Plasma glucose and HbA1c discrepancy may indicate hemoglobinopathy: a case series.

IF 2.2 4区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Gulru Birce Sonmezoz
{"title":"Plasma glucose and HbA1c discrepancy may indicate hemoglobinopathy: a case series.","authors":"Gulru Birce Sonmezoz","doi":"10.1080/03007995.2025.2557519","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Diabetes Mellitus is a chronic disease characterised by elevated plasma glucose (PG) levels. HbA1c has been widely utilized for diabetes diagnosis. However, certain conditions restrict its use. In such cases, plasma glucose (PG) measurements and self-monitoring blood glucose (SMBG) are recommended. This case series highlights the importance of considering both HbA1c and PG or SMBG in the evaluation of patients with diabetes.</p><p><strong>Case report: </strong>This case series presents three cases of patients with diabetes who exhibited a discrepancy between PG and HbA1c levels. Only one patient demonstrated isolated microcytosis, while the remaining two had completely normal hematologic profiles. Due to this discrepancy, hemoglobin electrophoresis was conducted, revealing various hemoglobinopathies in all cases.</p><p><strong>Conclusion: </strong>For patients with discrepancies between PG levels and HbA1c, we suggest a thorough evaluation that includes consideration of potential hemoglobinopathies. These hemoglobin variants can present with isolated microcytosis or entirely normal hematologic parameters and may lead to falsely low HbA1c values. In cases of discordance between PG and HbA1c, hemoglobin electrophoresis can serve as a valuable diagnostic tool. Identifying hemoglobinopathies before determining treatment regimens can help mitigate the risk of complications from inadequate treatment, and awareness of HbA1c limitations allows clinicians to use both HbA1c and PG/SMBG to optimize diabetes management and minimize the risk of diabetic complications.</p>","PeriodicalId":10814,"journal":{"name":"Current Medical Research and Opinion","volume":" ","pages":"1-5"},"PeriodicalIF":2.2000,"publicationDate":"2025-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Medical Research and Opinion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/03007995.2025.2557519","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Diabetes Mellitus is a chronic disease characterised by elevated plasma glucose (PG) levels. HbA1c has been widely utilized for diabetes diagnosis. However, certain conditions restrict its use. In such cases, plasma glucose (PG) measurements and self-monitoring blood glucose (SMBG) are recommended. This case series highlights the importance of considering both HbA1c and PG or SMBG in the evaluation of patients with diabetes.

Case report: This case series presents three cases of patients with diabetes who exhibited a discrepancy between PG and HbA1c levels. Only one patient demonstrated isolated microcytosis, while the remaining two had completely normal hematologic profiles. Due to this discrepancy, hemoglobin electrophoresis was conducted, revealing various hemoglobinopathies in all cases.

Conclusion: For patients with discrepancies between PG levels and HbA1c, we suggest a thorough evaluation that includes consideration of potential hemoglobinopathies. These hemoglobin variants can present with isolated microcytosis or entirely normal hematologic parameters and may lead to falsely low HbA1c values. In cases of discordance between PG and HbA1c, hemoglobin electrophoresis can serve as a valuable diagnostic tool. Identifying hemoglobinopathies before determining treatment regimens can help mitigate the risk of complications from inadequate treatment, and awareness of HbA1c limitations allows clinicians to use both HbA1c and PG/SMBG to optimize diabetes management and minimize the risk of diabetic complications.

血糖和糖化血红蛋白差异可能提示血红蛋白病:一个病例系列。
糖尿病是一种以血浆葡萄糖(PG)水平升高为特征的慢性疾病。HbA1c已被广泛应用于糖尿病的诊断。然而,某些条件限制了它的使用。在这种情况下,建议测量血浆葡萄糖(PG)和自我监测血糖(SMBG)。本病例系列强调了在评估糖尿病患者时同时考虑HbA1c和PG或SMBG的重要性。病例报告:本病例系列报道了3例糖尿病患者,他们表现出PG和HbA1c水平的差异。只有一名患者表现出孤立的小细胞增多,而其余两名患者的血液学特征完全正常。由于这种差异,我们进行了血红蛋白电泳,发现所有病例都有不同的血红蛋白病变。结论:对于PG水平和HbA1c差异的患者,我们建议进行全面的评估,包括考虑潜在的血红蛋白病变。这些血红蛋白变异可以表现为孤立的小细胞增生或完全正常的血液学参数,并可能导致错误的低HbA1c值。在PG和HbA1c不一致的情况下,血红蛋白电泳可以作为一种有价值的诊断工具。在确定治疗方案之前确定血红蛋白病变可以帮助减轻治疗不充分引起的并发症风险,并且对HbA1c限制的认识使临床医生可以同时使用HbA1c和PG/SMBG来优化糖尿病管理并最大限度地减少糖尿病并发症的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Current Medical Research and Opinion
Current Medical Research and Opinion 医学-医学:内科
CiteScore
4.40
自引率
4.30%
发文量
247
审稿时长
3-8 weeks
期刊介绍: Current Medical Research and Opinion is a MEDLINE-indexed, peer-reviewed, international journal for the rapid publication of original research on new and existing drugs and therapies, Phase II-IV studies, and post-marketing investigations. Equivalence, safety and efficacy/effectiveness studies are especially encouraged. Preclinical, Phase I, pharmacoeconomic, outcomes and quality of life studies may also be considered if there is clear clinical relevance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信