Repeatability of diffusion-weighted arterial spin labeling MRI for mapping blood-brain barrier water exchange rate at different postlabel delays.

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Yufei D Zhu, Quimby N Lee, Xingfeng Shao, Youngkyoo Jung, Danny J J Wang, Audrey P Fan
{"title":"Repeatability of diffusion-weighted arterial spin labeling MRI for mapping blood-brain barrier water exchange rate at different postlabel delays.","authors":"Yufei D Zhu, Quimby N Lee, Xingfeng Shao, Youngkyoo Jung, Danny J J Wang, Audrey P Fan","doi":"10.1002/mrm.70081","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study sought to determine the intrasession repeatability of the diffusion-weighted (DW) arterial spin labeling (ASL) sequence at different postlabel delays (PLDs).</p><p><strong>Methods: </strong>We first performed numerical simulations to study the accuracy of the two-compartment water exchange rate (Kw) fitting model with added Gaussian noise for DW PLDs at 1500, 1800, and 2100 ms. Ten young, healthy participants then underwent a structural T<sub>1</sub> scan and two intrasession in vivo DW ASL scans at each PLD on a 3T MRI. The Kw, arterial transit time (ATT), and cerebral blood flow maps were linearly registered to the structural images, which were then segmented using FreeSurfer into masks with 35 bilateral gray-matter regions.</p><p><strong>Results: </strong>Simulation results showed that the Kw fitting model performed at an error rate less than 10% at physiological ATTs and Kw values, but that error and bias increased at a PLD of 2100 ms and at ATT ranges where the overall blood signal fraction (A<sub>1</sub>) is low. In vivo analysis showed a significant positive correlation between intrasession measurements of regional Kw at a DW PLD of 1800 ms (β = 0.33, p < 0.001) only. Furthermore, a significant positive relationship between Kw and cerebral blood flow was seen at a DW PLD of 1500 ms (β = 0.26, p = 0.005) and DW PLD of 2100 ms (β = 0.39, p = 0.006).</p><p><strong>Conclusion: </strong>Overall, DW ASL provides the strongest intrasession repeatability at a PLD of 1800 ms in young, healthy subjects, and a simulation study shows accurate Kw fits at physiologic range of ATTs and Kw values.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.70081","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study sought to determine the intrasession repeatability of the diffusion-weighted (DW) arterial spin labeling (ASL) sequence at different postlabel delays (PLDs).

Methods: We first performed numerical simulations to study the accuracy of the two-compartment water exchange rate (Kw) fitting model with added Gaussian noise for DW PLDs at 1500, 1800, and 2100 ms. Ten young, healthy participants then underwent a structural T1 scan and two intrasession in vivo DW ASL scans at each PLD on a 3T MRI. The Kw, arterial transit time (ATT), and cerebral blood flow maps were linearly registered to the structural images, which were then segmented using FreeSurfer into masks with 35 bilateral gray-matter regions.

Results: Simulation results showed that the Kw fitting model performed at an error rate less than 10% at physiological ATTs and Kw values, but that error and bias increased at a PLD of 2100 ms and at ATT ranges where the overall blood signal fraction (A1) is low. In vivo analysis showed a significant positive correlation between intrasession measurements of regional Kw at a DW PLD of 1800 ms (β = 0.33, p < 0.001) only. Furthermore, a significant positive relationship between Kw and cerebral blood flow was seen at a DW PLD of 1500 ms (β = 0.26, p = 0.005) and DW PLD of 2100 ms (β = 0.39, p = 0.006).

Conclusion: Overall, DW ASL provides the strongest intrasession repeatability at a PLD of 1800 ms in young, healthy subjects, and a simulation study shows accurate Kw fits at physiologic range of ATTs and Kw values.

弥散加权动脉自旋标记MRI在不同标记后延迟时绘制血脑屏障水交换率的可重复性。
目的:本研究旨在确定扩散加权(DW)动脉自旋标记(ASL)序列在不同标记后延迟(pld)下的分裂内重复性。方法:我们首先通过数值模拟来研究在1500、1800和2100 ms时DW pld加高斯噪声的双室水交换率(Kw)拟合模型的准确性。然后,10名年轻健康的参与者在3T MRI上对每个PLD进行了结构T1扫描和两次体内DW ASL扫描。将Kw、动脉传递时间(ATT)和脑血流图与结构图像线性匹配,然后使用FreeSurfer将结构图像分割成35个双侧灰质区。结果:仿真结果表明,Kw拟合模型在生理ats和Kw值下的错误率小于10%,但在PLD为2100 ms时,在整体血液信号分数(A1)较低的ATT范围内,误差和偏差增加。体内分析显示,在1800 ms的PLD下,DW ASL在年轻健康受试者中提供了最强的PLD重复性,并且模拟研究显示,在ATTs和Kw值的生理范围内,Kw值准确匹配。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信