Evaluating Optical Coherence Tomography and X-Ray Computed Tomography to Measure Tablet Film Coat Thickness.

IF 5.5 3区 医学 Q1 PHARMACOLOGY & PHARMACY
Emily Sanchez, Trent Eastman, Jennifer Potter, Robert Meyer
{"title":"Evaluating Optical Coherence Tomography and X-Ray Computed Tomography to Measure Tablet Film Coat Thickness.","authors":"Emily Sanchez, Trent Eastman, Jennifer Potter, Robert Meyer","doi":"10.3390/pharmaceutics17091225","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objective:</b> Film coatings are vital components of many pharmaceutical products consumed orally in solid dosage form, and the optimization of the film coating unit operation is critical to the success of these products. It is essential to maintain adequate film coat thickness on tablets to ensure the elegance, mechanical integrity, and controlled-release functionality of active pharmaceutical ingredients. We aim to evaluate techniques for measuring the film coat thickness of tablets in the pharmaceutical drug product development space as current research primarily focuses on in-line methods at the manufacturing scale. <b>Methods:</b> A total of four tablet types, varying in size, shape, and coating thickness were assessed using Optical Coherence Tomography and X-ray Computed Tomography. The data was then compared to baseline reference values gathered by examining tablets with a Confocal Microscope. A second trial was performed using an alternative Optical Coherence Tomography instrument to verify the accuracy of the data. The methods were also evaluated on additional criteria utilizing a Pugh Matrix. <b>Results</b>: The initial Optical Coherence Tomography yielded measurements that were inconsistent with the values provided by the control for three of the four tablet types; however, the follow-up study provided values within an acceptable range. The X-ray Computed Tomography also provided accurate measurements but presented challenges for precision in relation to the instrument's resolution capabilities. Based on the assessment of selected criteria, Optical Coherence Tomography is ideal for all clear-coated tablets, while X-ray Computed Tomography is better suited for small tablets with either opaque or clear coats. <b>Conclusions:</b> Optical Coherence Tomography, X-ray Computed Tomography, and the use of a Confocal Microscope are all viable methods for measuring the film coat thickness of tablets. Method selection is not absolute and depends on factors such as safety, ease of use, adaptability, and tablet characteristics. The results of this study will help provide guidance for selecting the most appropriate method for measuring the film coat thickness of a specific tablet.</p>","PeriodicalId":19894,"journal":{"name":"Pharmaceutics","volume":"17 9","pages":""},"PeriodicalIF":5.5000,"publicationDate":"2025-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473543/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/pharmaceutics17091225","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Background/Objective: Film coatings are vital components of many pharmaceutical products consumed orally in solid dosage form, and the optimization of the film coating unit operation is critical to the success of these products. It is essential to maintain adequate film coat thickness on tablets to ensure the elegance, mechanical integrity, and controlled-release functionality of active pharmaceutical ingredients. We aim to evaluate techniques for measuring the film coat thickness of tablets in the pharmaceutical drug product development space as current research primarily focuses on in-line methods at the manufacturing scale. Methods: A total of four tablet types, varying in size, shape, and coating thickness were assessed using Optical Coherence Tomography and X-ray Computed Tomography. The data was then compared to baseline reference values gathered by examining tablets with a Confocal Microscope. A second trial was performed using an alternative Optical Coherence Tomography instrument to verify the accuracy of the data. The methods were also evaluated on additional criteria utilizing a Pugh Matrix. Results: The initial Optical Coherence Tomography yielded measurements that were inconsistent with the values provided by the control for three of the four tablet types; however, the follow-up study provided values within an acceptable range. The X-ray Computed Tomography also provided accurate measurements but presented challenges for precision in relation to the instrument's resolution capabilities. Based on the assessment of selected criteria, Optical Coherence Tomography is ideal for all clear-coated tablets, while X-ray Computed Tomography is better suited for small tablets with either opaque or clear coats. Conclusions: Optical Coherence Tomography, X-ray Computed Tomography, and the use of a Confocal Microscope are all viable methods for measuring the film coat thickness of tablets. Method selection is not absolute and depends on factors such as safety, ease of use, adaptability, and tablet characteristics. The results of this study will help provide guidance for selecting the most appropriate method for measuring the film coat thickness of a specific tablet.

评价光学相干断层扫描和x射线计算机断层扫描测量片剂薄膜涂层厚度。
背景/目的:膜包衣是许多口服固体剂型药品的重要组成部分,膜包衣单元操作的优化对这些产品的成功至关重要。在片剂上保持足够的膜层厚度,以确保活性药物成分的美观性、机械完整性和控释功能是必不可少的。由于目前的研究主要集中在生产规模的在线方法上,我们的目标是评估在制药产品开发领域测量片剂薄膜涂层厚度的技术。方法:采用光学相干断层扫描和x射线计算机断层扫描对四种不同大小、形状和涂层厚度的片剂进行评估。然后将数据与用共聚焦显微镜检查片剂收集的基线参考值进行比较。第二次试验使用另一种光学相干断层扫描仪器来验证数据的准确性。利用Pugh矩阵对这些方法进行了附加标准评估。结果:四种片剂中有三种的初始光学相干层析成像结果与对照组提供的值不一致;然而,后续研究提供的数值在可接受的范围内。x射线计算机断层扫描也提供了精确的测量,但与仪器的分辨率能力相关的精度提出了挑战。根据所选标准的评估,光学相干断层扫描是所有透明涂层片剂的理想选择,而x射线计算机断层扫描更适合于不透明或透明涂层的小片剂。结论:光学相干断层扫描、x线计算机断层扫描和共聚焦显微镜是测定片剂膜被厚度的可行方法。方法选择不是绝对的,取决于安全性、易用性、适应性和片剂特性等因素。本研究的结果将有助于指导选择最合适的方法来测量特定片剂的膜层厚度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pharmaceutics
Pharmaceutics Pharmacology, Toxicology and Pharmaceutics-Pharmaceutical Science
CiteScore
7.90
自引率
11.10%
发文量
2379
审稿时长
16.41 days
期刊介绍: Pharmaceutics (ISSN 1999-4923) is an open access journal which provides an advanced forum for the science and technology of pharmaceutics and biopharmaceutics. It publishes reviews, regular research papers, communications,  and short notes. Covered topics include pharmacokinetics, toxicokinetics, pharmacodynamics, pharmacogenetics and pharmacogenomics, and pharmaceutical formulation. Our aim is to encourage scientists to publish their experimental and theoretical details in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信