Intraoperative optical coherence tomography-guided compression sutures in acute corneal hydrops - Surgical technique and review of literature.

IF 1.8 4区 医学 Q2 OPHTHALMOLOGY
Manpreet Kaur, Akshaya Balaji, Jeewan S Titiyal, Manvi Bansal, Rishav Raj, Vaibhav Namdev
{"title":"Intraoperative optical coherence tomography-guided compression sutures in acute corneal hydrops - Surgical technique and review of literature.","authors":"Manpreet Kaur, Akshaya Balaji, Jeewan S Titiyal, Manvi Bansal, Rishav Raj, Vaibhav Namdev","doi":"10.4103/IJO.IJO_2795_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To describe outcomes of the intraoperative optical coherence tomography (iOCT)-guided technique of partial-thickness compression sutures (PTS) in acute corneal hydrops. We also provide a comprehensive review of literature of the outcomes of compression sutures in acute hydrops.</p><p><strong>Methods: </strong>This study involves prospective interventional case series of patients with keratoconus and acute corneal hydrops. iOCT was used to assess the morphological features of the hydrops, observe surgical dynamics during PTS, titrate the magnitude of suture tightness by observing the stromal compaction and minimisation of intrastromal fluid clefts, and confirm the depth of suture placement (intended at 50-60%). The primary outcome measure was time to resolution of hydrops. Suture removal was planned after documenting stability of corneal thickness.</p><p><strong>Results: </strong>Seven patients (4 males, 3 females; median age 16 years) underwent iOCT-guided PTS with intracameral air. The time interval between onset of hydrops and PTS ranged from 1 to 12 weeks. The preoperative corneal thickness ranged from 1120 to 2363 mm. The initial depth of suture placement on iOCT was observed to be <50%; progressive stromal compaction and collapse of intrastromal fluid pockets allowed deeper penetration with needle during subsequent suture placement. A decrease in separation of DM from stroma was noted; however, no case had on-table complete DM-stromal reattachment. Complete resolution of hydrops was observed by 2 weeks in all cases. Suture removal was performed in 5 cases at 8-12 weeks.</p><p><strong>Conclusion: </strong>iOCT helps titrate depth and tightness of compression sutures in real time to achieve on-table stromal compaction and minimization of intrastromal clefts, with fast resolution of acute hydrops.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_2795_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To describe outcomes of the intraoperative optical coherence tomography (iOCT)-guided technique of partial-thickness compression sutures (PTS) in acute corneal hydrops. We also provide a comprehensive review of literature of the outcomes of compression sutures in acute hydrops.

Methods: This study involves prospective interventional case series of patients with keratoconus and acute corneal hydrops. iOCT was used to assess the morphological features of the hydrops, observe surgical dynamics during PTS, titrate the magnitude of suture tightness by observing the stromal compaction and minimisation of intrastromal fluid clefts, and confirm the depth of suture placement (intended at 50-60%). The primary outcome measure was time to resolution of hydrops. Suture removal was planned after documenting stability of corneal thickness.

Results: Seven patients (4 males, 3 females; median age 16 years) underwent iOCT-guided PTS with intracameral air. The time interval between onset of hydrops and PTS ranged from 1 to 12 weeks. The preoperative corneal thickness ranged from 1120 to 2363 mm. The initial depth of suture placement on iOCT was observed to be <50%; progressive stromal compaction and collapse of intrastromal fluid pockets allowed deeper penetration with needle during subsequent suture placement. A decrease in separation of DM from stroma was noted; however, no case had on-table complete DM-stromal reattachment. Complete resolution of hydrops was observed by 2 weeks in all cases. Suture removal was performed in 5 cases at 8-12 weeks.

Conclusion: iOCT helps titrate depth and tightness of compression sutures in real time to achieve on-table stromal compaction and minimization of intrastromal clefts, with fast resolution of acute hydrops.

术中光学相干层析引导下的急性角膜积液压缩缝合术-手术技术及文献回顾。
目的:探讨术中光学相干断层扫描(iOCT)引导下部分厚度压缩缝合(PTS)治疗急性角膜积液的效果。我们也提供了一个全面的文献综述的结果压缩缝合在急性积液。方法:对圆锥角膜合并急性角膜积液患者进行前瞻性介入治疗。使用iOCT评估积液的形态学特征,观察PTS过程中的手术动态,通过观察基质压实和基质内液裂最小化来滴定缝合紧密程度,并确认缝合放置深度(拟在50-60%)。主要观察指标为水肿消退的时间。在记录角膜厚度的稳定性后,计划拆除缝线。结果:7例患者(男性4例,女性3例,中位年龄16岁)接受了颅内腔内空气引导下的颅内腔内穿刺治疗。水肿与PTS发作的时间间隔为1 ~ 12周。术前角膜厚度为1120 ~ 2363 mm。结论:iOCT有助于实时滴定压缩缝线的深度和紧密度,实现表上基质压实,最大限度地减少基质内裂,快速解决急性积液。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信