{"title":"In situ gamma ray spectrometry for environmental monitoring: Full Spectrum Analysis and dose assessment","authors":"Thi Yen Hong Huynh,&nbsp;Huu Ngan Thy Truong,&nbsp;Thanh Thao Tran,&nbsp;Ngoc Ba Vu","doi":"10.1007/s10967-025-10359-w","DOIUrl":null,"url":null,"abstract":"<div><p>This study developed and validated an in situ Full Spectrum Analysis (FSA) method using a NaI(Tl) detector for environmental radiation monitoring in Ho Chi Minh City. Mean activity concentrations of <sup>238</sup>U (21.8 Bq kg⁻<sup>1</sup>) and <sup>232</sup>Th (33.8 Bq kg⁻<sup>1</sup>) were near or below global averages, while <sup>40</sup>K (57.8 Bq kg⁻<sup>1</sup>) was notably depleted. Anthropogenic <sup>137</sup>Cs was negligible. Derived radiological hazard indices, including an average outdoor annual effective dose of 0.04 mSv y⁻<sup>1</sup>, were well within international safety limits. The findings confirm the method’s utility and indicate a low terrestrial gamma radiation risk in the surveyed urban areas.</p></div>","PeriodicalId":661,"journal":{"name":"Journal of Radioanalytical and Nuclear Chemistry","volume":"334 9","pages":"6267 - 6280"},"PeriodicalIF":1.6000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radioanalytical and Nuclear Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10967-025-10359-w","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study developed and validated an in situ Full Spectrum Analysis (FSA) method using a NaI(Tl) detector for environmental radiation monitoring in Ho Chi Minh City. Mean activity concentrations of 238U (21.8 Bq kg⁻1) and 232Th (33.8 Bq kg⁻1) were near or below global averages, while 40K (57.8 Bq kg⁻1) was notably depleted. Anthropogenic 137Cs was negligible. Derived radiological hazard indices, including an average outdoor annual effective dose of 0.04 mSv y⁻1, were well within international safety limits. The findings confirm the method’s utility and indicate a low terrestrial gamma radiation risk in the surveyed urban areas.

环境监测用现场伽马射线能谱法:全谱分析和剂量评估
本研究开发并验证了一种使用NaI(Tl)探测器的现场全谱分析(FSA)方法,用于胡志明市的环境辐射监测。238U (21.8 Bq kg - 1)和232Th (33.8 Bq kg - 1)的平均活度浓度接近或低于全球平均水平,而40K (57.8 Bq kg - 1)的活度浓度明显减少。人为的137Cs可以忽略不计。衍生的辐射危害指数,包括室外年平均有效剂量0.04毫西弗(毒血症),完全在国际安全限度之内。研究结果证实了该方法的实用性,并表明在被调查的城市地区地面伽马辐射风险较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
18.80%
发文量
504
审稿时长
2.2 months
期刊介绍: An international periodical publishing original papers, letters, review papers and short communications on nuclear chemistry. The subjects covered include: Nuclear chemistry, Radiochemistry, Radiation chemistry, Radiobiological chemistry, Environmental radiochemistry, Production and control of radioisotopes and labelled compounds, Nuclear power plant chemistry, Nuclear fuel chemistry, Radioanalytical chemistry, Radiation detection and measurement, Nuclear instrumentation and automation, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信