Effect of cathodic arc plasma spraying on shear bond strength between polyether ether ketone and maxillofacial silicone after accelerated aging - An in vitro study.

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Ganesh Ramkumar Rajapandi, Ahila Singaravel Chidambaranathan, Muthukumar Balasubramanium
{"title":"Effect of cathodic arc plasma spraying on shear bond strength between polyether ether ketone and maxillofacial silicone after accelerated aging - An in vitro study.","authors":"Ganesh Ramkumar Rajapandi, Ahila Singaravel Chidambaranathan, Muthukumar Balasubramanium","doi":"10.4103/jips.jips_203_25","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To evaluate and compare the shear bond strength between polyether ether ketone (PEEK) and maxillofacial silicone after cathodic arc plasma spraying and accelerated aging.</p><p><strong>Settings and design: </strong>An in vitro study.</p><p><strong>Materials and methods: </strong>According to ISO 10477:2020, 72 PEEK specimens were fabricated using computer-aided design/computer-aided manufacturing with 10-mm diameter and 3-mm thickness, and the silicone specimens were made with 5-mm diameter with 2.5-mm height. The specimens were categorized into Group 1 - No surface treatment, Group 2 - Cathodic arc plasma spraying, and Group 3 - Primer application. The silicone specimens were bonded to PEEK and subjected to accelerated aging for 252 and 504 h. The shear bond strength was performed using a universal testing machine at 1 mm/min crosshead speed.</p><p><strong>Statistical analysis used: </strong>One-way ANOVA, Tukey HSD test, and Student's t-test, where P < 0.5 was set as significant.</p><p><strong>Results: </strong>PEEK specimens subjected to primer application exhibited highest shear bond strength of 19.22 ± 0.35 Mpa, 18.55 ± 0.60 Mpa, 18.14 ± 0.65 Mpa, followed by cathodic arc plasma spraying 14.71 ± 0.28 Mpa, 13.54 ± 0.42 Mpa, 12.46 ± 0.48 Mpa after 24 h of fabrication, 252 h, and 504 h of aging and the least shear bond strength exhibited by control 4.98 ± 0.32, Mpa, 4.52 ± 0.33 Mpa, 4.2 ± 0.39 Mpa, respectively. The significance value P = 0.0001, which was <0.05. Hence, the results were found to be statistically significant.</p><p><strong>Conclusion: </strong>The maximum shear bond strength between PEEK and maxillofacial silicone was seen after primer application, followed by cathodic arc plasma surface treatment. Increasing the aging hours from 252 to 504 h, the shear bond strength was relatively reduced between PEEK and maxillofacial silicone.</p>","PeriodicalId":22669,"journal":{"name":"The Journal of Indian Prosthodontic Society","volume":"25 4","pages":"305-311"},"PeriodicalIF":1.0000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Indian Prosthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jips.jips_203_25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: To evaluate and compare the shear bond strength between polyether ether ketone (PEEK) and maxillofacial silicone after cathodic arc plasma spraying and accelerated aging.

Settings and design: An in vitro study.

Materials and methods: According to ISO 10477:2020, 72 PEEK specimens were fabricated using computer-aided design/computer-aided manufacturing with 10-mm diameter and 3-mm thickness, and the silicone specimens were made with 5-mm diameter with 2.5-mm height. The specimens were categorized into Group 1 - No surface treatment, Group 2 - Cathodic arc plasma spraying, and Group 3 - Primer application. The silicone specimens were bonded to PEEK and subjected to accelerated aging for 252 and 504 h. The shear bond strength was performed using a universal testing machine at 1 mm/min crosshead speed.

Statistical analysis used: One-way ANOVA, Tukey HSD test, and Student's t-test, where P < 0.5 was set as significant.

Results: PEEK specimens subjected to primer application exhibited highest shear bond strength of 19.22 ± 0.35 Mpa, 18.55 ± 0.60 Mpa, 18.14 ± 0.65 Mpa, followed by cathodic arc plasma spraying 14.71 ± 0.28 Mpa, 13.54 ± 0.42 Mpa, 12.46 ± 0.48 Mpa after 24 h of fabrication, 252 h, and 504 h of aging and the least shear bond strength exhibited by control 4.98 ± 0.32, Mpa, 4.52 ± 0.33 Mpa, 4.2 ± 0.39 Mpa, respectively. The significance value P = 0.0001, which was <0.05. Hence, the results were found to be statistically significant.

Conclusion: The maximum shear bond strength between PEEK and maxillofacial silicone was seen after primer application, followed by cathodic arc plasma surface treatment. Increasing the aging hours from 252 to 504 h, the shear bond strength was relatively reduced between PEEK and maxillofacial silicone.

阴极电弧等离子喷涂对加速老化后聚醚醚酮与颌面硅胶剪切结合强度的影响——体外研究。
目的:评价和比较聚醚醚酮(PEEK)与颌面部硅胶经阴极电弧等离子喷涂和加速老化后的剪切结合强度。设置和设计:一项体外研究。材料与方法:根据ISO 10477:2020,采用计算机辅助设计/计算机辅助制造方法制作72个直径为10mm、厚度为3mm的PEEK试件,制作直径为5mm、高度为2.5 mm的硅胶试件。试样分为三组,第一组为无表面处理,第二组为阴极电弧等离子喷涂,第三组为底漆。将硅胶试件与PEEK粘结,分别进行252和504 h的加速老化。在万能试验机上以1 mm/min的十字速度进行剪切粘结强度测试。统计分析采用单因素方差分析、Tukey HSD检验和学生t检验,其中P < 0.5为显著性。结果:涂底漆的PEEK试样在制备24 h、时效252 h和504 h后的剪切强度最高,分别为19.22±0.35 Mpa、18.55±0.60 Mpa和18.14±0.65 Mpa,阴极电弧等离子喷涂次之,分别为14.71±0.28 Mpa、13.54±0.42 Mpa、12.46±0.48 Mpa,对照组的剪切强度最低,分别为4.98±0.32 Mpa、4.52±0.33 Mpa和4.2±0.39 Mpa。结论:聚醚醚酮与颌面部有机硅的剪切结合强度在涂底漆后最大,其次为阴极电弧等离子体表面处理。老化时间从252小时增加到504小时,PEEK与颌面硅胶的剪切结合强度相对降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
The Journal of Indian Prosthodontic Society
The Journal of Indian Prosthodontic Society DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.20
自引率
8.30%
发文量
26
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信