{"title":"Effect of precipitate formation in the root canal on the accuracy of electronic apex locators.","authors":"Kürşat Er, Simay Koç, Damla Erkal, Dide Tekinarslan, Ömer Kesmez, Feride Demir, Eszther Borbely","doi":"10.2334/josnusd.25-0079","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluated how the formation of various types of precipitates affects the accuracy of electronic apex locators in determining the working length.</p><p><strong>Methods: </strong>Two hundred and forty extracted human maxillary incisors were selected. A total of eight groups were used: four groups (n = 30) for the application of different irrigants; saline, sodium hypochlorite (5.25% NaOCl), chlorhexidine (2% CHX) and ethylenediaminetetraacetic acid (EDTA) (17% EDTA), and four groups (n = 30) for the formation of precipitates; orange-brown (2% CHX + 5.25% NaOCl), orange-white (2%CHX + 0.16% NaOCl), white milky (2% CHX + 17% EDTA), salt (2% CHX + saline). Electronic working length was determined by two different electronic apex locators.</p><p><strong>Results: </strong>The success rate of the 5.25% NaOCl group was significantly higher than that of the white milky precipitate group. The electronic apex locators were highly effective in identifying working length, but the success rate of both devices declined due to the production of a white milky precipitate.</p><p><strong>Conclusion: </strong>The study emphasizes the importance of selecting appropriate irrigation protocols for optimal treatment outcomes, as the chemical interactions between solutions and precipitates significantly influence electronic apex locator measurements, highlighting the need for careful consideration of irrigant compatibility.</p>","PeriodicalId":16646,"journal":{"name":"Journal of oral science","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of oral science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2334/josnusd.25-0079","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study evaluated how the formation of various types of precipitates affects the accuracy of electronic apex locators in determining the working length.

Methods: Two hundred and forty extracted human maxillary incisors were selected. A total of eight groups were used: four groups (n = 30) for the application of different irrigants; saline, sodium hypochlorite (5.25% NaOCl), chlorhexidine (2% CHX) and ethylenediaminetetraacetic acid (EDTA) (17% EDTA), and four groups (n = 30) for the formation of precipitates; orange-brown (2% CHX + 5.25% NaOCl), orange-white (2%CHX + 0.16% NaOCl), white milky (2% CHX + 17% EDTA), salt (2% CHX + saline). Electronic working length was determined by two different electronic apex locators.

Results: The success rate of the 5.25% NaOCl group was significantly higher than that of the white milky precipitate group. The electronic apex locators were highly effective in identifying working length, but the success rate of both devices declined due to the production of a white milky precipitate.

Conclusion: The study emphasizes the importance of selecting appropriate irrigation protocols for optimal treatment outcomes, as the chemical interactions between solutions and precipitates significantly influence electronic apex locator measurements, highlighting the need for careful consideration of irrigant compatibility.

根管内沉淀对电子根尖定位器精度的影响。
目的:评价不同类型沉淀的形成对电子顶点定位仪确定工作长度精度的影响。方法:选择拔除的人上颌切牙240颗。共采用8组:4组(n = 30)分别应用不同的灌洗剂;生理盐水,次氯酸钠(5.25% NaOCl),氯己定(2% CHX)和乙二胺四乙酸(EDTA) (17% EDTA),四组(n = 30)形成沉淀;橙棕色(2%CHX + 5.25% NaOCl),橙白色(2%CHX + 0.16% NaOCl),白色乳白色(2%CHX + 17% EDTA),盐(2%CHX +生理盐水)。电子工作长度由两种不同的电子顶点定位器确定。结果:5.25% NaOCl组的成功率明显高于白色乳状沉淀物组。电子顶点定位器在识别工作长度方面非常有效,但由于产生白色乳状沉淀物,两种装置的成功率都有所下降。结论:该研究强调了选择合适的灌溉方案以获得最佳处理结果的重要性,因为溶液和沉淀物之间的化学相互作用显著影响电子顶点定位器的测量,强调了仔细考虑灌溉兼容性的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of oral science
Journal of oral science DENTISTRY, ORAL SURGERY & MEDICINE-MATERIALS SCIENCE, BIOMATERIALS
CiteScore
3.80
自引率
0.00%
发文量
58
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信