The impact of alloy treatment on the dynamic cyclic fatigue resistance of triangular base cross-section NiTi endodontic instruments.

IF 2.4 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Rashid El Abed, Amre R Atmeh, Mohamed Jamal, Anas Al Jadaa, Hamza El-Faraj, Abdel Rahman Bani Amer, Taher Al Omari
{"title":"The impact of alloy treatment on the dynamic cyclic fatigue resistance of triangular base cross-section NiTi endodontic instruments.","authors":"Rashid El Abed, Amre R Atmeh, Mohamed Jamal, Anas Al Jadaa, Hamza El-Faraj, Abdel Rahman Bani Amer, Taher Al Omari","doi":"10.1007/s10266-025-01230-1","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the dynamic cyclic fatigue resistance and bending forces of small-sized blue heat-treated files with comparable cross sections but varying geometries at simulated intracanal temperature. For each system, Race Evo (RE), ZenFlex (ZF) and Tia Tornado Blue (TTB), 20 new files were tested (n = 20). Twelve files (n = 12) were subjected to Dynamic Cyclic Fatigue testing in an artificial canal (18 mm length, 1.4 mm diameter, 45° curvature, 5 mm radius) at 34 °C. Five files (n = 5) were used for static bending tests at 34 °C. Two files (n = 2) were used for differential scanning calorimetry (DSC) and X-ray diffraction (XRD), and one (n = 1) unused file was used for geometric evaluation using stereomicroscopy and scanning electron microscopy (SEM). TTB exhibited significantly higher fatigue resistance (1512 NCF) than ZF (1234 NCF; P < 0.05), while RE showed intermediate performance (1385 NCF). RE has the shortest fragment length at 3.25 mm, which represents a significant difference compared to ZF (4.55 mm; P < 0.05) and TTB (5.1 mm; P < 0.05), respectively. TTB required the lowest mean force, 0.304 N (P < 0.05), to bend, which was a statistically significant difference compared to RE (0.361 N) and ZF (0.425 N), respectively. ZF has been shown to lack an R-phase during heating, whereas other files have both an R-phase and an austenite phase. Blue heat treatment significantly enhanced fatigue resistance by stabilizing the R-phase, overriding the influence of pitch geometry. Heat treatment plays a more decisive role than pitch design in determining cyclic fatigue resistance.</p>","PeriodicalId":19390,"journal":{"name":"Odontology","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Odontology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10266-025-01230-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

This study evaluated the dynamic cyclic fatigue resistance and bending forces of small-sized blue heat-treated files with comparable cross sections but varying geometries at simulated intracanal temperature. For each system, Race Evo (RE), ZenFlex (ZF) and Tia Tornado Blue (TTB), 20 new files were tested (n = 20). Twelve files (n = 12) were subjected to Dynamic Cyclic Fatigue testing in an artificial canal (18 mm length, 1.4 mm diameter, 45° curvature, 5 mm radius) at 34 °C. Five files (n = 5) were used for static bending tests at 34 °C. Two files (n = 2) were used for differential scanning calorimetry (DSC) and X-ray diffraction (XRD), and one (n = 1) unused file was used for geometric evaluation using stereomicroscopy and scanning electron microscopy (SEM). TTB exhibited significantly higher fatigue resistance (1512 NCF) than ZF (1234 NCF; P < 0.05), while RE showed intermediate performance (1385 NCF). RE has the shortest fragment length at 3.25 mm, which represents a significant difference compared to ZF (4.55 mm; P < 0.05) and TTB (5.1 mm; P < 0.05), respectively. TTB required the lowest mean force, 0.304 N (P < 0.05), to bend, which was a statistically significant difference compared to RE (0.361 N) and ZF (0.425 N), respectively. ZF has been shown to lack an R-phase during heating, whereas other files have both an R-phase and an austenite phase. Blue heat treatment significantly enhanced fatigue resistance by stabilizing the R-phase, overriding the influence of pitch geometry. Heat treatment plays a more decisive role than pitch design in determining cyclic fatigue resistance.

合金处理对三角基截面NiTi根管器械动态循环疲劳抗力的影响。
在模拟管内温度下,本研究评估了具有相同截面但不同几何形状的小型蓝色热处理锉的动态循环疲劳抗力和弯曲力。对于Race Evo (RE)、ZenFlex (ZF)和Tia Tornado Blue (TTB)这三个系统,测试了20个新文件(n = 20)。12根锉(n = 12)在34°C的人工管(长18mm,直径1.4 mm,曲率45°,半径5mm)中进行动态循环疲劳试验。5个锉(n = 5)在34°C下进行静态弯曲试验。两个文件(n = 2)用于差示扫描量热法(DSC)和x射线衍射(XRD),一个(n = 1)未使用的文件用于立体显微镜和扫描电子显微镜(SEM)的几何评价。TTB的抗疲劳性能(1512 NCF)显著高于ZF (1234 NCF)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Odontology
Odontology 医学-牙科与口腔外科
CiteScore
5.30
自引率
4.00%
发文量
91
审稿时长
>12 weeks
期刊介绍: The Journal Odontology covers all disciplines involved in the fields of dentistry and craniofacial research, including molecular studies related to oral health and disease. Peer-reviewed articles cover topics ranging from research on human dental pulp, to comparisons of analgesics in surgery, to analysis of biofilm properties of dental plaque.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信