Reference Intervals and Cut-Off Values for Thyroid Tests in the Croatian Adult Population on the Snibe MAGLUMI X6 Immunoassay Analyzer.

IF 3.3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Ivana Lapić, Dragana Šegulja, Željkica Jakoplić, Iva Lukić, Dunja Rogić
{"title":"Reference Intervals and Cut-Off Values for Thyroid Tests in the Croatian Adult Population on the Snibe MAGLUMI X6 Immunoassay Analyzer.","authors":"Ivana Lapić, Dragana Šegulja, Željkica Jakoplić, Iva Lukić, Dunja Rogić","doi":"10.3390/diagnostics15182360","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objectives:</b> To establish reference intervals (RIs) and cut-off values for thyroid-related tests on the MAGLUMI X6 immunoassay analyzer (Snibe Diagnostic, Shenzhen, China) in an adult Croatian population. <b>Methods</b>: This study included 305 healthy individuals who underwent regular preventive medical checkup. The following tests were determined in serum: thyroid-stimulating hormone (TSH), total triiodothyronine (TT3), total thyroxine (TT4), free triiodothyronine (FT3), free thyroxine (FT4), thyroglobulin (Tg), reverse triiodothyronine (revT3), total binding capacity of thyroglobulin (T-uptake), thyroglobulin antibodies (anti-Tg), anti-thyroid peroxidase antibodies (anti-TPO) and thyroid receptor antibodies (TRAb). TSH, TT3, TT4, FT3, FT4, Tg, revT3 and T-uptake results were used for calculating double-sided 95% RIs between the 2.5th and 97.5th percentiles. For anti-Tg, anti-TPO and TRAb, right-sided cut-offs that correspond to the 95th percentile were determined. <b>Results</b>: Reference intervals for TSH, TT4, FT3, FT4, Tg, T-uptake and revT3 did not differ by gender (<i>p</i> > 0.05) and were 0.77-5.04 mIU/L, 69.9-127.7 nmol/L, 3.84-6.20 pmol/L, 13.8-19.7 pmol/L, 1.8-51.2 µg/L, 0.9-1.2 TBI and 0.44-0.73 ng/mL, respectively. The RI for TT3 was different for males (1.49-2.53 nmol/L) and females (1.43-2.81 nmol/L), <i>p</i> = 0.021. A single cut-off for anti-TPO was established (<18 kIU/L). Differences in cut-offs for males and females were obtained for anti-Tg (<72 and <104 kIU/L, respectively) and TRAb (0.6 and 0.9 IU/L, respectively). <b>Conclusions</b>: This is the first study to determine RIs for thyroid function tests in Croatian adults on the Snibe analytical platform. The obtained results point out to the use of population- and immunoassay-specific RIs. For TT3, anti-Tg and TRAb gender-specific RIs should be considered.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"15 18","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12468744/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics15182360","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background/Objectives: To establish reference intervals (RIs) and cut-off values for thyroid-related tests on the MAGLUMI X6 immunoassay analyzer (Snibe Diagnostic, Shenzhen, China) in an adult Croatian population. Methods: This study included 305 healthy individuals who underwent regular preventive medical checkup. The following tests were determined in serum: thyroid-stimulating hormone (TSH), total triiodothyronine (TT3), total thyroxine (TT4), free triiodothyronine (FT3), free thyroxine (FT4), thyroglobulin (Tg), reverse triiodothyronine (revT3), total binding capacity of thyroglobulin (T-uptake), thyroglobulin antibodies (anti-Tg), anti-thyroid peroxidase antibodies (anti-TPO) and thyroid receptor antibodies (TRAb). TSH, TT3, TT4, FT3, FT4, Tg, revT3 and T-uptake results were used for calculating double-sided 95% RIs between the 2.5th and 97.5th percentiles. For anti-Tg, anti-TPO and TRAb, right-sided cut-offs that correspond to the 95th percentile were determined. Results: Reference intervals for TSH, TT4, FT3, FT4, Tg, T-uptake and revT3 did not differ by gender (p > 0.05) and were 0.77-5.04 mIU/L, 69.9-127.7 nmol/L, 3.84-6.20 pmol/L, 13.8-19.7 pmol/L, 1.8-51.2 µg/L, 0.9-1.2 TBI and 0.44-0.73 ng/mL, respectively. The RI for TT3 was different for males (1.49-2.53 nmol/L) and females (1.43-2.81 nmol/L), p = 0.021. A single cut-off for anti-TPO was established (<18 kIU/L). Differences in cut-offs for males and females were obtained for anti-Tg (<72 and <104 kIU/L, respectively) and TRAb (0.6 and 0.9 IU/L, respectively). Conclusions: This is the first study to determine RIs for thyroid function tests in Croatian adults on the Snibe analytical platform. The obtained results point out to the use of population- and immunoassay-specific RIs. For TT3, anti-Tg and TRAb gender-specific RIs should be considered.

克罗地亚成年人群在Snibe MAGLUMI X6免疫分析分析仪上甲状腺测试的参考区间和截止值
背景/目的:在克罗地亚成年人群中建立MAGLUMI X6免疫分析分析仪(Snibe诊断公司,中国深圳)甲状腺相关检测的参考区间(RIs)和临界值。方法:本研究纳入305名定期进行预防性体检的健康个体。测定血清中促甲状腺激素(TSH)、总三碘甲状腺原氨酸(TT3)、总甲状腺素(TT4)、游离三碘甲状腺原氨酸(FT3)、游离甲状腺素(FT4)、甲状腺球蛋白(Tg)、逆三碘甲状腺原氨酸(revT3)、甲状腺球蛋白总结合能力(t摄取)、甲状腺球蛋白抗体(抗Tg)、抗甲状腺过氧化物酶抗体(抗tpo)和甲状腺受体抗体(TRAb)。TSH、TT3、TT4、FT3、FT4、Tg、revT3和t摄取结果用于计算2.5 - 97.5%之间的双侧95% RIs。对于抗tg,抗tpo和TRAb,确定了对应于第95百分位数的右侧截止值。结果:TSH、TT4、FT3、FT4、Tg、t -摄取和revT3的参考区间在0.77 ~ 5.04 mIU/L、69.9 ~ 127.7 nmol/L、3.84 ~ 6.20 pmol/L、13.8 ~ 19.7 pmol/L、1.8 ~ 51.2µg/L、0.9 ~ 1.2 TBI和0.44 ~ 0.73 ng/mL之间无性别差异(p < 0.05)。TT3的RI在雄性(1.49 ~ 2.53 nmol/L)和雌性(1.43 ~ 2.81 nmol/L)之间差异显著,p = 0.021。结论:这是首个在Snibe分析平台上确定克罗地亚成人甲状腺功能测试RIs的研究。获得的结果指出了群体特异性和免疫测定特异性RIs的使用。对于TT3,应考虑抗tg和TRAb性别特异性RIs。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信