Echocardiographic assessment of a novel blood-guiding accessory for left ventricular assist devices in swine.

0 CARDIAC & CARDIOVASCULAR SYSTEMS
Michelle Costa Galbas, Florian Meissner, Hendrik Straky, Johanna Reuter, Marius Schimmel, Martin Czerny, Wolfgang Bothe
{"title":"Echocardiographic assessment of a novel blood-guiding accessory for left ventricular assist devices in swine.","authors":"Michelle Costa Galbas, Florian Meissner, Hendrik Straky, Johanna Reuter, Marius Schimmel, Martin Czerny, Wolfgang Bothe","doi":"10.1093/icvts/ivaf168","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Left ventricular assist devices are part of the foundations of mechanical circulatory support. As such devices evolve in technology, so does their implantation techniques, becoming less invasive. We developed a novel blood-guiding accessory for less invasive implantation, redirecting the blood intracardially into the ascending aorta through a transaortic outflow.</p><p><strong>Methods: </strong>Ten healthy female swine (German Landrace, 104.4 ± 13.0 kg) underwent epicardial echocardiography before and after left ventricular assist device implantation. Cardiac geometry, aortic valve function and outflow positioning, were assessed before and after implantation.</p><p><strong>Results: </strong>Epicardial echocardiography revealed sufficient biventricular unloading after device implantation. The end-diastolic and end-systolic left ventricular diameters decreased by 16% and 20%, respectively. Retrograde unloading was displayed by smaller diameters in left and right atria at 22% and 25%, respectively. At baseline, one animal presented mild aortic regurgitation, unchanged under mechanical support, whereas one developed mild de novo insufficiency. The outflow graft was either well centered within the aortic valve (n = 3) or between two cusps.</p><p><strong>Conclusions: </strong>A left ventricular assist device with the accessory allowed sufficient ventricular unloading, preserving biventricular function. Although the outflow graft was well centered within the aortic valve in only 30% of the cases, no relevant aortic regurgitation was found in the acute setting. Chronic testing in larger samples is required to analyze results in long term.</p>","PeriodicalId":73406,"journal":{"name":"Interdisciplinary cardiovascular and thoracic surgery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interdisciplinary cardiovascular and thoracic surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/icvts/ivaf168","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Left ventricular assist devices are part of the foundations of mechanical circulatory support. As such devices evolve in technology, so does their implantation techniques, becoming less invasive. We developed a novel blood-guiding accessory for less invasive implantation, redirecting the blood intracardially into the ascending aorta through a transaortic outflow.

Methods: Ten healthy female swine (German Landrace, 104.4 ± 13.0 kg) underwent epicardial echocardiography before and after left ventricular assist device implantation. Cardiac geometry, aortic valve function and outflow positioning, were assessed before and after implantation.

Results: Epicardial echocardiography revealed sufficient biventricular unloading after device implantation. The end-diastolic and end-systolic left ventricular diameters decreased by 16% and 20%, respectively. Retrograde unloading was displayed by smaller diameters in left and right atria at 22% and 25%, respectively. At baseline, one animal presented mild aortic regurgitation, unchanged under mechanical support, whereas one developed mild de novo insufficiency. The outflow graft was either well centered within the aortic valve (n = 3) or between two cusps.

Conclusions: A left ventricular assist device with the accessory allowed sufficient ventricular unloading, preserving biventricular function. Although the outflow graft was well centered within the aortic valve in only 30% of the cases, no relevant aortic regurgitation was found in the acute setting. Chronic testing in larger samples is required to analyze results in long term.

猪左心室辅助装置新型导血辅助装置的超声心动图评价。
目的:左心室辅助装置是机械循环支持的基础之一。随着这些设备在技术上的发展,它们的植入技术也在不断发展,侵入性越来越小。我们开发了一种新的血液引导附件,用于微创植入,将心脏内的血液通过经主动脉流出重新定向到升主动脉。方法:10头健康母猪(德国长白猪,104.4±13.0 kg)在左心室辅助装置植入前后行心外膜超声心动图检查。在植入前后评估心脏几何形状、主动脉瓣功能和流出口定位。结果:心外膜超声心动图显示装置植入后双心室有充分的卸荷。舒张末期和收缩末期左心室直径分别下降16%和20%。左心房和右心房直径较小,分别为22%和25%,显示逆行卸载。在基线时,一只动物出现轻度主动脉反流,在机械支持下没有变化,而一只动物出现轻度新生功能不全。流出部移植物要么位于主动脉瓣内(n = 3),要么位于两个瓣尖之间。结论:带有附件的左心室辅助装置允许充分的心室卸载,保留双心室功能。尽管只有30%的病例流出体移植物在主动脉瓣内处于中心位置,但在急性情况下没有发现相关的主动脉反流。为了长期分析结果,需要在更大的样本中进行长期测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信