{"title":"Visual Performance and Optical Quality After Implantation of Non-diffractive Enhanced Depth of Focus Intraocular Lenses.","authors":"Alaa M Eldanasoury, Karim Ayesh","doi":"10.3928/1081597X-20250707-08","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate visual and refractive outcomes, visual quality, patient satisfaction, and spectacle independence 3 months after phacoemulsification with bilateral non-diffractive enhanced depth of focus (EDOF) lens implantation.</p><p><strong>Methods: </strong>This study included 68 eyes of 34 consecutive patients, with 51.5% undergoing refractive lens exchange and 48.5% undergoing cataract surgery. Exclusion criteria included previous ocular surgery, corneal higher order aberrations greater than 0.6 μm, and corneal astigmatism greater than 1.50 diopters (D). Mini-monovision of -0.50 D was targeted. Uncorrected and corrected distance visual acuity was measured at 4 m and 66 and 40 cm. Patient satisfaction was assessed using subjective questionnaires. Modulation transfer function, Strehl ratio, and objective depth of focus were measured with ray-tracing.</p><p><strong>Results: </strong>At 3 months, the follow-up rate was 97.1% and mean corrected distance visual acuity at 4 m and 66 and 40 cm was -0.02 ± 0.10, 0.11 ± 0.11, and 0.36 ± 0.13 logarithm of the minimum angle of resolution (logMAR), respectively. Monocular defocus curve was higher than 0.20 logMAR from +1.50 to -1.50 D. Mean Objective Scatter Index score at 3 months was 1.48 ± 0.72; it decreased significantly in eyes with cataract and increased significantly in eyes that had refractive lens exchange (<i>P</i> < .05). Spectacle independence was achieved by 95%, 100%, and 34% patients for far, intermediate, and near distances, respectively; 90% patients reported no photic phenomena. Patients were satisfied with daily life activities not requiring near vision.</p><p><strong>Conclusions: </strong>Bilateral implantation of a non-diffractive EDOF lens resulted in good visual performance at far and intermediate distances, with functional near vision at 3 months postoperatively. Patient satisfaction and spectacle independence were high.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"41 9","pages":"e958-e967"},"PeriodicalIF":3.0000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20250707-08","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate visual and refractive outcomes, visual quality, patient satisfaction, and spectacle independence 3 months after phacoemulsification with bilateral non-diffractive enhanced depth of focus (EDOF) lens implantation.
Methods: This study included 68 eyes of 34 consecutive patients, with 51.5% undergoing refractive lens exchange and 48.5% undergoing cataract surgery. Exclusion criteria included previous ocular surgery, corneal higher order aberrations greater than 0.6 μm, and corneal astigmatism greater than 1.50 diopters (D). Mini-monovision of -0.50 D was targeted. Uncorrected and corrected distance visual acuity was measured at 4 m and 66 and 40 cm. Patient satisfaction was assessed using subjective questionnaires. Modulation transfer function, Strehl ratio, and objective depth of focus were measured with ray-tracing.
Results: At 3 months, the follow-up rate was 97.1% and mean corrected distance visual acuity at 4 m and 66 and 40 cm was -0.02 ± 0.10, 0.11 ± 0.11, and 0.36 ± 0.13 logarithm of the minimum angle of resolution (logMAR), respectively. Monocular defocus curve was higher than 0.20 logMAR from +1.50 to -1.50 D. Mean Objective Scatter Index score at 3 months was 1.48 ± 0.72; it decreased significantly in eyes with cataract and increased significantly in eyes that had refractive lens exchange (P < .05). Spectacle independence was achieved by 95%, 100%, and 34% patients for far, intermediate, and near distances, respectively; 90% patients reported no photic phenomena. Patients were satisfied with daily life activities not requiring near vision.
Conclusions: Bilateral implantation of a non-diffractive EDOF lens resulted in good visual performance at far and intermediate distances, with functional near vision at 3 months postoperatively. Patient satisfaction and spectacle independence were high.
期刊介绍:
The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as:
• Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics”
• Supplemental videos and materials available for many articles
• Access to current articles, as well as several years of archived content
• Articles posted online just 2 months after acceptance.