Development of dental implant drill with detection mechanism of bone quality change.

IF 4.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Takahiro Nozaki, Seiji Asoda, Soya Shimizu, Ryo Kondo, Koji Niwa, Masaki Yazawa, Kazuo Kishi, Hiromasa Kawana
{"title":"Development of dental implant drill with detection mechanism of bone quality change.","authors":"Takahiro Nozaki, Seiji Asoda, Soya Shimizu, Ryo Kondo, Koji Niwa, Masaki Yazawa, Kazuo Kishi, Hiromasa Kawana","doi":"10.1186/s40729-025-00650-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aims to develop and evaluate a dental implant drill system capable of preventing maxillary sinus membrane perforation, a common complication in cases with limited alveolar bone height, particularly in the maxillary molar region. The primary objective is to design a mechanism that autonomously detects changes in bone quality and halts drill rotation upon reaching the sinus floor.</p><p><strong>Methods: </strong>A novel dental implant drill incorporating an integrated bone quality detection mechanism was developed. The system includes a centrally mounted detector that actuates a switch controlling drill rotation. When cortical bone is penetrated and softer tissue is encountered, the detector extends outward, interrupting power to the motor. A penetration test was conducted using a 5 mm thick wooden board as a surrogate bone model to evaluate the drill's response to cortical penetration.</p><p><strong>Results: </strong>Experimental trials demonstrated that the drill automatically ceased rotation upon advancing approximately 0.47 mm beyond a simulated bone surface. Given that the maxillary sinus membrane is typically less than 1 mm in thickness, this minimal protrusion indicates a significantly reduced risk of perforation.</p><p><strong>Conclusion: </strong>The proposed drill system effectively detects transitions in bone quality and prevents over-penetration, offering a promising solution for enhancing surgical safety during maxillary implant procedures.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"11 1","pages":"65"},"PeriodicalIF":4.7000,"publicationDate":"2025-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12540961/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-025-00650-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aims to develop and evaluate a dental implant drill system capable of preventing maxillary sinus membrane perforation, a common complication in cases with limited alveolar bone height, particularly in the maxillary molar region. The primary objective is to design a mechanism that autonomously detects changes in bone quality and halts drill rotation upon reaching the sinus floor.

Methods: A novel dental implant drill incorporating an integrated bone quality detection mechanism was developed. The system includes a centrally mounted detector that actuates a switch controlling drill rotation. When cortical bone is penetrated and softer tissue is encountered, the detector extends outward, interrupting power to the motor. A penetration test was conducted using a 5 mm thick wooden board as a surrogate bone model to evaluate the drill's response to cortical penetration.

Results: Experimental trials demonstrated that the drill automatically ceased rotation upon advancing approximately 0.47 mm beyond a simulated bone surface. Given that the maxillary sinus membrane is typically less than 1 mm in thickness, this minimal protrusion indicates a significantly reduced risk of perforation.

Conclusion: The proposed drill system effectively detects transitions in bone quality and prevents over-penetration, offering a promising solution for enhancing surgical safety during maxillary implant procedures.

Abstract Image

Abstract Image

Abstract Image

具有骨质量变化检测机制的牙种植钻的研制。
目的:本研究旨在开发和评估一种能够预防上颌窦膜穿孔的种植体钻孔系统,上颌窦膜穿孔是牙槽骨高度有限的情况下常见的并发症,特别是在上颌磨牙区。主要目的是设计一种机制,自主检测骨质量的变化,并在到达窦底时停止钻头旋转。方法:研制了一种集成骨质量检测机制的新型种植牙钻。该系统包括一个中央安装的探测器,该探测器驱动控制钻头旋转的开关。当穿透皮质骨并遇到较软的组织时,探测器向外延伸,中断电机的电源。采用5mm厚的木板作为替代骨模型进行穿透试验,以评估钻头对皮质穿透的反应。结果:实验表明,钻头在超过模拟骨表面约0.47 mm时自动停止旋转。考虑到上颌窦膜的厚度通常小于1mm,这种最小的突出表明穿孔的风险显著降低。结论:所提出的钻头系统能有效检测骨质量的变化,防止过度穿透,为提高上颌种植过程中的手术安全性提供了一种有希望的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书