{"title":"Conversion coefficients and air density correction factors for new operational quantities in monoenergetic photon calibration fields.","authors":"Tomoya Tsuji, Hiroshi Yoshitomi, Sho Nishino, Fuminobu Sato, Yoshihiko Tanimura","doi":"10.1088/1361-6498/ae0597","DOIUrl":null,"url":null,"abstract":"<p><p>In response to the new operational quantities proposed in ICRU Report 95, we calculated conversion coefficients for monoenergetic photon calibration fields-specifically, the<sup>241</sup>Am<i>γ</i>-ray calibration field and the fluorescence x-ray calibration field-both of which are listed in the annex of the ISO 4037 standard series. These coefficients were derived using the measured photon fluence spectrum. Additionally, correction factors for air density were determined for the low-energy fluorescence x-ray calibration field. Both the conversion coefficients and the air density correction factors were found to vary within the standard uncertainty specified by the ISO 4037 series.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ae0597","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
In response to the new operational quantities proposed in ICRU Report 95, we calculated conversion coefficients for monoenergetic photon calibration fields-specifically, the241Amγ-ray calibration field and the fluorescence x-ray calibration field-both of which are listed in the annex of the ISO 4037 standard series. These coefficients were derived using the measured photon fluence spectrum. Additionally, correction factors for air density were determined for the low-energy fluorescence x-ray calibration field. Both the conversion coefficients and the air density correction factors were found to vary within the standard uncertainty specified by the ISO 4037 series.
期刊介绍:
Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments.
The journal encourages publication of data and code as well as results.