Novel prosthetic medial meniscus restores contact pressures to native values in a meniscectomized canine stifle.

IF 1.3 2区 农林科学 Q2 VETERINARY SCIENCES
Fee M C Fohrmann, Branco S van Minnen, Maximiljan W Krauss, Albert J van der Veen, Marianna A Tryfonidou, Björn P Meij, Tony G van Tienen
{"title":"Novel prosthetic medial meniscus restores contact pressures to native values in a meniscectomized canine stifle.","authors":"Fee M C Fohrmann, Branco S van Minnen, Maximiljan W Krauss, Albert J van der Veen, Marianna A Tryfonidou, Björn P Meij, Tony G van Tienen","doi":"10.1111/vsu.70009","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of this study was to ascertain whether a prosthetic meniscus adapts pressures to native tibial contact pressures in a canine stifle joint after total medial meniscectomy.</p><p><strong>Study design: </strong>Ex vivo biomechanical experimental study.</p><p><strong>Sample population: </strong>Seven cadaveric hindlimbs of seven large-breed dogs.</p><p><strong>Methods: </strong>Cadaveric canine stifles were loaded vertically at 135° of flexion. The peak pressure (PP), mean pressure (MP), and contact area (CA) on the medial and lateral tibial plateaus were measured for the intact stifle, after medial meniscectomy and after implantation of the prosthetic meniscus. Comparisons were made between same parameters in varying conditions, but not in varying compartments.</p><p><strong>Results: </strong>Mean PP and MP increased significantly after medial meniscectomy (6.1 and 2.3 MPa, respectively) relative to those of the native stifle joint (3.5 and 1.0 MPa, respectively), whereas meniscectomy resulted in significantly lower mean CA on the medial tibial plateau (65 mm<sup>2</sup>) compared to the native stifle joint (170 mm<sup>2</sup>). The prosthetic meniscus significantly decreased PP to 3.3 MPa and MP to 1.0 MPa and significantly increased CA to 96 mm<sup>2</sup> relative to the meniscectomized stifle. PP and MP were not statistically different between the native stifle and prosthetic meniscus.</p><p><strong>Conclusion: </strong>The prosthetic meniscus significantly restored tibial contact pressures to normal (native) values in the meniscectomized canine stifle.</p><p><strong>Clinical significance: </strong>A prosthetic meniscus has the potential to restore biomechanical function in the canine stifle with an impaired medial meniscal function.</p>","PeriodicalId":23667,"journal":{"name":"Veterinary Surgery","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vsu.70009","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The aim of this study was to ascertain whether a prosthetic meniscus adapts pressures to native tibial contact pressures in a canine stifle joint after total medial meniscectomy.

Study design: Ex vivo biomechanical experimental study.

Sample population: Seven cadaveric hindlimbs of seven large-breed dogs.

Methods: Cadaveric canine stifles were loaded vertically at 135° of flexion. The peak pressure (PP), mean pressure (MP), and contact area (CA) on the medial and lateral tibial plateaus were measured for the intact stifle, after medial meniscectomy and after implantation of the prosthetic meniscus. Comparisons were made between same parameters in varying conditions, but not in varying compartments.

Results: Mean PP and MP increased significantly after medial meniscectomy (6.1 and 2.3 MPa, respectively) relative to those of the native stifle joint (3.5 and 1.0 MPa, respectively), whereas meniscectomy resulted in significantly lower mean CA on the medial tibial plateau (65 mm2) compared to the native stifle joint (170 mm2). The prosthetic meniscus significantly decreased PP to 3.3 MPa and MP to 1.0 MPa and significantly increased CA to 96 mm2 relative to the meniscectomized stifle. PP and MP were not statistically different between the native stifle and prosthetic meniscus.

Conclusion: The prosthetic meniscus significantly restored tibial contact pressures to normal (native) values in the meniscectomized canine stifle.

Clinical significance: A prosthetic meniscus has the potential to restore biomechanical function in the canine stifle with an impaired medial meniscal function.

新型假体内侧半月板恢复接触压力的本地值在半月板切除犬的膝关节。
目的:本研究的目的是确定在全内侧半月板切除术后,假半月板是否能适应犬膝关节内胫骨接触压力。研究设计:体外生物力学实验研究。样本种群:7只大型犬的尸体后肢。方法:以135°屈曲的角度垂直加载尸体犬节。在完整的膝关节、内侧半月板切除术和假半月板植入后,测量胫骨内侧和外侧平台的峰值压力(PP)、平均压力(MP)和接触面积(CA)。在不同条件下对相同参数进行了比较,但在不同的隔室中没有进行比较。结果:内侧半月板切除术后的平均PP和MP(分别为6.1和2.3 MPa)明显高于原生膝关节(分别为3.5和1.0 MPa),而半月板切除术导致胫骨平台内侧的平均CA (65 mm2)明显低于原生膝关节(170 mm2)。与半月板切除的膝关节相比,假体半月板显著降低PP至3.3 MPa, MP至1.0 MPa, CA显著增加至96 mm2。原生膝关节和人工半月板的PP和MP无统计学差异。结论:半月板假体明显地恢复了半月板切除犬膝关节的胫骨接触压力到正常(自然)值。临床意义:半月板假体有可能恢复内侧半月板功能受损的犬膝关节的生物力学功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary Surgery
Veterinary Surgery 农林科学-兽医学
CiteScore
3.40
自引率
22.20%
发文量
162
审稿时长
8-16 weeks
期刊介绍: Veterinary Surgery, the official publication of the American College of Veterinary Surgeons and European College of Veterinary Surgeons, is a source of up-to-date coverage of surgical and anesthetic management of animals, addressing significant problems in veterinary surgery with relevant case histories and observations. It contains original, peer-reviewed articles that cover developments in veterinary surgery, and presents the most current review of the field, with timely articles on surgical techniques, diagnostic aims, care of infections, and advances in knowledge of metabolism as it affects the surgical patient. The journal places new developments in perspective, encompassing new concepts and peer commentary to help better understand and evaluate the surgical patient.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信