{"title":"Dimensional Stability and Weight Change of Orthodontic Clear Aligners Exposed to Hot and Cold Beverages: An In Vitro Study","authors":"Garmyan Yar Ahmed,&nbsp;Hadi Ismail","doi":"10.1155/adv/6251993","DOIUrl":null,"url":null,"abstract":"<p>This study aims to find the influence of hot and cold beverages on single-layered (SL) and multilayered (ML) clear aligners in terms of dimensional stability, weight variations, and chemical characteristics by using attenuated total reflectance fourier-transform infrared (ATR-FTIR) spectroscopy and X-ray diffraction (XRD) technique. One hundred clear aligners were thermoformed, 50 per material, and subdivided into five groups (10 per group). The groups were coffee at 55°C, distilled water at 55°C, cola at 5°C, distilled water at 5°C, and distilled water at 37°C. The aligners were scanned and weighed along with chemical characterization, then immersed in the solutions for 45 min daily for 14 days. After finishing the immersion period, they were rescanned and weighed, and chemical characterization analyses were taken. Scans were superimposed by GeoMagic Control X software. The root mean square (RMS) of the deviations was used to compare dimensional changes. The results revealed significantly higher RMS in distilled water at 55°C and coffee than in other groups. The SL showed higher RMS values than ML groups; all aligners gained weight, and the rate was higher for hot solutions. In conclusion, hot beverages negatively impact clear aligners’ dimensional stability, and patients should avoid drinking them while wearing their aligners.</p>","PeriodicalId":7372,"journal":{"name":"Advances in Polymer Technology","volume":"2025 1","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2025-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/adv/6251993","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Polymer Technology","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/adv/6251993","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study aims to find the influence of hot and cold beverages on single-layered (SL) and multilayered (ML) clear aligners in terms of dimensional stability, weight variations, and chemical characteristics by using attenuated total reflectance fourier-transform infrared (ATR-FTIR) spectroscopy and X-ray diffraction (XRD) technique. One hundred clear aligners were thermoformed, 50 per material, and subdivided into five groups (10 per group). The groups were coffee at 55°C, distilled water at 55°C, cola at 5°C, distilled water at 5°C, and distilled water at 37°C. The aligners were scanned and weighed along with chemical characterization, then immersed in the solutions for 45 min daily for 14 days. After finishing the immersion period, they were rescanned and weighed, and chemical characterization analyses were taken. Scans were superimposed by GeoMagic Control X software. The root mean square (RMS) of the deviations was used to compare dimensional changes. The results revealed significantly higher RMS in distilled water at 55°C and coffee than in other groups. The SL showed higher RMS values than ML groups; all aligners gained weight, and the rate was higher for hot solutions. In conclusion, hot beverages negatively impact clear aligners’ dimensional stability, and patients should avoid drinking them while wearing their aligners.

Abstract Image

正畸透明矫正器在冷热饮料中的尺寸稳定性和重量变化:体外研究
本研究旨在通过衰减全反射傅里叶变换红外(ATR-FTIR)光谱和x射线衍射(XRD)技术,研究冷热饮料对单层(SL)和多层(ML)透明对准剂在尺寸稳定性、重量变化和化学特性方面的影响。100个透明对准器热成型,每种材料50个,并细分为五组(每组10个)。这些组分别是55°C的咖啡、55°C的蒸馏水、5°C的可乐、5°C的蒸馏水和37°C的蒸馏水。对校准器进行扫描和称重,并进行化学表征,然后每天浸泡在溶液中45分钟,持续14天。浸泡结束后,重新扫描称重,并进行化学表征分析。扫描结果由GeoMagic Control X软件叠加。采用偏差的均方根(RMS)比较量纲变化。结果显示,55°C蒸馏水和咖啡中的RMS明显高于其他组。SL组RMS值高于ML组;所有对准器都增加了重量,热溶液的速率更高。综上所述,热饮会对牙齿矫正器的尺寸稳定性产生负面影响,患者在佩戴牙齿矫正器时应避免饮用热饮。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Advances in Polymer Technology
Advances in Polymer Technology 工程技术-高分子科学
CiteScore
5.50
自引率
0.00%
发文量
70
审稿时长
9 months
期刊介绍: Advances in Polymer Technology publishes articles reporting important developments in polymeric materials, their manufacture and processing, and polymer product design, as well as those considering the economic and environmental impacts of polymer technology. The journal primarily caters to researchers, technologists, engineers, consultants, and production personnel.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书