Dual-temperature air circulation and preventing moisture intake to solve frosting issue in low-temperature refrigerators

IF 6.4 2区 工程技术 Q1 MECHANICS
Guixiang He , Guoqiang Liu , Tianyang Zhao , Gang Yan , Chenyue Wang , Yue Li , Cainan Zhou
{"title":"Dual-temperature air circulation and preventing moisture intake to solve frosting issue in low-temperature refrigerators","authors":"Guixiang He ,&nbsp;Guoqiang Liu ,&nbsp;Tianyang Zhao ,&nbsp;Gang Yan ,&nbsp;Chenyue Wang ,&nbsp;Yue Li ,&nbsp;Cainan Zhou","doi":"10.1016/j.icheatmasstransfer.2025.109728","DOIUrl":null,"url":null,"abstract":"<div><div>As temperature decreases, severe frosting on the cabinet walls of refrigerators affects normal use. Frosting in low-temperature refrigerators is closely related to moisture transfer. This study focuses on a refrigerator set at −40 °C to −18 °C. Firstly, the frosting phenomena and moisture transfer processes at −40 °C and − 18 °C were compared. Then, the tracer gas method was employed to quantify the moisture intake and its distribution at −40 °C. Results show that 64.3 % of the moisture enters during the door opening process and 65.7 % of the entering moisture deposits as frost on the cabinet walls, while only 34.3 % transfers to the evaporator for centralized melting. Finally, two methods are proposed to solve the frosting issue. The first is to activate the dual-temperature air circulation for 1 h after each door opening-closing operation, which can accelerate the moisture transfer to the evaporator. Experiments confirm that this method can redistribute the frosting ratio on the walls from 65.7 % to 36.0 % and maintain door opening force below 70 N. The second is to keep the fan on during each door opening process to prevent moisture intake. The computational fluid dynamics (CFD) simulation results show that this method can reduce moisture intake by 28.6 %. This study provides two novel methods for solving the frosting issue of low-temperature refrigerators, which can improve their reliability.</div></div>","PeriodicalId":332,"journal":{"name":"International Communications in Heat and Mass Transfer","volume":"169 ","pages":"Article 109728"},"PeriodicalIF":6.4000,"publicationDate":"2025-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Communications in Heat and Mass Transfer","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0735193325011546","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MECHANICS","Score":null,"Total":0}
引用次数: 0

Abstract

As temperature decreases, severe frosting on the cabinet walls of refrigerators affects normal use. Frosting in low-temperature refrigerators is closely related to moisture transfer. This study focuses on a refrigerator set at −40 °C to −18 °C. Firstly, the frosting phenomena and moisture transfer processes at −40 °C and − 18 °C were compared. Then, the tracer gas method was employed to quantify the moisture intake and its distribution at −40 °C. Results show that 64.3 % of the moisture enters during the door opening process and 65.7 % of the entering moisture deposits as frost on the cabinet walls, while only 34.3 % transfers to the evaporator for centralized melting. Finally, two methods are proposed to solve the frosting issue. The first is to activate the dual-temperature air circulation for 1 h after each door opening-closing operation, which can accelerate the moisture transfer to the evaporator. Experiments confirm that this method can redistribute the frosting ratio on the walls from 65.7 % to 36.0 % and maintain door opening force below 70 N. The second is to keep the fan on during each door opening process to prevent moisture intake. The computational fluid dynamics (CFD) simulation results show that this method can reduce moisture intake by 28.6 %. This study provides two novel methods for solving the frosting issue of low-temperature refrigerators, which can improve their reliability.
双温空气循环,防止吸湿,解决低温冰箱结霜问题
随着温度的降低,冰箱柜壁结霜严重,影响正常使用。低温冰箱结霜与水分传递密切相关。本研究的重点是设置在- 40°C至- 18°C的冰箱。首先,比较了- 40°C和- 18°C下的结霜现象和水分传递过程。然后,采用示踪气体法对- 40°C下的吸湿量及其分布进行量化。结果表明:64.3%的水分是在柜门开启过程中进入的,65.7%的水分以结霜的形式沉积在柜壁上,只有34.3%的水分转移到蒸发器进行集中融化。最后,提出了两种解决结霜问题的方法。一是每次开门关门操作后激活双温空气循环1h,可以加速水分向蒸发器的传递。实验证实,该方法可以将墙体上的结霜率从65.7%重新分配到36.0%,使开门力保持在70 n以下。二是每次开门过程中保持风机开着,防止吸湿。计算流体力学(CFD)仿真结果表明,该方法可使吸湿量减少28.6%。本研究提供了两种解决低温冰箱结霜问题的新方法,提高了低温冰箱的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
11.00
自引率
10.00%
发文量
648
审稿时长
32 days
期刊介绍: International Communications in Heat and Mass Transfer serves as a world forum for the rapid dissemination of new ideas, new measurement techniques, preliminary findings of ongoing investigations, discussions, and criticisms in the field of heat and mass transfer. Two types of manuscript will be considered for publication: communications (short reports of new work or discussions of work which has already been published) and summaries (abstracts of reports, theses or manuscripts which are too long for publication in full). Together with its companion publication, International Journal of Heat and Mass Transfer, with which it shares the same Board of Editors, this journal is read by research workers and engineers throughout the world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信