Comparison of Keratometric Changes After Ab Interno Gel Stent Implantation, Glaucoma Drainage Devices and Trabeculectomy.

Clinical ophthalmology (Auckland, N.Z.) Pub Date : 2025-09-26 eCollection Date: 2025-01-01 DOI:10.2147/OPTH.S536897
Kenan Bachour, Dominique Geoffrion, Guillaume A Mullie, Younes Agoumi, Georges M Durr
{"title":"Comparison of Keratometric Changes After Ab Interno Gel Stent Implantation, Glaucoma Drainage Devices and Trabeculectomy.","authors":"Kenan Bachour, Dominique Geoffrion, Guillaume A Mullie, Younes Agoumi, Georges M Durr","doi":"10.2147/OPTH.S536897","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare postoperative keratometric changes and surgically induced astigmatism (SIA) after Ab Interno Gel Stent Implantation (XEN), glaucoma drainage device (GDD), and trabeculectomy (TRAB). GDDs included Ahmed glaucoma valve (AGV) and Baerveldt glaucoma implant (BGI).</p><p><strong>Design: </strong>Prospective, interventional, longitudinal study.</p><p><strong>Participants and methods: </strong>Fifty-one eyes with glaucoma undergoing glaucoma filtering surgery were recruited between November 2020 and May 2023. The groups consisted of 19 XEN implants (37%), 21 GDDs (41%) (2 AGVs, 19 BGIs), and 11 trabeculectomies (22%). Primary outcomes were SIA at 12 months postoperatively, measured by Pentacam (Scheimpflug imaging) and OPD-scan (topography). The arithmetic mean of SIA (M-SIA) and the centroid of SIA (C-SIA) were determined using vector analysis. Secondary outcomes included BCVA, IOP, number of meds, and complications.</p><p><strong>Results: </strong>At 12 months, C-SIA measured by tomography was similar across all groups (0.3 ± 1.0 D for XENs and GDDs and 0.4 ± 1.0 D for TRAB). Topography measurements demonstrated a C-SIA of 0.2 ± 0.9 D for XENs, 0.1 ± 0.9 D for GDD, and 0.6 ± 1.7 D for TRAB. TRAB showed a trend towards a higher proportion of eyes with >1D of astigmatism (73%) compared to the XEN (27%) and GDD groups (48%, p = 0.159).</p><p><strong>Conclusion: </strong>SIA was similar across groups when measured by tomography, while topography measurements indicated a trend towards more SIA with TRAB. Mean cylinder values at 12 months were higher in the TRAB group.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":"19 ","pages":"3535-3545"},"PeriodicalIF":0.0000,"publicationDate":"2025-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12482951/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S536897","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare postoperative keratometric changes and surgically induced astigmatism (SIA) after Ab Interno Gel Stent Implantation (XEN), glaucoma drainage device (GDD), and trabeculectomy (TRAB). GDDs included Ahmed glaucoma valve (AGV) and Baerveldt glaucoma implant (BGI).

Design: Prospective, interventional, longitudinal study.

Participants and methods: Fifty-one eyes with glaucoma undergoing glaucoma filtering surgery were recruited between November 2020 and May 2023. The groups consisted of 19 XEN implants (37%), 21 GDDs (41%) (2 AGVs, 19 BGIs), and 11 trabeculectomies (22%). Primary outcomes were SIA at 12 months postoperatively, measured by Pentacam (Scheimpflug imaging) and OPD-scan (topography). The arithmetic mean of SIA (M-SIA) and the centroid of SIA (C-SIA) were determined using vector analysis. Secondary outcomes included BCVA, IOP, number of meds, and complications.

Results: At 12 months, C-SIA measured by tomography was similar across all groups (0.3 ± 1.0 D for XENs and GDDs and 0.4 ± 1.0 D for TRAB). Topography measurements demonstrated a C-SIA of 0.2 ± 0.9 D for XENs, 0.1 ± 0.9 D for GDD, and 0.6 ± 1.7 D for TRAB. TRAB showed a trend towards a higher proportion of eyes with >1D of astigmatism (73%) compared to the XEN (27%) and GDD groups (48%, p = 0.159).

Conclusion: SIA was similar across groups when measured by tomography, while topography measurements indicated a trend towards more SIA with TRAB. Mean cylinder values at 12 months were higher in the TRAB group.

Ab Interno凝胶支架植入术、青光眼引流装置和小梁切除术后角膜测量变化的比较。
目的:比较Ab Interno凝胶支架植入术(XEN)、青光眼引流装置(GDD)和小梁切除术(TRAB)术后角膜光度变化和手术性散光(SIA)。GDDs包括Ahmed青光眼瓣膜(AGV)和Baerveldt青光眼植入物(BGI)。设计:前瞻性、干预性、纵向研究。参与者和方法:在2020年11月至2023年5月期间招募了51只接受青光眼滤过手术的青光眼。这些组包括19例XEN植入物(37%),21例gdd(41%)(2例agv, 19例bgi)和11例小梁切除术(22%)。主要结果是术后12个月的SIA,由Pentacam (Scheimpflug成像)和opd扫描(地形)测量。采用矢量分析法测定SIA的算术平均值(M-SIA)和质心(C-SIA)。次要结局包括BCVA、IOP、用药次数和并发症。结果:12个月时,所有组的C-SIA测量结果相似(XENs和gdd为0.3±1.0 D, TRAB为0.4±1.0 D)。地形测量显示,XENs的C-SIA为0.2±0.9 D, GDD为0.1±0.9 D, TRAB为0.6±1.7 D。与XEN组(27%)和GDD组(48%,p = 0.159)相比,TRAB组的bb0 1D散光比例(73%)有更高的趋势。结论:层析成像测量的SIA在各组之间相似,而地形测量显示TRAB有更多SIA的趋势。TRAB组12个月时的平均柱面值更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信