Comparative effects of continuous glucose monitoring-informed and traditional interval-based carbohydrate refueling protocols on endurance exercise responses: an exploratory study.

IF 3.9 2区 医学 Q1 NUTRITION & DIETETICS
Eric Tsz-Chun Poon, Kin-Wong Lau, Jaclyn Hei Tsang, Xiaoyuan Zhang, Waris Wongpipit
{"title":"Comparative effects of continuous glucose monitoring-informed and traditional interval-based carbohydrate refueling protocols on endurance exercise responses: an exploratory study.","authors":"Eric Tsz-Chun Poon, Kin-Wong Lau, Jaclyn Hei Tsang, Xiaoyuan Zhang, Waris Wongpipit","doi":"10.1080/15502783.2025.2561670","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Recent advancements in Continuous Glucose Monitoring (CGM) technology provide a novel solution for monitoring dynamic glucose fluctuations during endurance exercise, enabling personalized carbohydrate refueling strategies. However, direct evidence demonstrating its superiority over traditional refueling guidelines has been lacking. This exploratory study compared a CGM-informed protocol with a traditional interval-based (TRAD) carbohydrate refueling protocol on endurance exercise responses.</p><p><strong>Methods: </strong>Twelve healthy, non-diabetic males (age = 32.3 ± 6.3 years) participated in two trials involving 75 minutes of continuous cycling at 50% peak power output, with the two carbohydrate refueling protocols implemented in a randomized, crossover order. In the TRAD protocol, participants received standard carbohydrate solutions at regular 15-min intervals, while replenishment timing in the CGM-informed protocol was guided by real-time glucose trends, particularly during declines.</p><p><strong>Results: </strong>No significant differences were observed in heart rate, blood lactate, or perceived exertion between conditions (all p > 0.05). However, CGM-informed protocol displayed a lower coefficient of variation of glucose levels (8.82 ± 4.68%) than the TRAD protocol (11.95 ± 3.41%, Cohen's d  = 0.76, p = 0.013), indicating a steadier blood glucose trend. The mean 75-minute interstitial glucose total area under the curve was significantly lower for the CGM-informed protocol (423.4 ± 39.1 mmol·min·L-1), compared to the TRAD protocol (448.6 ± 38.2 mmol·min·L-1, Cohen's d = 0.65, p = 0.008).</p><p><strong>Conclusion: </strong>While the CGM-informed protocol did not demonstrate beneficial effects on physiological responses over the TRAD protocol, it may aid in stabilizing glucose levels during prolonged endurance exercise. Further research is warranted to explore the applications of personalized carbohydrate refueling strategy based on CGM technology on athletic performance across various exercise protocols.   .</p>","PeriodicalId":17400,"journal":{"name":"Journal of the International Society of Sports Nutrition","volume":"22 1","pages":"2561670"},"PeriodicalIF":3.9000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12466181/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the International Society of Sports Nutrition","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/15502783.2025.2561670","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/16 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"NUTRITION & DIETETICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Recent advancements in Continuous Glucose Monitoring (CGM) technology provide a novel solution for monitoring dynamic glucose fluctuations during endurance exercise, enabling personalized carbohydrate refueling strategies. However, direct evidence demonstrating its superiority over traditional refueling guidelines has been lacking. This exploratory study compared a CGM-informed protocol with a traditional interval-based (TRAD) carbohydrate refueling protocol on endurance exercise responses.

Methods: Twelve healthy, non-diabetic males (age = 32.3 ± 6.3 years) participated in two trials involving 75 minutes of continuous cycling at 50% peak power output, with the two carbohydrate refueling protocols implemented in a randomized, crossover order. In the TRAD protocol, participants received standard carbohydrate solutions at regular 15-min intervals, while replenishment timing in the CGM-informed protocol was guided by real-time glucose trends, particularly during declines.

Results: No significant differences were observed in heart rate, blood lactate, or perceived exertion between conditions (all p > 0.05). However, CGM-informed protocol displayed a lower coefficient of variation of glucose levels (8.82 ± 4.68%) than the TRAD protocol (11.95 ± 3.41%, Cohen's d  = 0.76, p = 0.013), indicating a steadier blood glucose trend. The mean 75-minute interstitial glucose total area under the curve was significantly lower for the CGM-informed protocol (423.4 ± 39.1 mmol·min·L-1), compared to the TRAD protocol (448.6 ± 38.2 mmol·min·L-1, Cohen's d = 0.65, p = 0.008).

Conclusion: While the CGM-informed protocol did not demonstrate beneficial effects on physiological responses over the TRAD protocol, it may aid in stabilizing glucose levels during prolonged endurance exercise. Further research is warranted to explore the applications of personalized carbohydrate refueling strategy based on CGM technology on athletic performance across various exercise protocols.   .

连续血糖监测与传统间歇碳水化合物补充方案对耐力运动反应的比较效果:一项探索性研究。
背景:持续血糖监测(CGM)技术的最新进展为监测耐力运动期间的动态血糖波动提供了一种新的解决方案,从而实现个性化的碳水化合物补充策略。然而,一直缺乏直接证据证明其优于传统的加油指南。这项探索性研究比较了基于cgm的方案与传统基于间歇(TRAD)的碳水化合物补充方案对耐力运动反应的影响。方法:12名健康的非糖尿病男性(年龄= 32.3±6.3岁)参加了两项试验,以50%的峰值功率连续骑行75分钟,两种碳水化合物补充方案按随机交叉顺序实施。在TRAD方案中,参与者每隔15分钟定期接受标准碳水化合物溶液,而在cgm通知方案中,补充时间由实时血糖趋势指导,特别是在下降期间。结果:两组患者的心率、血乳酸、劳累感均无显著差异(p < 0.05)。然而,cgm方案的血糖水平变异系数(8.82±4.68%)低于TRAD方案(11.95±3.41%,Cohen’s d = 0.76, p = 0.013),表明血糖趋势更稳定。与TRAD方案(448.6±38.2 mmol·min·L-1, Cohen’s d = 0.65, p = 0.008)相比,cgm方案的平均75分钟间质葡萄糖曲线下总面积(423.4±39.1 mmol·min·L-1)显著降低。结论:与TRAD方案相比,cgm方案没有显示出对生理反应的有益影响,但它可能有助于稳定长时间耐力运动期间的血糖水平。基于CGM技术的个性化碳水化合物补充策略在不同运动方案中的应用值得进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of the International Society of Sports Nutrition
Journal of the International Society of Sports Nutrition NUTRITION & DIETETICS-SPORT SCIENCES
CiteScore
8.80
自引率
3.90%
发文量
34
审稿时长
6-12 weeks
期刊介绍: Journal of the International Society of Sports Nutrition (JISSN) focuses on the acute and chronic effects of sports nutrition and supplementation strategies on body composition, physical performance and metabolism. JISSN is aimed at researchers and sport enthusiasts focused on delivering knowledge on exercise and nutrition on health, disease, rehabilitation, training, and performance. The journal provides a platform on which readers can determine nutritional strategies that may enhance exercise and/or training adaptations leading to improved health and performance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信