Thrombolytic Potential of “Hydrodynamic Cavitation on a Chip” Concept: Insights into Clot Degradation

IF 5.4 2区 工程技术 Q1 BIOCHEMICAL RESEARCH METHODS
Lab on a Chip Pub Date : 2025-10-02 DOI:10.1039/d5lc00482a
Abuzer Alp Yetisgin, Beyzanur Ozogul, Unal Akar, RABİA MERCİMEK, Seyedali Seyedmirzaei Sarraf, Tugrul Elverdi, Ehsan Amani, Dmitry Grishenkov, Ali Kosar, Morteza Ghorbani
{"title":"Thrombolytic Potential of “Hydrodynamic Cavitation on a Chip” Concept: Insights into Clot Degradation","authors":"Abuzer Alp Yetisgin, Beyzanur Ozogul, Unal Akar, RABİA MERCİMEK, Seyedali Seyedmirzaei Sarraf, Tugrul Elverdi, Ehsan Amani, Dmitry Grishenkov, Ali Kosar, Morteza Ghorbani","doi":"10.1039/d5lc00482a","DOIUrl":null,"url":null,"abstract":"Thrombolysis is essential for treating vascular conditions such as pulmonary embolism and deep vein thrombosis, yet current thrombolytic drug-based approaches have notable limitations in efficacy and safety. Hydrodynamic cavitation (HC) offers drug-free clot degradation through mechanical disruption. In this study, the effects of HC exposure on thrombolysis were investigated using Clot-on-a-Chip (CoC) platform. In this regard, the thrombolytic potential of HC exposure was evaluated by analyses involving hemolysis and fibrinolysis. Furthermore, the results were compared with Acoustic Cavitation (AC), a widely studied alternative. According to the obtained results, HC exposure (482 kPa, 120 s) resulted in 12.1% released hemoglobin and a 53.4% reduction in clot mass. In contrast, AC exposure (24 kHz, 50% amplitude, 30 s) led to a 1.3-fold greater mass reduction with 26.8% released hemoglobin, likely due to additional thermal effects. Morphological analyses revealed that HC treatment significantly reduced red blood cell density in a pressure- and time-dependent manner. Notably, HC treatment effectively eroded blood clots by hemolysis with slight fibrinolysis, whereas clot erosion in AC was primarily due to hemolysis. HC achieved thrombolysis comparable to or better than AC, offering a safer, more targeted strategy. The findings will advance mechanistic understanding of cavitation-induced clot degradation and support HC’s clinical potential for thrombosis treatment.","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":"17 1","pages":""},"PeriodicalIF":5.4000,"publicationDate":"2025-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1039/d5lc00482a","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Thrombolysis is essential for treating vascular conditions such as pulmonary embolism and deep vein thrombosis, yet current thrombolytic drug-based approaches have notable limitations in efficacy and safety. Hydrodynamic cavitation (HC) offers drug-free clot degradation through mechanical disruption. In this study, the effects of HC exposure on thrombolysis were investigated using Clot-on-a-Chip (CoC) platform. In this regard, the thrombolytic potential of HC exposure was evaluated by analyses involving hemolysis and fibrinolysis. Furthermore, the results were compared with Acoustic Cavitation (AC), a widely studied alternative. According to the obtained results, HC exposure (482 kPa, 120 s) resulted in 12.1% released hemoglobin and a 53.4% reduction in clot mass. In contrast, AC exposure (24 kHz, 50% amplitude, 30 s) led to a 1.3-fold greater mass reduction with 26.8% released hemoglobin, likely due to additional thermal effects. Morphological analyses revealed that HC treatment significantly reduced red blood cell density in a pressure- and time-dependent manner. Notably, HC treatment effectively eroded blood clots by hemolysis with slight fibrinolysis, whereas clot erosion in AC was primarily due to hemolysis. HC achieved thrombolysis comparable to or better than AC, offering a safer, more targeted strategy. The findings will advance mechanistic understanding of cavitation-induced clot degradation and support HC’s clinical potential for thrombosis treatment.
“芯片上的流体动力空化”概念的溶栓潜力:对凝块降解的见解
溶栓是治疗肺栓塞和深静脉血栓形成等血管疾病的必要手段,但目前基于药物的溶栓方法在有效性和安全性方面存在明显的局限性。流体动力空化(HC)通过机械破坏提供无药物的凝块降解。在本研究中,我们使用Clot-on-a-Chip (CoC)平台研究了HC暴露对溶栓的影响。在这方面,丙型肝炎暴露的溶栓潜力通过溶血和纤溶分析进行了评估。此外,还将结果与广泛研究的声空化(AC)进行了比较。根据得到的结果,HC暴露(482 kPa, 120 s)导致血红蛋白释放12.1%,血凝块减少53.4%。相比之下,交流暴露(24 kHz, 50%振幅,30 s)导致1.3倍的质量减少,26.8%的血红蛋白释放,可能是由于额外的热效应。形态学分析显示,HC治疗以压力和时间依赖的方式显著降低红细胞密度。值得注意的是,HC治疗通过溶血和轻微的纤维蛋白溶解有效地侵蚀了血凝块,而AC治疗的血凝块侵蚀主要是由于溶血。HC的溶栓效果与AC相当或更好,提供了更安全、更有针对性的策略。这些发现将促进对空化诱导的血块降解的机制理解,并支持HC在血栓治疗方面的临床潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信