{"title":"B-014 Analytical performance evaluation of the Abbott Vitamin assays on the Alinity ci system","authors":"Marvin Berman","doi":"10.1093/clinchem/hvaf086.412","DOIUrl":null,"url":null,"abstract":"Background Vitamins can be crucial for diagnosing and managing health conditions related to low or excessive intake and for monitoring the effectiveness of dietary changes or supplement strategies. Abbott provides an extensive menu of vitamin assays which aid in the diagnosis and management of many health conditions such as deficiency or excess. Assays such as Vitamin D, Vitamin B12 and Vitamin C are used to monitor bone health, neurological function and immune system function respectively. Thus, vitamins are valuable for disease risk assessment. Homocysteine is an amino acid that plays a crucial role in cell metabolism and its levels are closely linked to vitamins B12 and folate (vit B9) deficiencies. Recent guideline changes to Vitamin D (Endo Society 2024) and B12 (Nice 2024) support the need for accurate assay performance. The Alinity ci system is part of a unified family of systems that are engineered for flexibility, efficiency, and decreased system down time. The design is based on insights from customers, resulting in a number of benefits including a smaller footprint, improved workflow, and great throughput with up to 200 tests per hour. The objective of this study is to demonstrate the analytical performance of representative assays from the Vitamin Panel of the Alinity i system, which consists of assays that utilize photometric technology for the quantitative determination of analytes in human serum or plasma. Methods Key performance testing including precision, limit of quantitation (LoQ), endogenous interferents, linearity and method comparison were assessed per Clinical and Laboratory Standards Institute (CLSI) protocols. Precision was assessed by testing controls and panels twice per day for 20 days on 2 instruments. Sensitivity was determined with 3 reagent lots on 2 instruments. Endogenous compounds were evaluated at a minimum of one analyte concentration. Linearity was assessed using a minimum of 6 panels that spanned the measuring interval. Method comparison was performed by measuring a minimum of 100 specimens on Alinity and the comparator method. The assay measuring interval was defined by the range for which acceptable performance for bias, imprecision, and linearity was met. Results The observed results for precision were 4.1 to 9%. Alinity method comparison vs ARCHITECT demonstrated slopes of 0.95 to 1.04 with correlation coefficients of 0.96 to 1.00. All assays demonstrated equivalent sensitivities, linearity, interferents and measuring intervals to ARCHITECT. Conclusion Standardization of the Abbott assays ensures the assays meet current guidelines. The vitamin panel of assays on the Abbott Alinity i platform demonstrated acceptable performance for precision, sensitivity, interferents and linearity. Method comparison data showed equivalency with the on-market assays, which verified the performance of these products on the Alinity i system.","PeriodicalId":10690,"journal":{"name":"Clinical chemistry","volume":"19 1","pages":""},"PeriodicalIF":6.3000,"publicationDate":"2025-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/clinchem/hvaf086.412","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background Vitamins can be crucial for diagnosing and managing health conditions related to low or excessive intake and for monitoring the effectiveness of dietary changes or supplement strategies. Abbott provides an extensive menu of vitamin assays which aid in the diagnosis and management of many health conditions such as deficiency or excess. Assays such as Vitamin D, Vitamin B12 and Vitamin C are used to monitor bone health, neurological function and immune system function respectively. Thus, vitamins are valuable for disease risk assessment. Homocysteine is an amino acid that plays a crucial role in cell metabolism and its levels are closely linked to vitamins B12 and folate (vit B9) deficiencies. Recent guideline changes to Vitamin D (Endo Society 2024) and B12 (Nice 2024) support the need for accurate assay performance. The Alinity ci system is part of a unified family of systems that are engineered for flexibility, efficiency, and decreased system down time. The design is based on insights from customers, resulting in a number of benefits including a smaller footprint, improved workflow, and great throughput with up to 200 tests per hour. The objective of this study is to demonstrate the analytical performance of representative assays from the Vitamin Panel of the Alinity i system, which consists of assays that utilize photometric technology for the quantitative determination of analytes in human serum or plasma. Methods Key performance testing including precision, limit of quantitation (LoQ), endogenous interferents, linearity and method comparison were assessed per Clinical and Laboratory Standards Institute (CLSI) protocols. Precision was assessed by testing controls and panels twice per day for 20 days on 2 instruments. Sensitivity was determined with 3 reagent lots on 2 instruments. Endogenous compounds were evaluated at a minimum of one analyte concentration. Linearity was assessed using a minimum of 6 panels that spanned the measuring interval. Method comparison was performed by measuring a minimum of 100 specimens on Alinity and the comparator method. The assay measuring interval was defined by the range for which acceptable performance for bias, imprecision, and linearity was met. Results The observed results for precision were 4.1 to 9%. Alinity method comparison vs ARCHITECT demonstrated slopes of 0.95 to 1.04 with correlation coefficients of 0.96 to 1.00. All assays demonstrated equivalent sensitivities, linearity, interferents and measuring intervals to ARCHITECT. Conclusion Standardization of the Abbott assays ensures the assays meet current guidelines. The vitamin panel of assays on the Abbott Alinity i platform demonstrated acceptable performance for precision, sensitivity, interferents and linearity. Method comparison data showed equivalency with the on-market assays, which verified the performance of these products on the Alinity i system.
期刊介绍:
Clinical Chemistry is a peer-reviewed scientific journal that is the premier publication for the science and practice of clinical laboratory medicine. It was established in 1955 and is associated with the Association for Diagnostics & Laboratory Medicine (ADLM).
The journal focuses on laboratory diagnosis and management of patients, and has expanded to include other clinical laboratory disciplines such as genomics, hematology, microbiology, and toxicology. It also publishes articles relevant to clinical specialties including cardiology, endocrinology, gastroenterology, genetics, immunology, infectious diseases, maternal-fetal medicine, neurology, nutrition, oncology, and pediatrics.
In addition to original research, editorials, and reviews, Clinical Chemistry features recurring sections such as clinical case studies, perspectives, podcasts, and Q&A articles. It has the highest impact factor among journals of clinical chemistry, laboratory medicine, pathology, analytical chemistry, transfusion medicine, and clinical microbiology.
The journal is indexed in databases such as MEDLINE and Web of Science.