Sonographic nystagmus: a case report of lateral semicircular canal benign paroxysmal positional vertigo.

IF 3.6 Q2 Medicine
Yuki Munekata, Chisato Matsumoto, Kento Sakoda, Yuki Takahashi
{"title":"Sonographic nystagmus: a case report of lateral semicircular canal benign paroxysmal positional vertigo.","authors":"Yuki Munekata, Chisato Matsumoto, Kento Sakoda, Yuki Takahashi","doi":"10.1186/s13089-025-00457-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Nystagmus, a critical diagnostic sign of vertigo and dizziness, reflects disturbances in the vestibular system. The accurate characterisation of nystagmus aids in distinguishing between peripheral and central causes, such as benign paroxysmal positional vertigo (BPPV) and stroke, respectively. Traditional methods for assessing nystagmus involve visual inspection or the use of Frenzel goggles. However, in cases where patients are unable to keep their eyes open owing to severe vertigo, such an evaluation becomes challenging. To date, sonographic imaging has not been used as a diagnostic method for nystagmus. We present a case in which ocular ultrasonography was used to assess nystagmus and aid in the diagnosis of BPPV.</p><p><strong>Case presentation: </strong>A 56-year-old woman presented with recurrent vertigo exacerbated by positional changes. Clinical examination revealed no spontaneous nystagmus or neurological deficits. Because the patient was unable to keep her eyes open during positional testing, ocular ultrasonography was performed using a 9-MHz linear transducer. Imaging revealed direction-changing horizontal nystagmus, consistent with the apogeotropic variant of lateral semicircular canal BPPV. The diagnosis was subsequently confirmed by an otolaryngologist using Frenzel goggles. The patient was conservatively managed.</p><p><strong>Conclusions: </strong>This is the first report on the use of ocular ultrasonography to assess nystagmus. Despite certain limitations, this technique may be a valuable supplementary tool, particularly in settings in which conventional examinations are hindered or unavailable. Ophthalmic sonography has the potential to enhance vestibular assessments in emergency and outpatient settings.</p>","PeriodicalId":36911,"journal":{"name":"Ultrasound Journal","volume":"17 1","pages":"51"},"PeriodicalIF":3.6000,"publicationDate":"2025-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12521668/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13089-025-00457-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Nystagmus, a critical diagnostic sign of vertigo and dizziness, reflects disturbances in the vestibular system. The accurate characterisation of nystagmus aids in distinguishing between peripheral and central causes, such as benign paroxysmal positional vertigo (BPPV) and stroke, respectively. Traditional methods for assessing nystagmus involve visual inspection or the use of Frenzel goggles. However, in cases where patients are unable to keep their eyes open owing to severe vertigo, such an evaluation becomes challenging. To date, sonographic imaging has not been used as a diagnostic method for nystagmus. We present a case in which ocular ultrasonography was used to assess nystagmus and aid in the diagnosis of BPPV.

Case presentation: A 56-year-old woman presented with recurrent vertigo exacerbated by positional changes. Clinical examination revealed no spontaneous nystagmus or neurological deficits. Because the patient was unable to keep her eyes open during positional testing, ocular ultrasonography was performed using a 9-MHz linear transducer. Imaging revealed direction-changing horizontal nystagmus, consistent with the apogeotropic variant of lateral semicircular canal BPPV. The diagnosis was subsequently confirmed by an otolaryngologist using Frenzel goggles. The patient was conservatively managed.

Conclusions: This is the first report on the use of ocular ultrasonography to assess nystagmus. Despite certain limitations, this technique may be a valuable supplementary tool, particularly in settings in which conventional examinations are hindered or unavailable. Ophthalmic sonography has the potential to enhance vestibular assessments in emergency and outpatient settings.

超声眼震:外侧半规管良性阵发性位置性眩晕1例。
背景:眼球震颤是眩晕和头晕的重要诊断标志,反映了前庭系统的紊乱。准确描述眼球震颤有助于区分外周和中枢原因,如良性阵发性位置性眩晕(BPPV)和中风。评估眼球震颤的传统方法包括目视检查或使用Frenzel护目镜。然而,在患者由于严重眩晕而无法保持眼睛睁开的情况下,这样的评估变得具有挑战性。迄今为止,超声成像尚未被用作眼球震颤的诊断方法。我们提出一个病例,其中眼超声检查用于评估眼球震颤和帮助诊断BPPV。病例介绍:一名56岁女性,因体位改变而复发性眩晕加重。临床检查未发现自发性眼球震颤或神经功能障碍。由于患者在定位测试期间无法保持眼睛睁开,因此使用9 mhz线性换能器进行眼部超声检查。影像学显示为改变方向的水平眼震,与外侧半规管BPPV向地变相一致。随后耳鼻喉科医生使用Frenzel护目镜证实了诊断。病人接受保守治疗。结论:本文首次报道了用眼超声检查评价眼球震颤。尽管有一定的局限性,但这种技术可能是一种有价值的补充工具,特别是在常规检查受阻或无法进行的情况下。眼科超声检查有潜力加强前庭评估在急诊和门诊设置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasound Journal
Ultrasound Journal Health Professions-Radiological and Ultrasound Technology
CiteScore
6.80
自引率
2.90%
发文量
45
审稿时长
22 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书