Successful percutaneous closure of ventricular septal defects associated with pulmonary hypertension using different atrial septal defect Occluders: A report of two cases

Q4 Medicine
José Luis Colín-Ortiz MD , Rogelio Zúñiga-Gordillo MD , Linda Fabiola Pérez-Pérez MD , Carlos Balcázar-Ochoa MD , Roberto Tepatzi-Carranco MD , Rosa María García-Mejía MD
{"title":"Successful percutaneous closure of ventricular septal defects associated with pulmonary hypertension using different atrial septal defect Occluders: A report of two cases","authors":"José Luis Colín-Ortiz MD ,&nbsp;Rogelio Zúñiga-Gordillo MD ,&nbsp;Linda Fabiola Pérez-Pérez MD ,&nbsp;Carlos Balcázar-Ochoa MD ,&nbsp;Roberto Tepatzi-Carranco MD ,&nbsp;Rosa María García-Mejía MD","doi":"10.1016/j.jccase.2025.06.010","DOIUrl":null,"url":null,"abstract":"<div><div><span>We present two cases of children with muscular ventricular septal defects (mVSD) and severe pulmonary hypertension. Both children successfully underwent percutaneous closure using different atrial septal occluder devices. The patients were a 7-month-old boy with growth failure and </span>cyanosis<span><span>, and a 4-year-old boy with heart murmur and mild cyanosis. Their management was based on percutaneous defect closure using an Amplatzer septal occluder; Abbott Structural Heart, Plymouth, MN, USA and an Occlutech Figulla Flex-II occluder; Occlutech GmbH, Jena, Germany, respectively. </span>Atrial septal defect occluder devices are feasible for the closure of large or atypical mVSD associated with pulmonary hypertension.</span></div></div><div><h3>Learning objective</h3><div>Information in the literature shows a brief and no clear evidence about the primary closure of congenital mVSD with atrial septal occluder devices in pediatric patients. This brief report demonstrates that this approach is a safe and effective alternative for the treatment of mVSD cases associated with pulmonary hypertension using different atrial septal occluder devices.</div></div>","PeriodicalId":52092,"journal":{"name":"Journal of Cardiology Cases","volume":"32 4","pages":"Pages 171-174"},"PeriodicalIF":0.0000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiology Cases","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S187854092500060X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

We present two cases of children with muscular ventricular septal defects (mVSD) and severe pulmonary hypertension. Both children successfully underwent percutaneous closure using different atrial septal occluder devices. The patients were a 7-month-old boy with growth failure and cyanosis, and a 4-year-old boy with heart murmur and mild cyanosis. Their management was based on percutaneous defect closure using an Amplatzer septal occluder; Abbott Structural Heart, Plymouth, MN, USA and an Occlutech Figulla Flex-II occluder; Occlutech GmbH, Jena, Germany, respectively. Atrial septal defect occluder devices are feasible for the closure of large or atypical mVSD associated with pulmonary hypertension.

Learning objective

Information in the literature shows a brief and no clear evidence about the primary closure of congenital mVSD with atrial septal occluder devices in pediatric patients. This brief report demonstrates that this approach is a safe and effective alternative for the treatment of mVSD cases associated with pulmonary hypertension using different atrial septal occluder devices.
使用不同的房间隔缺损封堵器成功经皮关闭与肺动脉高压相关的室间隔缺损:两例报告
我们报告了两例儿童肌性室间隔缺损(mVSD)和严重的肺动脉高压。两名儿童都成功地采用不同的房间隔封堵器进行了经皮闭锁。患者是一名7个月大的男孩,患有生长衰竭和紫绀;一名4岁的男孩,患有心脏杂音和轻度紫绀。他们的治疗是基于使用Amplatzer鼻中隔闭塞器经皮缺损封闭;Abbott structure Heart, Plymouth, MN, USA和Occlutech Figulla Flex-II闭塞器;Occlutech GmbH,分别位于德国耶拿。房间隔缺损封堵器是可行的关闭大或不典型mVSD合并肺动脉高压。学习目的:文献资料显示,在儿科患者中,使用房间隔封堵器对先天性mVSD进行初步封闭的证据并不明确。这篇简短的报道表明,使用不同的房间隔封堵器治疗肺动脉高压相关的mVSD病例是一种安全有效的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Cardiology Cases
Journal of Cardiology Cases Medicine-Cardiology and Cardiovascular Medicine
CiteScore
0.90
自引率
0.00%
发文量
177
审稿时长
59 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信