Comparison of the quality of prostate images from different diffusion-weighted imaging sequences: Single-shot echo-planar, reduced field-of-view, readout-segmented multi-shot.
IF 1.1 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Li Xu, Along Qiao, Fei Li, Xiaoyan Zhang, Rui Wu, Wenya Liu, Bo Jiang, Minghua Sun
{"title":"Comparison of the quality of prostate images from different diffusion-weighted imaging sequences: Single-shot echo-planar, reduced field-of-view, readout-segmented multi-shot.","authors":"Li Xu, Along Qiao, Fei Li, Xiaoyan Zhang, Rui Wu, Wenya Liu, Bo Jiang, Minghua Sun","doi":"10.25259/JCIS_64_2025","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The objectives of the study are to compare the prostate image quality (IQ) obtained with single-shot echo-planar diffusion-weighted imaging (ss-DWI), reduced field-of-view diffusion-weighted imaging (rf-DWI), and readout-segmented multi-shot diffusion-weighted imaging (rs-DWI), along with their diagnostic efficacy for clinically significant prostate cancer (csPCa), to optimize prostate magnetic resonance diffusion-weighted imaging sequences.</p><p><strong>Material and methods: </strong>We have analyzed prostate images from 72 patients who underwent ss-DWI, rs-DWI, and rf-DWI magnetic resonance imaging (MRI) scans from March 2023 to September 2024. Two radiologists qualitatively evaluated the IQ of three diffusion-weighted imaging (DWI) sequences and corresponding apparent diffusion coefficient (ADC) images as well as Prostate Imaging Reporting and Data System Version 2.1 (PI-RADS v2.1) category of prostate nodules and measured the anterior-posterior diameter and right-left (RL) diameters of the prostate on both types of images and ADC values of prostate nodules. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Qualitative and quantitative differences across DWI techniques were statistically compared.</p><p><strong>Results: </strong>The rf-DWI images demonstrated optimal clarity, minimal distortion/artifacts, and the highest CNR and lowest SNR. The RL diameter of the prostate measured on T2-weighted images was larger than those on ss-DWI images, and the RL diameter measured on ss-DWI images was smaller than those measured on rf-DWI images (<i>P</i> < 0.05). The rf-DWI-based PI-RADS v2.1 categorization and ADC values showed higher diagnostic accuracy for csPCa versus ss-DWI/rs-DWI, with optimal ADC cutoffs of 0.958 × 10<sup>3</sup> mm<sup>2</sup>/s (transition zone) and 0.769 × 10<sup>3</sup> mm<sup>2</sup>/s (peripheral zone).</p><p><strong>Conclusion: </strong>Compared to ss-DWI and rs-DWI, the rf-DWI sequence demonstrates optimal IQ and quantitative parameters with the optimum diagnostic performance for csPCa, making it the best choice for prostate scans.</p>","PeriodicalId":15512,"journal":{"name":"Journal of Clinical Imaging Science","volume":"15 ","pages":"36"},"PeriodicalIF":1.1000,"publicationDate":"2025-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12530774/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Imaging Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/JCIS_64_2025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: The objectives of the study are to compare the prostate image quality (IQ) obtained with single-shot echo-planar diffusion-weighted imaging (ss-DWI), reduced field-of-view diffusion-weighted imaging (rf-DWI), and readout-segmented multi-shot diffusion-weighted imaging (rs-DWI), along with their diagnostic efficacy for clinically significant prostate cancer (csPCa), to optimize prostate magnetic resonance diffusion-weighted imaging sequences.
Material and methods: We have analyzed prostate images from 72 patients who underwent ss-DWI, rs-DWI, and rf-DWI magnetic resonance imaging (MRI) scans from March 2023 to September 2024. Two radiologists qualitatively evaluated the IQ of three diffusion-weighted imaging (DWI) sequences and corresponding apparent diffusion coefficient (ADC) images as well as Prostate Imaging Reporting and Data System Version 2.1 (PI-RADS v2.1) category of prostate nodules and measured the anterior-posterior diameter and right-left (RL) diameters of the prostate on both types of images and ADC values of prostate nodules. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Qualitative and quantitative differences across DWI techniques were statistically compared.
Results: The rf-DWI images demonstrated optimal clarity, minimal distortion/artifacts, and the highest CNR and lowest SNR. The RL diameter of the prostate measured on T2-weighted images was larger than those on ss-DWI images, and the RL diameter measured on ss-DWI images was smaller than those measured on rf-DWI images (P < 0.05). The rf-DWI-based PI-RADS v2.1 categorization and ADC values showed higher diagnostic accuracy for csPCa versus ss-DWI/rs-DWI, with optimal ADC cutoffs of 0.958 × 103 mm2/s (transition zone) and 0.769 × 103 mm2/s (peripheral zone).
Conclusion: Compared to ss-DWI and rs-DWI, the rf-DWI sequence demonstrates optimal IQ and quantitative parameters with the optimum diagnostic performance for csPCa, making it the best choice for prostate scans.
期刊介绍:
The Journal of Clinical Imaging Science (JCIS) is an open access peer-reviewed journal committed to publishing high-quality articles in the field of Imaging Science. The journal aims to present Imaging Science and relevant clinical information in an understandable and useful format. The journal is owned and published by the Scientific Scholar. Audience Our audience includes Radiologists, Researchers, Clinicians, medical professionals and students. Review process JCIS has a highly rigorous peer-review process that makes sure that manuscripts are scientifically accurate, relevant, novel and important. Authors disclose all conflicts, affiliations and financial associations such that the published content is not biased.