Diagnostic de l’amylose cardiaque à TTR par une approche quantitative

IF 0.2 4区 医学 Q4 PATHOLOGY
A. Iep , R. Chequer , V. Algalarrondo , B. Mahida , T. Cabilic , K. Doyeux , F. Rouzet
{"title":"Diagnostic de l’amylose cardiaque à TTR par une approche quantitative","authors":"A. Iep ,&nbsp;R. Chequer ,&nbsp;V. Algalarrondo ,&nbsp;B. Mahida ,&nbsp;T. Cabilic ,&nbsp;K. Doyeux ,&nbsp;F. Rouzet","doi":"10.1016/j.mednuc.2025.04.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>International recommendations for the non-invasive diagnosis of transthyretin cardiac amyloidosis (TTR-CA) rely on visual analysis according to the Perugini 4-point-grading described with planar scintigraphy.</div></div><div><h3>Objective</h3><div>To evaluate the diagnostic performance of quantitative metrics with <sup>99m</sup>Tc-DPD whole-body SPECT/CT for TTR-CA.</div></div><div><h3>Methods</h3><div>Consecutive patients imaged on the Veriton-CT with whole-body <sup>99m</sup>Tc-DPD SPECT/CT were retrospectively analyzed and compared with the TTR-CA diagnosis established by the reference center.</div></div><div><h3>Results</h3><div>One hundred and ninety-four patients were included (47 with TTR-CA) and diagnostic performance of quantitative measure of cardiac amyloid burden normalized to the whole body, was high with an area under the curve (AUC) of 0.956 (95% CI<!--> <!-->=<!--> <!-->[0.916; 0.995]), a sensitivity of 87.2%, and a specificity of 93.2%; comparable to Perugini grading with an AUC of 0.936 (95% CI<!--> <!-->=<!--> <!-->[0.088; 0.984]), a sensitivity of 87.2%, and a specificity of 100%.</div></div><div><h3>Conclusion</h3><div>Semi-automated quantitative analysis with whole-body <sup>99m</sup>Tc-DPD SPECT/CT is not inferior to Perugini visual analysis for the diagnosis of ATTR-CA.</div></div>","PeriodicalId":49841,"journal":{"name":"Medecine Nucleaire-Imagerie Fonctionnelle et Metabolique","volume":"49 5","pages":"Pages 267-277"},"PeriodicalIF":0.2000,"publicationDate":"2025-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medecine Nucleaire-Imagerie Fonctionnelle et Metabolique","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S092812582500261X","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background

International recommendations for the non-invasive diagnosis of transthyretin cardiac amyloidosis (TTR-CA) rely on visual analysis according to the Perugini 4-point-grading described with planar scintigraphy.

Objective

To evaluate the diagnostic performance of quantitative metrics with 99mTc-DPD whole-body SPECT/CT for TTR-CA.

Methods

Consecutive patients imaged on the Veriton-CT with whole-body 99mTc-DPD SPECT/CT were retrospectively analyzed and compared with the TTR-CA diagnosis established by the reference center.

Results

One hundred and ninety-four patients were included (47 with TTR-CA) and diagnostic performance of quantitative measure of cardiac amyloid burden normalized to the whole body, was high with an area under the curve (AUC) of 0.956 (95% CI = [0.916; 0.995]), a sensitivity of 87.2%, and a specificity of 93.2%; comparable to Perugini grading with an AUC of 0.936 (95% CI = [0.088; 0.984]), a sensitivity of 87.2%, and a specificity of 100%.

Conclusion

Semi-automated quantitative analysis with whole-body 99mTc-DPD SPECT/CT is not inferior to Perugini visual analysis for the diagnosis of ATTR-CA.
心脏淀粉样蛋白TTR定量诊断
国际推荐的经甲状腺素型心脏淀粉样变性(TTR-CA)的无创诊断依赖于平面闪烁显像描述的Perugini 4点分级的视觉分析。目的评价99mTc-DPD全身SPECT/CT定量指标对TTR-CA的诊断价值。方法回顾性分析连续患者在verton -CT和全身99mTc-DPD SPECT/CT上的影像,并与参考中心建立的TTR-CA诊断进行比较。结果纳入194例患者(47例为TTR-CA),曲线下面积(AUC)为0.956 (95% CI =[0.916; 0.995]),灵敏度为87.2%,特异性为93.2%;与Perugini分级相当,AUC为0.936 (95% CI =[0.088; 0.984]),敏感性为87.2%,特异性为100%。结论全身99mTc-DPD SPECT/CT半自动化定量分析对atr - ca的诊断不低于Perugini目视分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.30
自引率
0.00%
发文量
160
审稿时长
19.8 weeks
期刊介绍: Le but de Médecine nucléaire - Imagerie fonctionnelle et métabolique est de fournir une plate-forme d''échange d''informations cliniques et scientifiques pour la communauté francophone de médecine nucléaire, et de constituer une expérience pédagogique de la rédaction médicale en conformité avec les normes internationales.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信