Investigating Aortic Root Hemodynamics With EVAHEART2 Pump Speed Modulation.

IF 2.2 3区 医学 Q2 ENGINEERING, BIOMEDICAL
ASAIO Journal Pub Date : 2026-09-01 Epub Date: 2025-10-15 DOI:10.1097/MAT.0000000000002577
Jasmine Martinez, Ruth White, Vikash Shukla, Benjamin Diaz, Kelsey Smegner, Shinji Kobayashi, Tadashi Motomura, Venkat Keshav Chivukula
{"title":"Investigating Aortic Root Hemodynamics With EVAHEART2 Pump Speed Modulation.","authors":"Jasmine Martinez, Ruth White, Vikash Shukla, Benjamin Diaz, Kelsey Smegner, Shinji Kobayashi, Tadashi Motomura, Venkat Keshav Chivukula","doi":"10.1097/MAT.0000000000002577","DOIUrl":null,"url":null,"abstract":"<p><p>Left ventricular assist device (LVAD) therapy often reduces the chances of aortic valve opening (AVO), increasing the risk of blood stagnation and thrombus formation. The EVAHEART2 (EVA2) pump speed modulation (PSM) can be leveraged to mitigate these risks by encouraging AVO. Study aims to i) investigate how PSM impacts aortic root hemodynamics, ii) quantify how much transaortic valve flow is needed to washout the aortic root, and iii) evaluate how PSM may alter pulsatility in LVAD flow. Computational fluid dynamics simulations were used to quantify aortic root washout, washout progression, and perform platelet tracking to evaluate thrombogenic potential. Results showed that when the aortic valve (AV) was closed, only 60% of blood was washed out after 4 seconds, whereas AVO significantly increased washout efficiency, clearing over 80% of blood within 3 seconds. Platelet tracking revealed that platelets were up to 60% more likely to stagnate for a nonfunctional AV compared with transaortic flow scenarios. Higher transaortic flow had the lowest thrombogenic potential score. These findings demonstrate that transaortic valve flow is the primary factor driving aortic root washout. Using EVA2 PSM settings to enhance transaortic valve flow can improve aortic root washout. This study emphasizes the importance of strategies that enable LVAD patients to have a functional AV.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":"740-749"},"PeriodicalIF":2.2000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002577","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Left ventricular assist device (LVAD) therapy often reduces the chances of aortic valve opening (AVO), increasing the risk of blood stagnation and thrombus formation. The EVAHEART2 (EVA2) pump speed modulation (PSM) can be leveraged to mitigate these risks by encouraging AVO. Study aims to i) investigate how PSM impacts aortic root hemodynamics, ii) quantify how much transaortic valve flow is needed to washout the aortic root, and iii) evaluate how PSM may alter pulsatility in LVAD flow. Computational fluid dynamics simulations were used to quantify aortic root washout, washout progression, and perform platelet tracking to evaluate thrombogenic potential. Results showed that when the aortic valve (AV) was closed, only 60% of blood was washed out after 4 seconds, whereas AVO significantly increased washout efficiency, clearing over 80% of blood within 3 seconds. Platelet tracking revealed that platelets were up to 60% more likely to stagnate for a nonfunctional AV compared with transaortic flow scenarios. Higher transaortic flow had the lowest thrombogenic potential score. These findings demonstrate that transaortic valve flow is the primary factor driving aortic root washout. Using EVA2 PSM settings to enhance transaortic valve flow can improve aortic root washout. This study emphasizes the importance of strategies that enable LVAD patients to have a functional AV.

用EVAHEART2泵调速研究主动脉根部血流动力学。
左心室辅助装置(LVAD)治疗通常会降低主动脉瓣打开(AVO)的机会,增加血液停滞和血栓形成的风险。EVAHEART2 (EVA2)泵速调制(PSM)可以通过鼓励AVO来降低这些风险。该研究旨在i)研究PSM如何影响主动脉根部血流动力学,ii)量化冲洗主动脉根部需要多少经主动脉瓣血流,以及iii)评估PSM如何改变LVAD血流中的脉搏。计算流体动力学模拟用于量化主动脉根部冲洗,冲洗进展,并进行血小板跟踪以评估血栓形成潜力。结果表明,当主动脉瓣关闭时,4秒后只有60%的血液被洗出,而AVO明显提高了洗出效率,3秒内清除了80%以上的血液。血小板追踪显示,与经主动脉血流情况相比,无功能房室患者血小板停滞的可能性高达60%。主动脉流量越高,血栓形成潜力评分越低。这些结果表明,经主动脉瓣血流是导致主动脉根部冲洗的主要因素。使用EVA2 PSM设置增强经主动脉瓣血流可以改善主动脉根部冲洗。本研究强调了使LVAD患者拥有功能性房室的策略的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ASAIO Journal
ASAIO Journal 医学-工程:生物医学
CiteScore
6.60
自引率
7.10%
发文量
651
审稿时长
4-8 weeks
期刊介绍: ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world. The official publication of the American Society for Artificial Internal Organs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书