{"title":"Assessment of removal torque values of anodized abutment screws at different voltages: an in vitro study.","authors":"Yıldız Arslan, Hasan Önder Gümüş, Emine Dilara Çolpak","doi":"10.1186/s12903-025-06816-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of this in vitro study is to compare the removal torque values of abutment screws anodized with different voltage values.</p><p><strong>Methods: </strong>The abutment screws were divided into 6 groups according to their surface treatment: non-treated (C) Control group (n = 24), acid etched only (A) Acidic uncolored (n = 24), anodized with 27 V and painted blue (B) Blue (n = 24), after acid etching anodized with 27 V and painted blue (AB) Acidic Blue (n = 24), anodized with 55 V and painted yellow (Y) Yellow (n = 24) and after acid etching anodized with 55 V and painted yellow (AY) Acidic Yellow (n = 24). 144 bone-level implants to which the abutments will be attached are embedded in auto polymerized acrylic resin. All abutment screws were tightened to 30 Ncm on the digital torque meter. The removal torque values of abutment screws were obtained, and A three-way ANOVA was performed for statistical analysis, and Tukey's test was used for multiple comparisons.</p><p><strong>Results: </strong>Decreased removal torque values were observed in all groups after thermomechanical cycling. Only application anodization process to abutment screws reduces removal torques of the screws. In case of acid etching before anodization, it was observed that removal torques increased. Applying only acid etching process to abutment screws reduces removal torques of the screws. However, when the screws are anodized after acid etching, it has been observed that removal torques increase.</p><p><strong>Conclusion: </strong>It was observed that anodizing the abutment screws with different voltages did not make a significant change in the removal torques.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"1532"},"PeriodicalIF":3.1000,"publicationDate":"2025-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12498437/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-06816-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The purpose of this in vitro study is to compare the removal torque values of abutment screws anodized with different voltage values.

Methods: The abutment screws were divided into 6 groups according to their surface treatment: non-treated (C) Control group (n = 24), acid etched only (A) Acidic uncolored (n = 24), anodized with 27 V and painted blue (B) Blue (n = 24), after acid etching anodized with 27 V and painted blue (AB) Acidic Blue (n = 24), anodized with 55 V and painted yellow (Y) Yellow (n = 24) and after acid etching anodized with 55 V and painted yellow (AY) Acidic Yellow (n = 24). 144 bone-level implants to which the abutments will be attached are embedded in auto polymerized acrylic resin. All abutment screws were tightened to 30 Ncm on the digital torque meter. The removal torque values of abutment screws were obtained, and A three-way ANOVA was performed for statistical analysis, and Tukey's test was used for multiple comparisons.

Results: Decreased removal torque values were observed in all groups after thermomechanical cycling. Only application anodization process to abutment screws reduces removal torques of the screws. In case of acid etching before anodization, it was observed that removal torques increased. Applying only acid etching process to abutment screws reduces removal torques of the screws. However, when the screws are anodized after acid etching, it has been observed that removal torques increase.

Conclusion: It was observed that anodizing the abutment screws with different voltages did not make a significant change in the removal torques.

Abstract Image

Abstract Image

Abstract Image

不同电压下阳极氧化基牙螺钉去除扭矩值的体外研究。
背景:本体外研究的目的是比较不同电压值氧化处理的基牙螺钉的去除扭矩值。方法:桥台螺丝被分成6组根据他们的表面处理:摘要(C)对照组(n = 24),酸蚀刻只(A)酸性本色的(n = 24),阳极氧化膜与27 V和漆成蓝色(B)蓝色(n = 24),与27 V和酸腐蚀阳极化处理后涂成蓝色(AB)酸性蓝(n = 24),阳极氧化膜与55 V和漆成黄色(Y)黄(n = 24)和酸腐蚀阳极氧化后55 V和漆成黄色(AY)酸性黄(n = 24)。144个骨水平种植体将被嵌入自动聚合丙烯酸树脂中,这些种植体将被附着在基台上。在数字扭矩计上将所有基台螺钉拧紧至30 Ncm。获得基牙螺钉的移除扭矩值,采用三向方差分析进行统计分析,多重比较采用Tukey检验。结果:热机械循环后,各组脱模扭矩值均有所降低。只有对基台螺钉进行阳极氧化处理才能减少螺钉的拆卸扭矩。如果在阳极氧化前进行酸蚀,则观察到去除扭矩增加。仅对基牙螺钉进行酸蚀处理可减少螺钉的移除力矩。然而,当在酸蚀后对螺钉进行阳极氧化时,观察到去除扭矩增加。结论:观察到不同电压对基牙螺钉进行阳极氧化处理后,其去除力矩无明显变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信