{"title":"Home Tonometry Diurnal Intraocular Pressure Patterns, Patient Adherence, and Measurement Reliability in a Prospective Clinical Cohort.","authors":"Scott W Perkins, Julia H Joo, Kevin C Allan, Shalini Sood, Matthew James Schulgit, George A Markakis, Ang Li","doi":"10.2147/OPTH.S545165","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Assess patient adherence, diurnal intraocular pressure patterns, and correlation with in-office tonometry of home intraocular pressure monitoring (IOP).</p><p><strong>Patients and methods: </strong>In this prospective cohort study, 75 patients with open-angle disease (150 eyes) were recruited and loaned the iCare HOME2 tonometer (ICH2) after in-person training and instructed to take 6 measurements per day for 10 ± 4 days. Statistical analysis of adherence, diurnal IOP patterns, and correlation with in-office tonometry was conducted.</p><p><strong>Results: </strong>Most patients had good adherence (65% of patients took ≥ 6 measurements per day, median 7.4 measurements/day). However, adherence was poor for a notable minority of patients (19% of patients took less than 2 measurements per day). Patients with low adherence reported difficulty obtaining measurements and desire for more training with the ICH2 device. ICH2 identified diurnal patterns of IOP fluctuation: IOP varied significantly over the 24-hour day (p < 0.0001), and early morning peak IOP at 3 AM decreased significantly throughout the day to minimum mean IOP at 10 PM (p < 0.0001). IOP variance was significantly greater outside of clinic hours (p < 0.0001) and 36% of patients had maximum IOP outside of clinic hours. In-office IOP measurements had significant positive correlation to the closest ICH2 measurement obtained by the patient in time for both Goldman applanation (r<sup>2</sup> = 0.35, p < 0.0001) and iCare IC100 (r<sup>2</sup> = 0.48, p < 0.0001).</p><p><strong>Conclusion: </strong>ICH2 is clinically useable and effective for detecting out-of-office IOP spikes, diurnal IOP patterns, and IOP variation.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":"19 ","pages":"3547-3556"},"PeriodicalIF":0.0000,"publicationDate":"2025-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12482958/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S545165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Assess patient adherence, diurnal intraocular pressure patterns, and correlation with in-office tonometry of home intraocular pressure monitoring (IOP).

Patients and methods: In this prospective cohort study, 75 patients with open-angle disease (150 eyes) were recruited and loaned the iCare HOME2 tonometer (ICH2) after in-person training and instructed to take 6 measurements per day for 10 ± 4 days. Statistical analysis of adherence, diurnal IOP patterns, and correlation with in-office tonometry was conducted.

Results: Most patients had good adherence (65% of patients took ≥ 6 measurements per day, median 7.4 measurements/day). However, adherence was poor for a notable minority of patients (19% of patients took less than 2 measurements per day). Patients with low adherence reported difficulty obtaining measurements and desire for more training with the ICH2 device. ICH2 identified diurnal patterns of IOP fluctuation: IOP varied significantly over the 24-hour day (p < 0.0001), and early morning peak IOP at 3 AM decreased significantly throughout the day to minimum mean IOP at 10 PM (p < 0.0001). IOP variance was significantly greater outside of clinic hours (p < 0.0001) and 36% of patients had maximum IOP outside of clinic hours. In-office IOP measurements had significant positive correlation to the closest ICH2 measurement obtained by the patient in time for both Goldman applanation (r2 = 0.35, p < 0.0001) and iCare IC100 (r2 = 0.48, p < 0.0001).

Conclusion: ICH2 is clinically useable and effective for detecting out-of-office IOP spikes, diurnal IOP patterns, and IOP variation.

一项前瞻性临床队列的家庭血压计每日眼压模式、患者依从性和测量可靠性。
目的:评估患者的依从性,每日眼压模式,以及与家庭眼压监测(IOP)在办公室测压的相关性。患者和方法:在这项前瞻性队列研究中,招募了75例(150只眼)开角病患者,经现场培训后,使用iCare HOME2眼压计(ICH2),每天测量6次,持续10±4天。统计分析依从性、每日眼压模式以及与办公室眼压测量的相关性。结果:大多数患者具有良好的依从性(65%的患者每天≥6次测量,中位7.4次/天)。然而,少数患者的依从性较差(19%的患者每天测量少于2次)。依从性较低的患者报告难以获得测量结果,并希望使用ICH2设备进行更多训练。ICH2确定了IOP波动的日模式:IOP在24小时内变化显著(p < 0.0001),凌晨3点的清晨峰值IOP在全天内显著下降至晚上10点的最低平均IOP (p < 0.0001)。在门诊时间之外,IOP方差显著增大(p < 0.0001), 36%的患者在门诊时间之外的IOP最大。办公室内IOP测量值与患者及时获得的最接近的ic2测量值(r2 = 0.35, p < 0.0001)和iCare IC100测量值(r2 = 0.48, p < 0.0001)均有显著正相关。结论:ICH2在临床上可用于检测眼内压峰值、日眼内压模式和眼内压变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信