{"title":"Laparoscopic sacrocolpopexy with mesh fixation: a randomized trial comparing synthetic cyanoacrylate glue to sutures.","authors":"Gery Lamblin, Graziella Moufawad, Cécile Becque, Chloé Miguet, Stéphanie Moret, Sophie Warembourg, Erdogan Nohuz, Charles-André Philip","doi":"10.1007/s00345-025-05885-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare laparoscopic sacrocolpopexy using synthetic glue for mesh fixation to laparoscopic suturing in the treatment of pelvic organ prolapse.</p><p><strong>Materials and methods: </strong>This prospective randomized controlled trial included 54 patients with stage III or IV pelvic organ prolapse who underwent surgical correction and were allocated to two groups: a glue group which underwent laparoscopic sacrocolpopexy using synthetic cyanoacrylate glue for mesh fixation and a sutures group which underwent the same procedure using suturing for mesh fixation. Operative time, success rate, and perioperative complications were compared between the two groups. Patients were followed up at 1, 12, and 24 months postoperatively.</p><p><strong>Results: </strong>The median operative time was 108.8 min [83.2-155.6] in the glue group and 111.4 min [90.2-186.2] in the sutures group, without significant difference between the groups. However, the time required for anterior mesh fixation was significantly lower in the glue group compared to the sutures group (4.6 min [0.5-29.6] vs. 25.4 min [1.7-44.7], p = 0.0001). The anatomical success rates ranged from 100 to 92.6% at 1 month postoperatively, and from 88.2 to 73.7% at 24 months in the glue and sutures groups, respectively, without statistically significant difference.</p><p><strong>Conclusions: </strong>The use of synthetic glue in laparoscopic sacrocolpopexy is a safe and effective alternative to suturing. However, larger studies with extended follow-up are required to further assess long-term efficacy and complication rates.</p>","PeriodicalId":23954,"journal":{"name":"World Journal of Urology","volume":"43 1","pages":"598"},"PeriodicalIF":2.9000,"publicationDate":"2025-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00345-025-05885-x","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare laparoscopic sacrocolpopexy using synthetic glue for mesh fixation to laparoscopic suturing in the treatment of pelvic organ prolapse.

Materials and methods: This prospective randomized controlled trial included 54 patients with stage III or IV pelvic organ prolapse who underwent surgical correction and were allocated to two groups: a glue group which underwent laparoscopic sacrocolpopexy using synthetic cyanoacrylate glue for mesh fixation and a sutures group which underwent the same procedure using suturing for mesh fixation. Operative time, success rate, and perioperative complications were compared between the two groups. Patients were followed up at 1, 12, and 24 months postoperatively.

Results: The median operative time was 108.8 min [83.2-155.6] in the glue group and 111.4 min [90.2-186.2] in the sutures group, without significant difference between the groups. However, the time required for anterior mesh fixation was significantly lower in the glue group compared to the sutures group (4.6 min [0.5-29.6] vs. 25.4 min [1.7-44.7], p = 0.0001). The anatomical success rates ranged from 100 to 92.6% at 1 month postoperatively, and from 88.2 to 73.7% at 24 months in the glue and sutures groups, respectively, without statistically significant difference.

Conclusions: The use of synthetic glue in laparoscopic sacrocolpopexy is a safe and effective alternative to suturing. However, larger studies with extended follow-up are required to further assess long-term efficacy and complication rates.

腹腔镜骶colpop固定术与网片固定:一项比较合成氰基丙烯酸酯胶与缝合线的随机试验。
目的:比较腹腔镜骶colpop固定术应用合成胶网固定与腹腔镜缝合治疗盆腔脏器脱垂的疗效。材料和方法:本前瞻性随机对照试验纳入54例行手术矫正的III期或IV期盆腔器官脱垂患者,分为两组:胶水组行腹腔镜骶colpop固定术,使用合成氰基丙烯酸酯胶水进行补片固定;缝合组采用相同的方法,使用缝线进行补片固定。比较两组手术时间、成功率及围手术期并发症。分别于术后1、12、24个月进行随访。结果:胶组中位手术时间为108.8 min[83.2 ~ 155.6],缝线组中位手术时间为111.4 min[90.2 ~ 186.2],两组间差异无统计学意义。然而,与缝线组相比,胶水组前路补片固定所需时间明显较低(4.6 min [0.5-29.6] vs. 25.4 min [1.7-44.7], p = 0.0001)。胶组和缝线组术后1个月解剖成功率分别为100 ~ 92.6%,24个月解剖成功率分别为88.2 ~ 73.7%,差异无统计学意义。结论:合成胶用于腹腔镜骶骶固定术是一种安全、有效的替代缝合方法。然而,需要更大规模的长期随访研究来进一步评估长期疗效和并发症发生率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
World Journal of Urology
World Journal of Urology 医学-泌尿学与肾脏学
CiteScore
6.80
自引率
8.80%
发文量
317
审稿时长
4-8 weeks
期刊介绍: The WORLD JOURNAL OF UROLOGY conveys regularly the essential results of urological research and their practical and clinical relevance to a broad audience of urologists in research and clinical practice. In order to guarantee a balanced program, articles are published to reflect the developments in all fields of urology on an internationally advanced level. Each issue treats a main topic in review articles of invited international experts. Free papers are unrelated articles to the main topic.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信