Simulation of medium-temperature cesium heat pipes using the pressure-modified Capillary Wick model

IF 5.8 2区 工程技术 Q1 ENGINEERING, MECHANICAL
Yinghua Ma , Guoqing Huang , Hongxia Chen , Li Jia , Xiaodong Wang
{"title":"Simulation of medium-temperature cesium heat pipes using the pressure-modified Capillary Wick model","authors":"Yinghua Ma ,&nbsp;Guoqing Huang ,&nbsp;Hongxia Chen ,&nbsp;Li Jia ,&nbsp;Xiaodong Wang","doi":"10.1016/j.ijheatmasstransfer.2025.127892","DOIUrl":null,"url":null,"abstract":"<div><div>Accurately simulating the flow of the working fluid within capillary wicks and the corresponding circulation dynamics in heat pipes presents a significant challenge. In this study, a pressure-modified Capillary Wick model is proposed based on molecular dynamics simulations. By customizing the momentum source term to generate a high-pressure region adjacent to the wall, the capillary pumping effect is precisely simulated. Concurrently, more physically consistent distributions of pressure and saturation temperature are achieved, with the nucleation site migrating from the inner wall of capillary wick structure to its outer surface. These improvements suppress velocity fluctuations of the condensate film and eliminate the unphysical entrainment limit phenomenon at low heating powers, along with the associated overheating of the evaporator. In comparison with the Wall Adhesion model, the vapor dryness fraction of the condenser increases from 0.436 to 0.609. Furthermore, the maximum temperature deviation of the evaporator decreases from 121.46 K to 20.38 K with a 83.22 % reduction, while the average temperature deviation of the evaporator decreases from 40.07 K to 9.08 K, with the relative error decreasing from 5.78 % to 1.31 %. Correspondingly, the overall thermal resistance of the heat pipe is reduced from 3.818 K·kW<sup>-1</sup> to 1.941 K·kW<sup>-1</sup>, representing a 49.14 % reduction and thereby bringing the simulation results into closer agreement with experimental data.</div></div>","PeriodicalId":336,"journal":{"name":"International Journal of Heat and Mass Transfer","volume":"255 ","pages":"Article 127892"},"PeriodicalIF":5.8000,"publicationDate":"2025-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Heat and Mass Transfer","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S001793102501227X","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Accurately simulating the flow of the working fluid within capillary wicks and the corresponding circulation dynamics in heat pipes presents a significant challenge. In this study, a pressure-modified Capillary Wick model is proposed based on molecular dynamics simulations. By customizing the momentum source term to generate a high-pressure region adjacent to the wall, the capillary pumping effect is precisely simulated. Concurrently, more physically consistent distributions of pressure and saturation temperature are achieved, with the nucleation site migrating from the inner wall of capillary wick structure to its outer surface. These improvements suppress velocity fluctuations of the condensate film and eliminate the unphysical entrainment limit phenomenon at low heating powers, along with the associated overheating of the evaporator. In comparison with the Wall Adhesion model, the vapor dryness fraction of the condenser increases from 0.436 to 0.609. Furthermore, the maximum temperature deviation of the evaporator decreases from 121.46 K to 20.38 K with a 83.22 % reduction, while the average temperature deviation of the evaporator decreases from 40.07 K to 9.08 K, with the relative error decreasing from 5.78 % to 1.31 %. Correspondingly, the overall thermal resistance of the heat pipe is reduced from 3.818 K·kW-1 to 1.941 K·kW-1, representing a 49.14 % reduction and thereby bringing the simulation results into closer agreement with experimental data.
用压力修正毛细管芯模型模拟中温铯热管
准确模拟毛细管芯内工作流体的流动及其在热管中的循环动力学是一项重大挑战。本文提出了一种基于分子动力学模拟的压力修正毛细管芯模型。通过定制动量源项在壁面附近产生高压区域,精确模拟了毛细管泵送效应。同时,压力和饱和温度的物理分布更加一致,成核位置从毛细管芯结构的内壁向外表面迁移。这些改进抑制了冷凝膜的速度波动,消除了在低加热功率下的非物理带吸极限现象,以及相关的蒸发器过热。与壁面粘附模型相比,冷凝器的蒸汽干燥分数从0.436增加到0.609。蒸发器的最大温度偏差从121.46 K减小到20.38 K,减小83.22%;蒸发器的平均温度偏差从40.07 K减小到9.08 K,相对误差从5.78%减小到1.31%。相应的,热管总热阻由3.818 K·K -1减小到1.941 K·K -1,减小了49.14%,使模拟结果与实验数据更加吻合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.30
自引率
13.50%
发文量
1319
审稿时长
41 days
期刊介绍: International Journal of Heat and Mass Transfer is the vehicle for the exchange of basic ideas in heat and mass transfer between research workers and engineers throughout the world. It focuses on both analytical and experimental research, with an emphasis on contributions which increase the basic understanding of transfer processes and their application to engineering problems. Topics include: -New methods of measuring and/or correlating transport-property data -Energy engineering -Environmental applications of heat and/or mass transfer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信