[Performance evaluation of an acridinium ester-based chemiluminescence assay for heparin-binding protein and its application in the diagnosis of sepsis].
Y Y Wang, S J Yu, Q Chen, B C Zhan, K Chen, G Q Chen, L B Hong, J G Wu
{"title":"[Performance evaluation of an acridinium ester-based chemiluminescence assay for heparin-binding protein and its application in the diagnosis of sepsis].","authors":"Y Y Wang, S J Yu, Q Chen, B C Zhan, K Chen, G Q Chen, L B Hong, J G Wu","doi":"10.3760/cma.j.cn112150-20250523-00469","DOIUrl":null,"url":null,"abstract":"<p><p>This study aims to comprehensively evaluate the analytical performance and clinical application value of an acridinium ester-based chemiluminescence assay for detecting heparin-binding protein (HBP), providing more accurate laboratory evidence for the early diagnosis of infections and sepsis. The analytical performance of the HBP detection kit based on acridinium ester chemiluminescence was verified in Hangzhou Hospital of Traditional Chinese Medicine in January 2024 to June 2024, including limit of blank (LoB), accuracy, precision, linear range, anti-interference ability, and clinical diagnostic concordance. The potential of this assay in early diagnosis and treatment monitoring of sepsis was assessed. HBP levels were measured in 97 patients with sepsis and 160 healthy controls, and intergroup differences were analyzed using the Mann-Whitney <i>U</i> test. The results showed that the LoB of the HBP detection kit based on acridinium ester chemiluminescence was 0.10 RLU, and low-concentration sample testing showed good discrimination. In the accuracy evaluation, the regression equation between the test reagent and the comparator was <i>y</i>=1.015 2<i>x</i>-2.850 8 (R²=0.995 1). For precision, the CV in intra-assay was ≤3.51%, and the CV in inter-assay was ≤4.18%. Within the linear range of 0.42-493.46 ng/ml, the regression equation was <i>y</i>=0.996 9<i>x</i>+3.066 0 (R²=0.999 1). In interference experiments, the relative deviation was <3%. Clinically, the median HBP concentration in the sepsis group (median: 121.1 ng/ml) was significantly higher than in the control group (median: 6.3 ng/ml, <i>P</i><0.000 1), with a diagnostic sensitivity of 98.97% and specificity of 96.25%. Age stratification had no effect on HBP levels (<i>U=</i>448<i>,P</i>=0.780 0). In conclusion,the acridinium ester-based chemiluminescence assay requires only about 10 minutes to complete the detection and deliver results, demonstrating acceptable sensitivity, precision, and anti-interference capability. Its wide linear range and rapid detection meet emergency testing needs. Clinical validation confirms HBP's extremely high sensitivity and specificity for sepsis diagnosis, supporting its role as a key marker for early diagnosis, treatment monitoring, and prognosis assessment.</p>","PeriodicalId":24033,"journal":{"name":"中华预防医学杂志","volume":"59 9","pages":"1546-1551"},"PeriodicalIF":0.0000,"publicationDate":"2025-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华预防医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112150-20250523-00469","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
This study aims to comprehensively evaluate the analytical performance and clinical application value of an acridinium ester-based chemiluminescence assay for detecting heparin-binding protein (HBP), providing more accurate laboratory evidence for the early diagnosis of infections and sepsis. The analytical performance of the HBP detection kit based on acridinium ester chemiluminescence was verified in Hangzhou Hospital of Traditional Chinese Medicine in January 2024 to June 2024, including limit of blank (LoB), accuracy, precision, linear range, anti-interference ability, and clinical diagnostic concordance. The potential of this assay in early diagnosis and treatment monitoring of sepsis was assessed. HBP levels were measured in 97 patients with sepsis and 160 healthy controls, and intergroup differences were analyzed using the Mann-Whitney U test. The results showed that the LoB of the HBP detection kit based on acridinium ester chemiluminescence was 0.10 RLU, and low-concentration sample testing showed good discrimination. In the accuracy evaluation, the regression equation between the test reagent and the comparator was y=1.015 2x-2.850 8 (R²=0.995 1). For precision, the CV in intra-assay was ≤3.51%, and the CV in inter-assay was ≤4.18%. Within the linear range of 0.42-493.46 ng/ml, the regression equation was y=0.996 9x+3.066 0 (R²=0.999 1). In interference experiments, the relative deviation was <3%. Clinically, the median HBP concentration in the sepsis group (median: 121.1 ng/ml) was significantly higher than in the control group (median: 6.3 ng/ml, P<0.000 1), with a diagnostic sensitivity of 98.97% and specificity of 96.25%. Age stratification had no effect on HBP levels (U=448,P=0.780 0). In conclusion,the acridinium ester-based chemiluminescence assay requires only about 10 minutes to complete the detection and deliver results, demonstrating acceptable sensitivity, precision, and anti-interference capability. Its wide linear range and rapid detection meet emergency testing needs. Clinical validation confirms HBP's extremely high sensitivity and specificity for sepsis diagnosis, supporting its role as a key marker for early diagnosis, treatment monitoring, and prognosis assessment.
期刊介绍:
Chinese Journal of Preventive Medicine (CJPM), the successor to Chinese Health Journal , was initiated on October 1, 1953. In 1960, it was amalgamated with the Chinese Medical Journal and the Journal of Medical History and Health Care , and thereafter, was renamed as People’s Care . On November 25, 1978, the publication was denominated as Chinese Journal of Preventive Medicine . The contents of CJPM deal with a wide range of disciplines and technologies including epidemiology, environmental health, nutrition and food hygiene, occupational health, hygiene for children and adolescents, radiological health, toxicology, biostatistics, social medicine, pathogenic and epidemiological research in malignant tumor, surveillance and immunization.