Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter.

IF 1.2 4区 综合性期刊 Q3 MULTIDISCIPLINARY SCIENCES
Suqi Xian, Yifan Tang, Peng Ji, Hongsheng Bi, Qingbao Wang, Xiaofan Wang, Li Li
{"title":"Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter.","authors":"Suqi Xian, Yifan Tang, Peng Ji, Hongsheng Bi, Qingbao Wang, Xiaofan Wang, Li Li","doi":"10.3791/68422","DOIUrl":null,"url":null,"abstract":"<p><p>The aim is to evaluate the agreement and accuracy of refraction using a binocular wavefront optometer with the autorefractor and phoropter. To do this, 1 month after corneal refractive surgery, the right eyes of 125 subjects were enrolled in this cross-sectional study. Objective and subjective refractions were measured using a binocular wavefront optometer, an autorefractor, and a phoropter in a noncycloplegic condition. The differences and agreement of refractive data were analyzed using the Wilcoxon signed-rank test and Bland-Altman plots. The differences between sphere (Z=-0.872, p=0.38), J0 (Z=-0.065, p=0.95), J45 (Z=-1.199, p=0.23), and SE (Z=-1.316, p=0.19), objectively detected by binocular wavefront optometer and autorefractor, were not statistically significant. The differences between J0 (Z=-0.533, p=0.59), J45 (Z=-0.724, p=0.47), and SE (Z=-0.933, p=0.35), subjectively detected by binocular wavefront optometer and phoropter, were not statistically significant, whereas sphere (Z=-3.699, p<0.0001) had statistically significant differences. The Bland-Altman plots showed agreement between binocular wavefront optometer objective refraction and autorefractor in sphere (95% LoA: -1.00 D to 0.89 D), J0 (95% LoA: -0.47 D to 0.47 D), J45 (95% LoA: -0.55 D to 0.58 D), and SE (95% LoA: -0.89 D to 0.96 D). The Bland-Altman plots also showed agreement between binocular wavefront optometer subjective refraction and phoropter in sphere (95% LoA: -0.59 D to 0.82 D), J0 (95% LoA: -0.47 D to 0.43 D), J45 (95% LoA: -0.47 D to 0.43 D), and SE (95% LoA: -0.66 D to 0.74 D). Conclusively, the binocular wavefront optometer is an effective instrument, demonstrating good agreement between its objective and subjective refraction results and those obtained from autorefractor and phoropter, its smaller refractive intervals presenting a high accuracy in refractive error detection.</p>","PeriodicalId":48787,"journal":{"name":"Jove-Journal of Visualized Experiments","volume":" 223","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2025-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jove-Journal of Visualized Experiments","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3791/68422","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The aim is to evaluate the agreement and accuracy of refraction using a binocular wavefront optometer with the autorefractor and phoropter. To do this, 1 month after corneal refractive surgery, the right eyes of 125 subjects were enrolled in this cross-sectional study. Objective and subjective refractions were measured using a binocular wavefront optometer, an autorefractor, and a phoropter in a noncycloplegic condition. The differences and agreement of refractive data were analyzed using the Wilcoxon signed-rank test and Bland-Altman plots. The differences between sphere (Z=-0.872, p=0.38), J0 (Z=-0.065, p=0.95), J45 (Z=-1.199, p=0.23), and SE (Z=-1.316, p=0.19), objectively detected by binocular wavefront optometer and autorefractor, were not statistically significant. The differences between J0 (Z=-0.533, p=0.59), J45 (Z=-0.724, p=0.47), and SE (Z=-0.933, p=0.35), subjectively detected by binocular wavefront optometer and phoropter, were not statistically significant, whereas sphere (Z=-3.699, p<0.0001) had statistically significant differences. The Bland-Altman plots showed agreement between binocular wavefront optometer objective refraction and autorefractor in sphere (95% LoA: -1.00 D to 0.89 D), J0 (95% LoA: -0.47 D to 0.47 D), J45 (95% LoA: -0.55 D to 0.58 D), and SE (95% LoA: -0.89 D to 0.96 D). The Bland-Altman plots also showed agreement between binocular wavefront optometer subjective refraction and phoropter in sphere (95% LoA: -0.59 D to 0.82 D), J0 (95% LoA: -0.47 D to 0.43 D), J45 (95% LoA: -0.47 D to 0.43 D), and SE (95% LoA: -0.66 D to 0.74 D). Conclusively, the binocular wavefront optometer is an effective instrument, demonstrating good agreement between its objective and subjective refraction results and those obtained from autorefractor and phoropter, its smaller refractive intervals presenting a high accuracy in refractive error detection.

带自折射镜的双目波前视光计与光镜的一致性和精度比较。
目的是评价双目镜波前验光仪的折射一致性和折射精度。为此,在角膜屈光手术1个月后,125名受试者的右眼被纳入这项横断面研究。在非睫状体瘫痪的情况下,使用双目波前验光仪、自折射仪和光镜测量客观和主观折射。使用Wilcoxon符号秩检验和Bland-Altman图分析折光数据的差异和一致性。双眼波前验光仪和自折射镜客观检测的球(Z=-0.872, p=0.38)、J0 (Z=-0.065, p=0.95)、J45 (Z=-1.199, p=0.23)、SE (Z=-1.316, p=0.19)差异无统计学意义。J0 (Z=-0.533, p=0.59)、J45 (Z=-0.724, p=0.47)和SE (Z=-0.933, p=0.35)在双眼波前验光仪和光镜主观上的差异无统计学意义
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Jove-Journal of Visualized Experiments
Jove-Journal of Visualized Experiments MULTIDISCIPLINARY SCIENCES-
CiteScore
2.10
自引率
0.00%
发文量
992
期刊介绍: JoVE, the Journal of Visualized Experiments, is the world''s first peer reviewed scientific video journal. Established in 2006, JoVE is devoted to publishing scientific research in a visual format to help researchers overcome two of the biggest challenges facing the scientific research community today; poor reproducibility and the time and labor intensive nature of learning new experimental techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信