{"title":"Evaluation of a Modified Single-Stage Continuous Curvilinear Capsulorhexis Technique Using 18-Gauge Needle Decompression in Intumescent Cataracts.","authors":"Trung Kien Hoang, Huynh Phuc Nguyen, Van Nam Phan","doi":"10.2147/OPTH.S541643","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the safety and efficacy of a modified anterior capsulorhexis technique using an 18-gauge needle puncture at the peripheral one-third of the anterior capsule to control intralenticular pressure and achieve single-stage continuous curvilinear capsulorhexis (CCC) in intumescent cataract surgery.</p><p><strong>Methods: </strong>This prospective, cross-sectional descriptive study included patients with intumescent cataracts indicated for surgery at Saigon Vinh Eye Hospital from August 2024 to March 2025. Before CCC, all patients underwent an 18-gauge needle puncture at the peripheral one-third of the anterior capsule near the main incision.</p><p><strong>Results: </strong>A total of 99 eyes from 99 patients were included in the study. The mean axial length was 23.12 ± 0.55 mm, anterior chamber depth 2.62 ± 0.43 mm, and lens thickness 4.91 ± 0.72 mm. In 65 patients (65.7%), the milky liquefied cortex escaped into the anterior chamber after the needle puncture. Single-stage CCC was successfully performed in 98 of 99 cases (98.9%) with a mean capsulorhexis diameter of 5.5 ± 0.3 mm. All surgeries were performed using standard phacoemulsification and in-the-bag IOL implantation (100%). Three months post-operatively, all patients had well-centered IOLs with a best-corrected visual acuity (BCVA) ≥ 4/10.</p><p><strong>Conclusion: </strong>An 18-gauge needle puncture at the peripheral one-third of the anterior capsule offers effective decompression, improves safety, and facilitates CCC in patients with intumescent cataracts. This technique is simple, feasible, and highly applicable in clinical practice.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":"19 ","pages":"3339-3346"},"PeriodicalIF":0.0000,"publicationDate":"2025-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12435520/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S541643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To evaluate the safety and efficacy of a modified anterior capsulorhexis technique using an 18-gauge needle puncture at the peripheral one-third of the anterior capsule to control intralenticular pressure and achieve single-stage continuous curvilinear capsulorhexis (CCC) in intumescent cataract surgery.
Methods: This prospective, cross-sectional descriptive study included patients with intumescent cataracts indicated for surgery at Saigon Vinh Eye Hospital from August 2024 to March 2025. Before CCC, all patients underwent an 18-gauge needle puncture at the peripheral one-third of the anterior capsule near the main incision.
Results: A total of 99 eyes from 99 patients were included in the study. The mean axial length was 23.12 ± 0.55 mm, anterior chamber depth 2.62 ± 0.43 mm, and lens thickness 4.91 ± 0.72 mm. In 65 patients (65.7%), the milky liquefied cortex escaped into the anterior chamber after the needle puncture. Single-stage CCC was successfully performed in 98 of 99 cases (98.9%) with a mean capsulorhexis diameter of 5.5 ± 0.3 mm. All surgeries were performed using standard phacoemulsification and in-the-bag IOL implantation (100%). Three months post-operatively, all patients had well-centered IOLs with a best-corrected visual acuity (BCVA) ≥ 4/10.
Conclusion: An 18-gauge needle puncture at the peripheral one-third of the anterior capsule offers effective decompression, improves safety, and facilitates CCC in patients with intumescent cataracts. This technique is simple, feasible, and highly applicable in clinical practice.