{"title":"Establishment of diagnostic reference levels for quality control in panoramic radiography at public hospitals in Cyprus.","authors":"Vasileios I Metaxas, Georgiana Kokona, Stavros Savvakis, Antonis Evgeniou, Demetris Kaolis","doi":"10.1093/rpd/ncaf108","DOIUrl":null,"url":null,"abstract":"<p><p>Diagnostic reference levels (DRLs) help optimize panoramic radiography by balancing patient dose and image quality. Cyprus lacks national DRLs, highlighting the need to establish local DRLs (LDRLs) within State Health Services Organization (SHSO) hospitals as a part of quality assurance program. This study assessed imaging conditions for paediatric and adult patients undergoing panoramic radiography at SHSO hospitals to determine LDRLs. Patient data (age, sex), hospital location, exposure parameters, and dose area product (DAP) were extracted from the central PACS using the DOSE (Qaelum NV, Belgium) management system. Radiographs were acquired with four panoramic units at Nicosia General Hospital (NGH), Limassol General Hospital (LiGH), Larnaca General Hospital (LaGH), and Famagusta General Hospital (FGH). Third quartile DAP values were defined as LDRLs for paediatric (< 18 years) and adult (≥ 18 years) groups. DAP and exposure conditions were analysed based on hospital and sex groups. LDRLs were also compared with published reference values. The LDRLs were 116 mGycm2 for paediatric and 119 mGycm2 for adult patients. Mean DAP was significantly lower in paediatric patients (p < .001), although the decrease is relatively small (4%). Tube voltage was significantly higher in adults (p < .001). Significant inter-hospital differences in DAP and exposure parameters were observed (p < .001), with the highest doses recorded at LaGH due to elevated tube voltage and current. Adult males showed higher DAP than females (p < .05); in paediatric patients, significant sex-based differences were observed at NGH and in total dataset. SHSO DAP values were generally higher, except at LiGH and NGH that were comparable to or lower than those in the international literature. This study established LDRLs for panoramic radiography in Cyprus' public hospitals, filling a critical gap in national radiation protection data and supporting legal compliance. The LDRLs may serve as baseline for optimizing dental radiographic practices within the SHSO. Higher DAP compared to international data suggest a need for enhanced dose optimization, particularly in paediatric imaging. Significant inter-hospital differences in DAP and exposure parameters, despite standardized equipment and protocols, highlighting the need for further standardization and quality improvement.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":" ","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2025-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncaf108","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Diagnostic reference levels (DRLs) help optimize panoramic radiography by balancing patient dose and image quality. Cyprus lacks national DRLs, highlighting the need to establish local DRLs (LDRLs) within State Health Services Organization (SHSO) hospitals as a part of quality assurance program. This study assessed imaging conditions for paediatric and adult patients undergoing panoramic radiography at SHSO hospitals to determine LDRLs. Patient data (age, sex), hospital location, exposure parameters, and dose area product (DAP) were extracted from the central PACS using the DOSE (Qaelum NV, Belgium) management system. Radiographs were acquired with four panoramic units at Nicosia General Hospital (NGH), Limassol General Hospital (LiGH), Larnaca General Hospital (LaGH), and Famagusta General Hospital (FGH). Third quartile DAP values were defined as LDRLs for paediatric (< 18 years) and adult (≥ 18 years) groups. DAP and exposure conditions were analysed based on hospital and sex groups. LDRLs were also compared with published reference values. The LDRLs were 116 mGycm2 for paediatric and 119 mGycm2 for adult patients. Mean DAP was significantly lower in paediatric patients (p < .001), although the decrease is relatively small (4%). Tube voltage was significantly higher in adults (p < .001). Significant inter-hospital differences in DAP and exposure parameters were observed (p < .001), with the highest doses recorded at LaGH due to elevated tube voltage and current. Adult males showed higher DAP than females (p < .05); in paediatric patients, significant sex-based differences were observed at NGH and in total dataset. SHSO DAP values were generally higher, except at LiGH and NGH that were comparable to or lower than those in the international literature. This study established LDRLs for panoramic radiography in Cyprus' public hospitals, filling a critical gap in national radiation protection data and supporting legal compliance. The LDRLs may serve as baseline for optimizing dental radiographic practices within the SHSO. Higher DAP compared to international data suggest a need for enhanced dose optimization, particularly in paediatric imaging. Significant inter-hospital differences in DAP and exposure parameters, despite standardized equipment and protocols, highlighting the need for further standardization and quality improvement.

为塞浦路斯公立医院全景放射摄影质量控制建立诊断参考水平。
诊断参考水平(drl)有助于通过平衡患者剂量和图像质量来优化全景放射摄影。塞浦路斯缺乏国家医疗记录,因此需要在国家卫生服务组织(SHSO)医院内建立地方医疗记录,作为质量保证方案的一部分。本研究评估了在SHSO医院接受全景x线摄影的儿童和成人患者的成像条件,以确定ldrl。使用dose (Qaelum NV,比利时)管理系统从中央PACS中提取患者数据(年龄、性别)、医院位置、暴露参数和剂量面积积(DAP)。在尼科西亚总医院(NGH)、利马索尔总医院(light)、拉纳卡总医院(LaGH)和法马古斯塔总医院(FGH)的四个全景单元获得了x光片。第三个四分位数DAP值被定义为儿童(< 18岁)和成人(≥18岁)组的ldrl。根据医院和性别分组分析DAP和暴露条件。ldrl也与已发表的参考值进行了比较。儿童患者的LDRLs为116 mGycm2,成人患者为119 mGycm2。儿科患者的平均DAP显著低于对照组(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiation protection dosimetry
Radiation protection dosimetry 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
1.40
自引率
10.00%
发文量
223
审稿时长
6-12 weeks
期刊介绍: Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信