Haptic-Optic Fractures in Yamane Flanged Intrascleral Fixated Lenses: A Case Series.

IF 1.5 Q3 OPHTHALMOLOGY
Journal of Ophthalmic & Vision Research Pub Date : 2025-09-02 eCollection Date: 2025-01-01 DOI:10.18502/jovr.v20.16422
Rina Su, Paras P Shah, Elmira Baghdasaryan, Daniel Zhu, Talia Kaden, Jules Winokur, Isha Cheela
{"title":"Haptic-Optic Fractures in Yamane Flanged Intrascleral Fixated Lenses: A Case Series.","authors":"Rina Su, Paras P Shah, Elmira Baghdasaryan, Daniel Zhu, Talia Kaden, Jules Winokur, Isha Cheela","doi":"10.18502/jovr.v20.16422","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To report five cases of structural weakness at the haptic-optic junction of the CT Lucia 602 intraocular lens (IOL) (Carl Zeiss Meditec Inc., Dublin, CA), including two optic breakages and three optic microfractures, while using the Yamane flanged intrascleral haptic fixation surgery (FIHFS).</p><p><strong>Methods: </strong>A retrospective chart review of five cases that underwent Yamane FIHFS by the same surgeon between 2020 and 2022 was performed. Patients' demographics, operative technique, postoperative outcomes, and adverse events were recorded over a 12-month follow-up period.</p><p><strong>Results: </strong>One case of optic breakage, noted on postoperative week 1 (POW1), had the optic with the trailing haptic suspended in the vitreous while both haptic flanges remained secured to the sclera, requiring IOL exchange. The second case of optic breakage was noted intraoperatively and required explantation of the IOL with subsequent placement of an iris-fixated IOL. Three cases of optic microfractures were observed with no long-term complications. All five fractures occurred at the junction of the leading haptic.</p><p><strong>Conclusion: </strong>Optic breakage and microfractures at the haptic-optic junction are unusual complications of intrascleral fixated IOL using the Yamane technique. To the best of our knowledge, this has not been previously reported with the CT Lucia 602 IOL. The authors recommend careful selection of the IOL material for this technique to prevent possible complications.</p>","PeriodicalId":16586,"journal":{"name":"Journal of Ophthalmic & Vision Research","volume":"20 ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2025-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12415495/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmic & Vision Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/jovr.v20.16422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To report five cases of structural weakness at the haptic-optic junction of the CT Lucia 602 intraocular lens (IOL) (Carl Zeiss Meditec Inc., Dublin, CA), including two optic breakages and three optic microfractures, while using the Yamane flanged intrascleral haptic fixation surgery (FIHFS).

Methods: A retrospective chart review of five cases that underwent Yamane FIHFS by the same surgeon between 2020 and 2022 was performed. Patients' demographics, operative technique, postoperative outcomes, and adverse events were recorded over a 12-month follow-up period.

Results: One case of optic breakage, noted on postoperative week 1 (POW1), had the optic with the trailing haptic suspended in the vitreous while both haptic flanges remained secured to the sclera, requiring IOL exchange. The second case of optic breakage was noted intraoperatively and required explantation of the IOL with subsequent placement of an iris-fixated IOL. Three cases of optic microfractures were observed with no long-term complications. All five fractures occurred at the junction of the leading haptic.

Conclusion: Optic breakage and microfractures at the haptic-optic junction are unusual complications of intrascleral fixated IOL using the Yamane technique. To the best of our knowledge, this has not been previously reported with the CT Lucia 602 IOL. The authors recommend careful selection of the IOL material for this technique to prevent possible complications.

Abstract Image

Abstract Image

Abstract Image

Yamane法兰巩膜内固定晶状体的触觉-视觉骨折:一个病例系列。
目的:报告5例CT Lucia 602人工晶状体(IOL) (Carl Zeiss Meditec Inc., Dublin, CA)在使用Yamane侧翼巩膜内触觉固定手术(FIHFS)时出现的触觉-光学连接处结构薄弱,包括2例视神经断裂和3例视神经微骨折。方法:回顾性分析2020年至2022年间同一外科医生行Yamane FIHFS的5例病例。在12个月的随访期间记录患者的人口统计学、手术技术、术后结果和不良事件。结果:1例视神经断裂,于术后第1周(POW1)记录,视神经与后缘触觉悬吊在玻璃体中,而两个触觉缘仍固定在巩膜上,需要人工晶状体置换。术中发现第二例视神经断裂,需要取出人工晶状体,随后放置虹膜固定人工晶状体。观察3例视神经微骨折,无长期并发症。所有5例骨折均发生在前肢触觉交界处。结论:视神经断裂和触觉-视觉交界处微骨折是采用Yamane技术固定人工晶状体的少见并发症。据我们所知,这在CT Lucia 602人工晶状体中还没有报道过。作者建议仔细选择人工晶状体材料,以防止可能的并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
63
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信