intensive care units (ICUs), primarily for seizure detection. However, the complex clinical context of critically ill patients and the dynamic ICU environment can complicate interpretation. Purpose: To highlight common pitfalls in ICU EEG interpretation and strategies to distinguish epileptic seizures from mimics. Research Design: Retrospective case series. Study Sample: Five ICU patients undergoing continuous video EEG (cvEEG) for altered mental status, status epilepticus, or paroxysmal events, with underlying conditions including malignancy, autoimmune encephalitis, neuromodulation therapy, and drug-resistant epilepsy. Results: Physiological artifacts, such as non-epileptic rhythmic movements, and device-related artifacts (e.g., pacemakers, ventilators) can mimic epileptic seizures. Plateau waves from elevated intracranial pressure may produce deficits resembling epileptic seizures. Accurate differentiation requires attention to clinical context, EEG features, and video correlation. Maintaining a broad differential and avoiding diagnostic anchoring are also essential to prevent misdiagnosis and unnecessary antiseizure medication therapy. Conclusions: ICU EEG interpretation is challenged by artifacts and non-epileptic movements that mimic epileptic seizures. Awareness of these issues, along with a thoughtful, multidisciplinary approach, is critical for improving diagnostic accuracy and optimizing patient outcomes during cvEEG monitoring.

ICU脑电图解释的缺陷:回顾性病例系列。
背景:脑电图(EEG)越来越多地用于重症监护病房(icu),主要用于癫痫发作检测。然而,危重患者复杂的临床背景和动态的ICU环境可能使解释复杂化。目的:强调ICU脑电图解释的常见缺陷和区分癫痫发作与模仿的策略。研究设计:回顾性病例系列。研究样本:5例ICU患者因精神状态改变、癫痫持续状态或发作性事件接受连续视频脑电图(cvEEG)检查,潜在疾病包括恶性肿瘤、自身免疫性脑炎、神经调节治疗和耐药癫痫。结果:生理伪影,如非癫痫性节律性运动和器械相关伪影(如起搏器、呼吸机)可以模拟癫痫发作。颅内压升高引起的平台波可能产生类似癫痫发作的缺陷。准确的鉴别需要注意临床背景、脑电图特征和视频相关性。保持广泛的鉴别和避免诊断锚定也是必不可少的,以防止误诊和不必要的抗癫痫药物治疗。结论:ICU脑电图解释受到伪影和模仿癫痫发作的非癫痫性运动的挑战。对这些问题的认识,以及深思熟虑的多学科方法,对于提高诊断准确性和优化cvEEG监测期间的患者预后至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Neurohospitalist
Neurohospitalist CLINICAL NEUROLOGY-
CiteScore
1.60
自引率
0.00%
发文量
108
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书