Labyrinthine Signal Intensity on Non-contrast-enhanced 3D-real Inversion Recovery MR Imaging: Correlation with the Endolymphatic Volume Measured on Contrast-enhanced HYDROPS-Mi2.
{"title":"Labyrinthine Signal Intensity on Non-contrast-enhanced 3D-real Inversion Recovery MR Imaging: Correlation with the Endolymphatic Volume Measured on Contrast-enhanced HYDROPS-Mi2.","authors":"Toshio Ohashi, Shinji Naganawa, Ryo Yamamoto, Kayao Kuno","doi":"10.2463/mrms.mp.2025-0068","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the relationship between the signal intensity (SI) of the entire labyrinthine fluid on non-contrast-enhanced 3D real inversion recovery (3D-real IR) imaging and the endolymphatic volume measured on contrast-enhanced HYDROPS-Mi2 (HYbriD of Reversed image Of Positive endolymph signal and native image of positive perilymph Signal image Multiplied with hT2w MR cisternography) imaging.</p><p><strong>Methods: </strong>This retrospective study included 37 patients (74 ears) with suspected endolymphatic hydrops (EH). The volume ratio of the endolymphatic space (%EL<sub>vol</sub>) was measured on contrast-enhanced HYDROPS-Mi2 images, and the normalized volume-averaged signal intensity (nSI<sub>vol</sub>) of the entire labyrinthine fluid was measured on non-contrast-enhanced 3D-real IR images. Statistical analyses included comparisons of nSI<sub>vol</sub> between the cochlea and vestibule, side-to-side differences in EH-negative ears, paired comparisons of nSI<sub>vol</sub> between larger- and smaller-%EL<sub>vol</sub> sides, correlations between %EL<sub>vol</sub> and nSI<sub>vol</sub>, and receiver operating characteristic (ROC) curve analysis of nSI<sub>vol</sub> for discriminating severe from mild/no EH. The presence of EH was defined based on the clinical diagnosis using Nakashima grading.</p><p><strong>Results: </strong>The vestibular %EL<sub>vol</sub> was significantly higher and the vestibular nSI<sub>vol</sub> significantly lower than that in the cochlea (both P < 0.001). In EH-negative ears, no significant side-to-side difference in nSI<sub>vol</sub> was observed. In both cochleae and vestibules, nSI<sub>vol</sub> was significantly lower on the larger-%EL<sub>vol</sub> side than on the smaller-%EL<sub>vol</sub> side (cochlea: P = 0.002; vestibule: P = 0.007). Significant negative correlations between %EL<sub>vol</sub> and nSI<sub>vol</sub> were observed in both the cochlea (Spearman's rank correlation coefficient [R<sub>s</sub>] = -0.598, P < 0.001) and vestibule (R<sub>s</sub> = -0.417, P < 0.001). The area under the ROC curve was 0.827 in the cochlea, and 0.698 in the vestibule.</p><p><strong>Conclusion: </strong>The SI of the entire labyrinthine fluid measured on non-contrast-enhanced 3D-real IR imaging showed a significant negative correlation with the endolymphatic volume measured on contrast-enhanced HYDROPS-Mi2. These findings suggest that the SI of labyrinthine fluid, as measured on non-contrast-enhanced 3D-real IR images, may serve as an indirect indicator for estimating the degree of EH.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2026-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13041244/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2025-0068","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/11 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To investigate the relationship between the signal intensity (SI) of the entire labyrinthine fluid on non-contrast-enhanced 3D real inversion recovery (3D-real IR) imaging and the endolymphatic volume measured on contrast-enhanced HYDROPS-Mi2 (HYbriD of Reversed image Of Positive endolymph signal and native image of positive perilymph Signal image Multiplied with hT2w MR cisternography) imaging.
Methods: This retrospective study included 37 patients (74 ears) with suspected endolymphatic hydrops (EH). The volume ratio of the endolymphatic space (%ELvol) was measured on contrast-enhanced HYDROPS-Mi2 images, and the normalized volume-averaged signal intensity (nSIvol) of the entire labyrinthine fluid was measured on non-contrast-enhanced 3D-real IR images. Statistical analyses included comparisons of nSIvol between the cochlea and vestibule, side-to-side differences in EH-negative ears, paired comparisons of nSIvol between larger- and smaller-%ELvol sides, correlations between %ELvol and nSIvol, and receiver operating characteristic (ROC) curve analysis of nSIvol for discriminating severe from mild/no EH. The presence of EH was defined based on the clinical diagnosis using Nakashima grading.
Results: The vestibular %ELvol was significantly higher and the vestibular nSIvol significantly lower than that in the cochlea (both P < 0.001). In EH-negative ears, no significant side-to-side difference in nSIvol was observed. In both cochleae and vestibules, nSIvol was significantly lower on the larger-%ELvol side than on the smaller-%ELvol side (cochlea: P = 0.002; vestibule: P = 0.007). Significant negative correlations between %ELvol and nSIvol were observed in both the cochlea (Spearman's rank correlation coefficient [Rs] = -0.598, P < 0.001) and vestibule (Rs = -0.417, P < 0.001). The area under the ROC curve was 0.827 in the cochlea, and 0.698 in the vestibule.
Conclusion: The SI of the entire labyrinthine fluid measured on non-contrast-enhanced 3D-real IR imaging showed a significant negative correlation with the endolymphatic volume measured on contrast-enhanced HYDROPS-Mi2. These findings suggest that the SI of labyrinthine fluid, as measured on non-contrast-enhanced 3D-real IR images, may serve as an indirect indicator for estimating the degree of EH.