{"title":"Influence of Drying Condition and Other Aspects on Recovery of <i>Pseudomonas aeruginosa</i> in the PN-EN 14561 Carrier Test.","authors":"Agnieszka Chojecka","doi":"10.33073/pjm-2025-034","DOIUrl":null,"url":null,"abstract":"<p><p><i>Pseudomonas aeruginosa</i> is a bacterium sensitive to desiccation. Its use in disinfectant testing methods is important given its association with hospital-acquired infections. According to PNEN 14561:2008, obtaining a sufficient number of <i>P. aeruginosa</i> cells on a glass test surface under clean conditions after the drying process is essential for evaluating the bactericidal effectiveness of disinfectants. Does reducing the drying temperature of glass carriers contaminated with <i>P. aeruginosa</i> under clean conditions from the standard-recommended 37°C ± 1°C to 24°C ± 1°C improve bacterial recovery after drying? The recovery of <i>P. aeruginosa</i> from glass surfaces after drying was performed by the procedure specified for the water control, as outlined in PN-EN 14561:2008. Additionally, in the 24°C ± 1°C, the glass carriers were inoculated onto TSA medium, whereas at 37 °C ± 1°C the number of <i>P. aeruginosa</i> was determined in hard water following the contact time. The mean recovery of <i>P. aeruginosa</i> (6.37 log ± 0.12 log) was significantly higher in the 24°C ± 1°C variant compared to the 37°C ± 1°C variant (5.60 log ± 0.24 log). At 24°C ± 1°C, <i>P. aeruginosa</i> remained on the glass carrier after recovery, whereas at 37°C ± 1°C, the bacteria were detected in hard water. Lowering the drying temperature did not allow recovery of <i>P. aeruginosa</i> at the level required by PN-EN 14561:2008. The reduction in <i>P. aeruginosa</i> recovery resulted from bacterial detachment into hard water and retention on the carrier surface.</p>","PeriodicalId":94173,"journal":{"name":"Polish journal of microbiology","volume":"74 3","pages":"401-406"},"PeriodicalIF":1.6000,"publicationDate":"2025-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12445979/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish journal of microbiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33073/pjm-2025-034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Pseudomonas aeruginosa is a bacterium sensitive to desiccation. Its use in disinfectant testing methods is important given its association with hospital-acquired infections. According to PNEN 14561:2008, obtaining a sufficient number of P. aeruginosa cells on a glass test surface under clean conditions after the drying process is essential for evaluating the bactericidal effectiveness of disinfectants. Does reducing the drying temperature of glass carriers contaminated with P. aeruginosa under clean conditions from the standard-recommended 37°C ± 1°C to 24°C ± 1°C improve bacterial recovery after drying? The recovery of P. aeruginosa from glass surfaces after drying was performed by the procedure specified for the water control, as outlined in PN-EN 14561:2008. Additionally, in the 24°C ± 1°C, the glass carriers were inoculated onto TSA medium, whereas at 37 °C ± 1°C the number of P. aeruginosa was determined in hard water following the contact time. The mean recovery of P. aeruginosa (6.37 log ± 0.12 log) was significantly higher in the 24°C ± 1°C variant compared to the 37°C ± 1°C variant (5.60 log ± 0.24 log). At 24°C ± 1°C, P. aeruginosa remained on the glass carrier after recovery, whereas at 37°C ± 1°C, the bacteria were detected in hard water. Lowering the drying temperature did not allow recovery of P. aeruginosa at the level required by PN-EN 14561:2008. The reduction in P. aeruginosa recovery resulted from bacterial detachment into hard water and retention on the carrier surface.

Abstract Image

Abstract Image

pn - en14561载体试验中干燥条件等因素对铜绿假单胞菌回收率的影响
铜绿假单胞菌是一种对干燥敏感的细菌。考虑到它与医院获得性感染的关系,在消毒剂测试方法中使用它很重要。根据PNEN 14561:2008,在干燥过程后的清洁条件下,在玻璃测试表面上获得足够数量的铜绿假单胞菌细胞对于评估消毒剂的杀菌效果至关重要。将被铜绿假单胞菌污染的玻璃载体在清洁条件下的干燥温度从标准推荐的37°C±1°C降低到24°C±1°C是否能提高干燥后的细菌回收率?干燥后从玻璃表面回收铜绿假单胞菌,按照PN-EN 14561:2008中规定的水控制程序进行。另外,在24°C±1°C条件下,将玻璃载体接种到TSA培养基上,而在37°C±1°C条件下,根据接触时间在硬水中测定铜绿假单胞菌的数量。P. aeruginosa在24°C±1°C环境中的平均回收率(6.37 log±0.12 log)显著高于37°C±1°C环境中的平均回收率(5.60 log±0.24 log)。在24°C±1°C时,铜绿假单胞菌恢复后仍停留在玻璃载体上,而在37°C±1°C时,在硬水中检测到细菌。降低干燥温度不能使铜绿假单胞菌的回收率达到PN-EN 14561:2008所要求的水平。铜绿假单胞菌回收率的降低是由于细菌脱离到硬水中并滞留在载体表面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信