{"title":"X-configuration Pipeline Flex embolization device for complex anterior communicating artery aneurysm: illustrative case.","authors":"Hao Zhu, Yang Wang, Yunpei Liu, Yingang Wu, Ge Gao","doi":"10.3171/CASE25415","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Complex anterior communicating artery (ACoA) aneurysms involving bilateral anterior cerebral arteries present significant challenges for stent-assisted coiling (SAC). Flow diversion (FD) devices offer a viable alternative for managing such anatomically complex lesions.</p><p><strong>Observations: </strong>An adult patient with a complex 11.21 × 14.28-mm ACoA aneurysm involving bilateral A1-A2 segments underwent FD using two Pipeline Flex embolization devices) deployed in an X-configuration. Conventional clipping or SAC was deemed unsuitable due to anatomical complexity. Postprocedural imaging demonstrated optimal device positioning with contrast retention within the aneurysm sac.</p><p><strong>Lessons: </strong>Follow-up at 3-month and 18-month intervals confirmed complete occlusion with favorable vascular remodeling and without complications, demonstrating the safety and efficacy of this strategy for anatomically challenging aneurysms. https://thejns.org/doi/10.3171/CASE25415.</p>","PeriodicalId":94098,"journal":{"name":"Journal of neurosurgery. Case lessons","volume":"10 13","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12477892/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurosurgery. Case lessons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3171/CASE25415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Complex anterior communicating artery (ACoA) aneurysms involving bilateral anterior cerebral arteries present significant challenges for stent-assisted coiling (SAC). Flow diversion (FD) devices offer a viable alternative for managing such anatomically complex lesions.

Observations: An adult patient with a complex 11.21 × 14.28-mm ACoA aneurysm involving bilateral A1-A2 segments underwent FD using two Pipeline Flex embolization devices) deployed in an X-configuration. Conventional clipping or SAC was deemed unsuitable due to anatomical complexity. Postprocedural imaging demonstrated optimal device positioning with contrast retention within the aneurysm sac.

Lessons: Follow-up at 3-month and 18-month intervals confirmed complete occlusion with favorable vascular remodeling and without complications, demonstrating the safety and efficacy of this strategy for anatomically challenging aneurysms. https://thejns.org/doi/10.3171/CASE25415.

x位管道Flex栓塞装置治疗复杂前交通动脉瘤:举例说明。
背景:累及双侧大脑前动脉的复杂前交通动脉(ACoA)动脉瘤是支架辅助卷绕(SAC)的重大挑战。分流(FD)装置为处理这种解剖复杂的病变提供了可行的选择。观察:一名成年患者患有复杂的11.21 × 14.28 mm ACoA动脉瘤,累及双侧A1-A2段,使用两个Pipeline Flex栓塞装置在x位部署进行FD。由于解剖复杂性,传统的夹持或SAC被认为是不合适的。术后影像显示最佳装置定位,对比剂保留在动脉瘤囊内。经验:间隔3个月和18个月的随访证实了完全闭塞,血管重构良好,无并发症,证明了该策略对解剖挑战性动脉瘤的安全性和有效性。https://thejns.org/doi/10.3171/CASE25415。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信